5 research outputs found

    Mid-peripheral visual field defects in glaucoma

    Get PDF
    R Humphrey automated perimeter was used to measure the peripheral 30 to 60 degrees of vision with mid-peripheral field static threshold targets in 41 recently diagnosed glaucoma or glaucoma suspect eyes and 16 eyes of normal controls. The overall mean defect of the 30-60 degree usual field increased 5.11 decibels in the glaucomatous population when compared to the controls. The individual quadrants of the mid-peripheral field of each glaucoma subject were analyzed and quantitatively compared to the corresponding quadrant mean defect of the controls. The mean defect of the superior and the inferior field of the glaucoma subjects significantly differed from the overall mean defect of the controls. Differences on comparison of quantitative defects in the nasal periphery was less significant. This study suggests that peripheral field testing provides useful information in the detection of glaucoma. It also suggests that the analysis of the overall mean defect offers statistically relevant data upon which to judge whether field defects are pathological or normal

    Anticipation of coincidence in baseball players

    Get PDF
    20 players from Pacific University\u27s baseball team were tested on the Bassin Anticipation Timer to determine if anticipation of coincidence as measured by the Bassin correlates to actual hitting tendencies. Bassin results indicate a non-significant correlation exists between actual batting performance and performance expected from Bassin testing. The Bassin triggering device was also held in three different positions to better mimic bat handling. Analysis indicated that the location and manner in which the trigger device is held and pressed makes no statistically significant difference. However, a significant correlation did exist between Bassin performance and strike percentage. Evidence in this study suggests a new manner in which the Bassin Anticipation Timer may be employed to study, and perhaps improve, baseball players\u27 batting

    Intraperitoneal drain placement and outcomes after elective colorectal surgery: international matched, prospective, cohort study

    Get PDF
    Despite current guidelines, intraperitoneal drain placement after elective colorectal surgery remains widespread. Drains were not associated with earlier detection of intraperitoneal collections, but were associated with prolonged hospital stay and increased risk of surgical-site infections.Background Many surgeons routinely place intraperitoneal drains after elective colorectal surgery. However, enhanced recovery after surgery guidelines recommend against their routine use owing to a lack of clear clinical benefit. This study aimed to describe international variation in intraperitoneal drain placement and the safety of this practice. Methods COMPASS (COMPlicAted intra-abdominal collectionS after colorectal Surgery) was a prospective, international, cohort study which enrolled consecutive adults undergoing elective colorectal surgery (February to March 2020). The primary outcome was the rate of intraperitoneal drain placement. Secondary outcomes included: rate and time to diagnosis of postoperative intraperitoneal collections; rate of surgical site infections (SSIs); time to discharge; and 30-day major postoperative complications (Clavien-Dindo grade at least III). After propensity score matching, multivariable logistic regression and Cox proportional hazards regression were used to estimate the independent association of the secondary outcomes with drain placement. Results Overall, 1805 patients from 22 countries were included (798 women, 44.2 per cent; median age 67.0 years). The drain insertion rate was 51.9 per cent (937 patients). After matching, drains were not associated with reduced rates (odds ratio (OR) 1.33, 95 per cent c.i. 0.79 to 2.23; P = 0.287) or earlier detection (hazard ratio (HR) 0.87, 0.33 to 2.31; P = 0.780) of collections. Although not associated with worse major postoperative complications (OR 1.09, 0.68 to 1.75; P = 0.709), drains were associated with delayed hospital discharge (HR 0.58, 0.52 to 0.66; P < 0.001) and an increased risk of SSIs (OR 2.47, 1.50 to 4.05; P < 0.001). Conclusion Intraperitoneal drain placement after elective colorectal surgery is not associated with earlier detection of postoperative collections, but prolongs hospital stay and increases SSI risk

    Intraperitoneal drain placement and outcomes after elective colorectal surgery: international matched, prospective, cohort study

    Get PDF
    Many surgeons routinely place intraperitoneal drains after elective colorectal surgery. However, enhanced recovery after surgery guidelines recommend against their routine use owing to a lack of clear clinical benefit. This study aimed to describe international variation in intraperitoneal drain placement and the safety of this practice

    Safety and efficacy of intraperitoneal drain placement after emergency colorectal surgery. An international, prospective cohort study

    No full text
    Intraperitoneal drains are often placed during emergency colorectal surgery. However, there is a lack of evidence supporting their use. This study aimed to describe the efficacy and safety of intraperitoneal drain placement after emergency colorectal surgery. Method: COMPlicAted intra-abdominal collectionS after colorectal Surgery (COMPASS) is a prospective, international, cohort study into which consecutive adult patients undergoing emergency colorectal surgery were enrolled (from 3 February 2020 to 8 March 2020). The primary outcome was the rate of intraperitoneal drain placement. Secondary outcomes included rate and time-to-diagnosis of postoperative intraperitoneal collections, rate of surgical site infections (SSIs), time to discharge and 30-day major postoperative complications (Clavien-Dindo III-V). Multivariable logistic and Cox proportional hazards regressions were used to estimate the independent association of the outcomes with drain placement. Results: Some 725 patients (median age 68.0 years; 349 [48.1%] women) from 22 countries were included. The drain insertion rate was 53.7% (389 patients). Following multivariable adjustment, drains were not significantly associated with reduced rates (odds ratio [OR] = 1.56, 95% CI: 0.48-5.02, p = 0.457) or earlier detection (hazard ratio [HR] = 1.07, 95% CI: 0.61-1.90, p = 0.805) of collections. Drains were not significantly associated with worse major postoperative complications (OR = 1.26, 95% CI: 0.67-2.36, p = 0.478), delayed hospital discharge (HR = 1.11, 95% CI: 0.91-1.36, p = 0.303) or increased risk of SSIs (OR = 1.61, 95% CI: 0.87-2.99, p = 0.128). Conclusion: This is the first study investigating placement of intraperitoneal drains following emergency colorectal surgery. The safety and clinical benefit of drains remain uncertain. Equipoise exists for randomized trials to define the safety and efficacy of drains in emergency colorectal surgery
    corecore