209 research outputs found
Intravascular Ultrasound for Assessment of Residual Coarctation of the Aorta after Balloon Angioplasty in Infants
Intravascular ultrasound (IVUS) has been introduced as an accurate and minimally invasive diagnostic technique for the assessment of vascular anatomy and its abnormalities. We believe that IVUS can be used for clarifying the reasons for failure of balloon angiography in infantile coarctation of the aorta (CoA), because post-balloon angioplasty tearing, intimal flap, thrombosis and pseudoaneurysm of the aorta can be evaluated by IVUS with greater sensitivity and specificity. We aimed to assess the outcome of balloon angioplasty of CoA using angiography as the gold standard and IVUS as a new method in infants, comparing the two techniques for the evaluation of the diameter and area of CoA segment pre- and post-procedure. This cross-sectional study was performed on 18 infants hospitalized with a final diagnosis of CoA. All the infants underwent angiography and were also assessed by IVUS to measure the preoperative and postoperative diameter of the narrow segment in the two anterior�posterior and lateral views. In assessment by IVUS, the mean diameter of the coarctation site increased from 2.10 ± 0.30 mm to 4.50 ± 0.94 mm (P < 0.001). Similarly, the average minimum area of the coarctation level increased from 5.26 ± 1.50 mm2 to 13.77 ± 3.48 mm2 after angioplasty (P < 0.001). Comparing these findings, angiography and IVUS showed a high level of agreement. In the assessment of a dissection flap, there was a high level of agreement between angioplasty and IVUS before the procedure, but IVUS had higher accuracy after the procedure. Our study showed that IVUS was more reliable than angiography in the assessment of residual coarctation. IVUS yielded high sensitivity (58.3) and specificity (100) for discriminating the presence and absence of residual coarctation as well as the need for repeating the procedure. The assessment of coarctation before and after angioplasty procedures in children is possible using the IVUS method, with high accuracy. IVUS can offer greater accuracy than angiography in the evaluation of the coarctation area, detecting tears, dissection and flaps, and assessment of residual coarctation. © 2021, Springer Science+Business Media, LLC, part of Springer Nature
Intravascular Ultrasound for Assessment of Residual Coarctation of the Aorta after Balloon Angioplasty in Infants
Intravascular ultrasound (IVUS) has been introduced as an accurate and minimally invasive diagnostic technique for the assessment of vascular anatomy and its abnormalities. We believe that IVUS can be used for clarifying the reasons for failure of balloon angiography in infantile coarctation of the aorta (CoA), because post-balloon angioplasty tearing, intimal flap, thrombosis and pseudoaneurysm of the aorta can be evaluated by IVUS with greater sensitivity and specificity. We aimed to assess the outcome of balloon angioplasty of CoA using angiography as the gold standard and IVUS as a new method in infants, comparing the two techniques for the evaluation of the diameter and area of CoA segment pre- and post-procedure. This cross-sectional study was performed on 18 infants hospitalized with a final diagnosis of CoA. All the infants underwent angiography and were also assessed by IVUS to measure the preoperative and postoperative diameter of the narrow segment in the two anterior�posterior and lateral views. In assessment by IVUS, the mean diameter of the coarctation site increased from 2.10 ± 0.30 mm to 4.50 ± 0.94 mm (P < 0.001). Similarly, the average minimum area of the coarctation level increased from 5.26 ± 1.50 mm2 to 13.77 ± 3.48 mm2 after angioplasty (P < 0.001). Comparing these findings, angiography and IVUS showed a high level of agreement. In the assessment of a dissection flap, there was a high level of agreement between angioplasty and IVUS before the procedure, but IVUS had higher accuracy after the procedure. Our study showed that IVUS was more reliable than angiography in the assessment of residual coarctation. IVUS yielded high sensitivity (58.3) and specificity (100) for discriminating the presence and absence of residual coarctation as well as the need for repeating the procedure. The assessment of coarctation before and after angioplasty procedures in children is possible using the IVUS method, with high accuracy. IVUS can offer greater accuracy than angiography in the evaluation of the coarctation area, detecting tears, dissection and flaps, and assessment of residual coarctation. © 2021, Springer Science+Business Media, LLC, part of Springer Nature
Boundary Conditions for Elastohydrodynamics of Circular Point Contacts
The paper presents the solution of an elastohydrodynamic point contact condition using inlet and outlet lubricant entrainment with partial counter-flow. The inlet and outlet boundaries are determined using potential flow analysis for the pure rolling of contiguous surfaces. This shows that Swift–Stieber boundary conditions best conform to the observed partial counter-flow at the inlet conjunction, satisfying the compatibility condition. For the outlet region, the same is true when Prandtl–Hopkins boundary conditions are employed. Using these boundary conditions, the predictions conform closely to the measured pressure distribution using a deposited pressure-sensitive micro-transducer in a ball-to-flat race contact. Furthermore, the predicted conjunctional shape closely conforms to the often observed characteristic keyhole conjunction through optical interferometry. The combined numerical–experimental analysis with realistic boundary conditions described here has not hitherto been reported in the literature
Reproductive aspects of the oceanic whitetip shark, Carcharhinus longimanus (Elasmobranchii: Carcharhinidae), in the equatorial and southwestern Atlantic Ocean
The present study sought to study the reproductive biology of the oceanic whitetip shark, Carcharhinus longimanus, in the equatorial and southwestern Atlantic Ocean. A total of 234 specimens were collected as bycatch during pelagic longline fisheries targeting tunas and swordfish, between December 2003 and December 2010. The fishing area was located between latitudes 10N and 35S and longitudes 3E and 40W. Of the 234 individuals sampled, 118 were females (with sizes ranging from 81 to 227 cm TL, total length) and 116 males (ranging from 80 to 242 cm TL). The reproductive stages of the females were classed as immature, mature, preovulatory and pregnant, while males were divided into immature, maturing and mature. The size at maturity for females was estimated at 170.0 cm TL, while that for males was between 170.0 and 190.0 cm TL. Ovarian fecundity ranged from 1 to 10 follicles and uterine fecundity from 1 to 10 embryos. The reproductive cycle of this species is most likely biennial, with parturition occurring once every two years.info:eu-repo/semantics/publishedVersio
Subcellular peptide localization in single identified neurons by capillary microsampling mass spectrometry
Single cell mass spectrometry (MS) is uniquely positioned for the sequencing and identification of peptides in rare cells. Small peptides can take on different roles in subcellular compartments. Whereas some peptides serve as neurotransmitters in the cytoplasm, they can also function as transcription factors in the nucleus. Thus, there is a need to analyze the subcellular peptide compositions in identified single cells. Here, we apply capillary microsampling MS with ion mobility separation for the sequencing of peptides in single neurons of the mollusk Lymnaea stagnalis, and the analysis of peptide distributions between the cytoplasm and nucleus of identified single neurons that are known to express cardioactive Phe-Met-Arg-Phe amide-like (FMRFamide-like) neuropeptides. Nuclei and cytoplasm of Type 1 and Type 2 F group (Fgp) neurons were analyzed for neuropeptides cleaved from the protein precursors encoded by alternative splicing products of the FMRFamide gene. Relative abundances of nine neuropeptides were determined in the cytoplasm. The nuclei contained six of these peptides at different abundances. Enabled by its relative enrichment in Fgp neurons, a new 28-residue neuropeptide was sequenced by tandem MS
Global economic burden of unmet surgical need for appendicitis
Background: There is a substantial gap in provision of adequate surgical care in many low-and middle-income countries. This study aimed to identify the economic burden of unmet surgical need for the common condition of appendicitis. Methods: Data on the incidence of appendicitis from 170 countries and two different approaches were used to estimate numbers of patients who do not receive surgery: as a fixed proportion of the total unmet surgical need per country (approach 1); and based on country income status (approach 2). Indirect costs with current levels of access and local quality, and those if quality were at the standards of high-income countries, were estimated. A human capital approach was applied, focusing on the economic burden resulting from premature death and absenteeism. Results: Excess mortality was 4185 per 100 000 cases of appendicitis using approach 1 and 3448 per 100 000 using approach 2. The economic burden of continuing current levels of access and local quality was US 73 141 million using approach 2. The economic burden of not providing surgical care to the standards of high-income countries was 75 666 million using approach 2. The largest share of these costs resulted from premature death (97.7 per cent) and lack of access (97.0 per cent) in contrast to lack of quality. Conclusion: For a comparatively non-complex emergency condition such as appendicitis, increasing access to care should be prioritized. Although improving quality of care should not be neglected, increasing provision of care at current standards could reduce societal costs substantially
Impact of COVID-19 on vascular patients worldwide: analysis of the COVIDSurg data
BACKGROUND: The COVIDSurg collaborative was an international multicenter prospective analysis of perioperative data from 235 hospitals in 24 countries. It found that perioperative COVID-19 infection was associated with a mortality rate of 24%. At the same time, the COVER study demonstrated similarly high perioperative mortality rates in vascular surgical patients undergoing vascular interventions even without COVID-19, likely associated with the high burden of comorbidity associated with vascular patients. This is a vascular subgroup analysis of the COVIDSurg cohort.
//
METHODS: All patients with a suspected or confirmed diagnosis of COVID-19 in the 7 days prior to, or in the 30 days following a vascular procedure were included. The primary outcome was 30-day mortality. Secondary outcomes were pulmonary complications (adult respiratory distress syndrome, pulmonary embolism, pneumonia and respiratory failure). Logistic regression was undertaken for dichotomous outcomes.
//
RESULTS: Overall, 602 patients were included in this subgroup analysis, of which 88.4% were emergencies. The most common operations performed were for vascular-related dialysis access procedures (20.1%, N.=121). The combined 30-day mortality rate was 27.2%. Composite secondary pulmonary outcomes occurred in half of the vascular patients (N.=275, 45.7%).
//
CONCLUSIONS: Mortality following vascular surgery in COVID positive patients was significantly higher than levels reported pre-pandemic, and similar to that seen in other specialties in the COVIDSurg cohort. Initiatives and surgical pathways that ensure vascular patients are protected from exposure to COVID-19 in the peri-operative period are vital to protect against excess mortality
- …