382 research outputs found
Worldvolume Superalgebra Of BLG Theory With Nambu-Poisson Structure
Recently it was proposed that the Bagger-Lambert-Gustavsson theory with
Nambu-Poisson structure describes an M5-brane in a three-form flux background.
In this paper we investigate the superalgebra associated with this theory. We
derive the central charges corresponding to M5-brane solitons in 3-form
backgrounds. We also show that double dimensional reduction of the superalgebra
gives rise to the Poisson bracket terms of a non-commutative D4-brane
superalgebra. We provide interpretations of the D4-brane charges in terms of
spacetime intersections.Comment: 23 pages; references added, section 4 clarification
Efficacies of the new Paclitaxel-eluting Coroflex Please™ Stent in percutaneous coronary intervention; comparison of efficacy between Coroflex Please™ and Taxus™ (ECO-PLEASANT) trial: study rationale and design
<p>Abstract</p> <p>Background</p> <p>Previous randomized trials have showed the superiority of Paclitaxel-eluting stent over bare metal stent in angiographic and clinical outcomes. Coroflex Please™ stent is a newly developed drug eluting stent using the Coroflex™ stent platform combined with the drug paclitaxel contained in a polymer coating. PECOPS I trial, one-arm observational study, showed that the clinical and angiographic outcomes of Coroflex Please™ stent were within the range of those of Taxus, the 1<sup>st </sup>generation paclitaxel-eluting stent (PES). However, there have been no studies directly comparing the Coroflex Please™ stent with the Taxus Liberte™ stent that is the newest version of Taxus. Therefore, prospective, randomized trial is required to demonstrate the non-inferiority of Coroflex Please™ stent compared with Taxus Liberte™ stent in a head-to-head manner.</p> <p>Methods</p> <p>In the comparison of Efficacy between COroflex PLEASe™ ANd Taxus™ stent(ECO-PLEASANT) trial, approximately 900 patients are being prospectively and randomly assigned to the either type of Coroflex Please™ stent and Taxus Liberte™ stent via web-based randomization. The primary endpoint is clinically driven target vessel revascularization at 9 months. The secondary endpoints include major cardiac adverse events, target vessel failure, stent thrombosis and angiographic efficacy endpoints.</p> <p>Discussion</p> <p>The ECO-PLEASANT trial is the study not yet performed to directly compare the efficacy and safety of the Coroflex Please™ versus Taxus Liberte™ stent. On the basis of this trial, we will be able to find out whether the Coroflex Please™ stent is non-inferior to Taxus Liberte™ stent or not.</p> <p>Trial registration</p> <p>ClinicalTrials.gov number, NCT00699543.</p
The 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE) trial: study protocol for a randomized controlled trial
<p>Abstract</p> <p>Background</p> <p>Second-generation drug-eluting stents (DES) have raised the bar of clinical performance. These stents are mostly made from cobalt chromium alloy. A newer generation DES has been developed from platinum chromium alloy, but clinical data regarding the efficacy and safety of the platinum chromium-based everolimus-eluting stent (PtCr-EES) is limited, with no comparison data against the cobalt chromium-based zotarolimus-eluting stent (CoCr-ZES). In addition, an antiplatelet regimen is an integral component of medical therapy after percutaneous coronary intervention (PCI). A 1-week duration of doubling the dose of clopidogrel (double-dose antiplatelet therapy (DDAT)) was shown to improve outcome at 1 month compared with conventional dose in acute coronary syndrome (ACS) patients undergoing PCI. However in Asia, including Korea, the addition of cilostazol (triplet antiplatelet therapy (TAT)) is used more commonly than doubling the dose of clopidogrel in high-risk patients.</p> <p>Methods</p> <p>In the 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE) trial, approximately 3,750 patients are being prospectively and randomly assigned in a 2 × 2 factorial design according to the type of stent (PtCr-EES vs CoCr-ZES) and antiplatelet regimen (TAT vs DDAT). The first primary endpoint is target lesion failure at 1 year for the stent comparison, and the second primary endpoint is net clinical outcome at 1 month for comparison of antiplatelet therapy regimen.</p> <p>Discussion</p> <p>The HOST-ASSURE trial is the largest study yet performed to directly compare the efficacy and safety of the PtCr-EES versus CoCr-ZES in an 'all-comers' population. In addition, this study will also compare the clinical outcome of TAT versus DDAT for 1-month post PCI.</p> <p>Trial registration</p> <p>ClincalTrials.gov number <a href="http://www.clinicaltrials.gov/ct2/show/NCT01267734">NCT01267734</a>.</p
Precision measurement of the top quark mass from dilepton events at CDF II
We report a measurement of the top quark mass, M_t, in the dilepton decay
channel of
using an integrated luminosity of 1.0 fb^{-1} of p\bar{p} collisions collected
with the CDF II detector. We apply a method that convolutes a leading-order
matrix element with detector resolution functions to form event-by-event
likelihoods; we have enhanced the leading-order description to describe the
effects of initial-state radiation. The joint likelihood is the product of the
likelihoods from 78 candidate events in this sample, which yields a measurement
of M_{t} = 164.5 \pm 3.9(\textrm{stat.}) \pm 3.9(\textrm{syst.})
\mathrm{GeV}/c^2, the most precise measurement of M_t in the dilepton channel.Comment: 7 pages, 2 figures, version includes changes made prior to
publication by journa
Measurement of the Ratios of Branching Fractions B(Bs -> Ds pi pi pi) / B(Bd -> Dd pi pi pi) and B(Bs -> Ds pi) / B(Bd -> Dd pi)
Using 355 pb^-1 of data collected by the CDF II detector in \ppbar collisions
at sqrt{s} = 1.96 TeV at the Fermilab Tevatron, we study the fully
reconstructed hadronic decays B -> D pi and B -> D pi pi pi. We present the
first measurement of the ratio of branching fractions B(Bs -> Ds pi pi pi) /
B(Bd -> Dd pi pi pi) = 1.05 pm 0.10 (stat) pm 0.22 (syst). We also update our
measurement of B(Bs -> Ds pi) / B(Bd -> Dd pi) to 1.13 pm 0.08 (stat) pm 0.23
(syst) improving the statistical uncertainty by more than a factor of two. We
find B(Bs -> Ds pi) = [3.8 pm 0.3 (stat) pm 1.3 (syst)] \times 10^{-3} and B(Bs
-> Ds pi pi pi) = [8.4 pm 0.8 (stat) pm 3.2 (syst)] \times 10^{-3}.Comment: 7 pages, 2 figure
Cross Section Measurements of High- Dilepton Final-State Processes Using a Global Fitting Method
We present a new method for studying high- dilepton events
(, , ) and simultaneously
extracting the production cross sections of , , and p\bar{p} \to \ztt at a center-of-mass energy of TeV. We perform a likelihood fit to the dilepton data in a parameter
space defined by the missing transverse energy and the number of jets in the
event. Our results, which use of data recorded with the CDF
II detector at the Fermilab Tevatron Collider, are pb, pb, and
\sigma(\ztt) =291^{+50}_{-46} pb.Comment: 20 pages, 2 figures, to be submitted to PRD-R
Measurement of the Dipion Mass Spectrum in X(3872) -> J/Psi Pi+ Pi- Decays
We measure the dipion mass spectrum in X(3872)--> J/Psi Pi+ Pi- decays using
360 pb-1 of pbar-p collisions at 1.96 TeV collected with the CDF II detector.
The spectrum is fit with predictions for odd C-parity (3S1, 1P1, and 3DJ)
charmonia decaying to J/Psi Pi+ Pi-, as well as even C-parity states in which
the pions are from Rho0 decay. The latter case also encompasses exotic
interpretations, such as a D0-D*0Bar molecule. Only the 3S1 and J/Psi Rho
hypotheses are compatible with our data. Since 3S1 is untenable on other
grounds, decay via J/Psi Rho is favored, which implies C=+1 for the X(3872).
Models for different J/Psi-Rho angular momenta L are considered. Flexibility in
the models, especially the introduction of Rho-Omega interference, enable good
descriptions of our data for both L=0 and 1.Comment: 7 pages, 4 figures -- Submitted to Phys. Rev. Let
Top Quark Mass Measurement from Dilepton Events at CDF II with the Matrix-Element Method
We describe a measurement of the top quark mass using events with two charged
leptons collected by the CDF II detector from collisions with TeV at the Fermilab Tevatron. The likelihood in top mass is
calculated for each event by convoluting the leading order matrix element
describing
with detector resolution functions. The presence of background events in the
data sample is modeled using similar calculations involving the matrix elements
for major background processes. In a data sample with integrated luminosity of
340 pb, we observe 33 candidate events and measure This
measurement represents the first application of this method to events with two
charged leptons and is the most precise single measurement of the top quark
mass in this channel.Comment: 21 pages, 14 figure
Search for New Physics in Lepton + Photon + X Events with L=305 pb-1 of ppbar Collisions at roots=1.96 TeV
We present results of a search for anomalous production of events containing
a charged lepton (either electron or muon) and a photon, both with high
transverse momentum, accompanied by additional signatures, X, including missing
transverse energy (MET) and additional leptons and photons. We use the same
kinematic selection criteria as in a previous CDF search, but with a
substantially larger data set, 305 pb-1, a ppbar collision energy of 1.96 TeV,
and the upgraded CDF II detector. We find 42 Lepton+Photon+MET events versus a
standard model expectation of 37.3 +- 5.4 events. The level of excess observed
in Run I, 16 events with an expectation of 7.6 +- 0.7 events (corresponding to
a 2.7 sigma effect), is not supported by the new data. In the signature of
Multi-Lepton+Photon+X we observe 31 events versus an expectation of 23.0 +- 2.7
events. In this sample we find no events with an extra photon or MET and so
find no events like the one ee+gg+MET event observed in Run I.Comment: 7 pages, 3 figures, 1 table. Accepted to PR
Measurement of the Lambda_b Lifetime in Lambda_b --> J/psi Lambda0 in p-pbar Collisions at sqrt(s)=1.96 TeV
We report a measurement of the Lambda_b lifetime in the exclusive decay
Lambda_b --> J/psi Lambda0 in p-pbar collisions at sqrt(s) = 1.96 TeV using an
integrated luminosity of 1.0 fb^{-1} of data collected by the CDF II detector
at the Fermilab Tevatron. Using fully reconstructed decays, we measure
tau(Lambda_b) = 1.593 ^{+0.083}_{-0.078} (stat.) +- 0.033 (syst.) ps. This is
the single most precise measurement of tau(Lambda_b) and is 3.2 sigma higher
than the current world average.Comment: 7 Pages, 2 Figures, 1 Table. Submitted to Phys. Rev. Let
- …