319 research outputs found

    Four left renal arteries — a rare variant of kidney arterial supply

    Get PDF
    We describe the arterial supply of a human kidney harvested post-mortem from a 75-year-old female volunteer body donor. The kidney was analysed with con- trast-enhanced computed tomography (CT), and corrosion casting was used to reveal the kidney’s angio-architecture. In the left kidney, we observed four renal arteries, each originating directly from the abdominal aorta. Three renal arteries, including the main renal artery, coursed through the renal hilum, and the fourth renal artery reached the lower kidney pole. The supply areas of each of the four renal arteries were analysed with a three-dimensional reconstruction of CT images and with corrosion casting. There were no clear boundaries between the areas supplied by the four renal arteries because their branches overlapped in most kidney segments.

    Design and Vertical Tests of SPS-series Double-Quarter Wave (DQW) Cavity Prototypes for the HL-LHC Crab Cavity System

    Full text link
    Crab crossing is essential for high-luminosity colliders. The High Luminosity Large Hadron Collider (HL-LHC) will equip one of its Interaction Points (IP1) with Double-Quarter Wave (DQW) crab cavities. A DQW cavity is a new generation of deflecting RF cavities that stands out for its compactness and broad frequency separation between fundamental and first high-order modes. The deflecting kick is provided by its fundamental mode. Each HL-LHC DQW cavity shall provide a nominal deflecting voltage of 3.4 MV, although up to 5.0 MV may be required. A Proof-of-Principle (PoP) DQW cavity was limited by quench at 4.6 MV. This paper describes a new, highly optimized cavity, designated DQW SPS-series, which satisfies dimensional, cryogenic, manufacturing and impedance requirements for beam tests at SPS and operation in LHC. Two prototypes of this DQW SPS-series were fabricated by US industry and cold tested after following conventional SRF surface treatment. Both units outperformed the PoP cavity, reaching a deflecting voltage of 5.3-5.9 MV. This voltage - the highest reached by a DQW cavity - is well beyond the nominal voltage of 3.4 MV and may even operate at the ultimate voltage of 5.0MVwith sufficient margin. This paper covers fabrication, surface preparation and cryogenic RF test results and implications

    MRI of the lung (3/3)-current applications and future perspectives

    Get PDF
    BACKGROUND: MRI of the lung is recommended in a number of clinical indications. Having a non-radiation alternative is particularly attractive in children and young subjects, or pregnant women. METHODS: Provided there is sufficient expertise, magnetic resonance imaging (MRI) may be considered as the preferential modality in specific clinical conditions such as cystic fibrosis and acute pulmonary embolism, since additional functional information on respiratory mechanics and regional lung perfusion is provided. In other cases, such as tumours and pneumonia in children, lung MRI may be considered an alternative or adjunct to other modalities with at least similar diagnostic value. RESULTS: In interstitial lung disease, the clinical utility of MRI remains to be proven, but it could provide additional information that will be beneficial in research, or at some stage in clinical practice. Customised protocols for chest imaging combine fast breath-hold acquisitions from a "buffet" of sequences. Having introduced details of imaging protocols in previous articles, the aim of this manuscript is to discuss the advantages and limitations of lung MRI in current clinical practice. CONCLUSION: New developments and future perspectives such as motion-compensated imaging with self-navigated sequences or fast Fourier decomposition MRI for non-contrast enhanced ventilation- and perfusion-weighted imaging of the lung are discussed. Main Messages • MRI evolves as a third lung imaging modality, combining morphological and functional information. • It may be considered first choice in cystic fibrosis and pulmonary embolism of young and pregnant patients. • In other cases (tumours, pneumonia in children), it is an alternative or adjunct to X-ray and CT. • In interstitial lung disease, it serves for research, but the clinical value remains to be proven. • New users are advised to make themselves familiar with the particular advantages and limitations

    Reliability, Validity and Responsiveness of the Syncope Functional Status Questionnaire

    Get PDF
    BACKGROUND: Patients with transient loss of consciousness (TLOC) have poor health-related quality of life (HR-QoL). OBJECTIVE: To test the reliability, validity, and responsiveness of the disease-specific Syncope Functional Status HR-QoL Questionnaire (SFSQ), which yields two summary scales--impairment score (IS) and fear-worry score (FWS). DESIGN: Cohort-study. PARTICIPANTS: 503 adult patients presenting with TLOC. MEASUREMENTS: HR-QoL was assessed using the SFSQ and the Short Form-36 (SF-36) after presentation and 1 year later. To test reliability, score distributions, internal consistency, and test-retest reliability were assessed. To assess validity, scores on the SFSQ and the SF-36 were compared. Clinical validity was tested using known-group comparison. Responsiveness was assessed by comparing changes in SFSQ scores with changes in health status and clinical condition. RESULTS: Response rate was 82% at baseline and 72% at 1-year follow-up. For all scales the full range of scores was seen. Score distributions were asymmetrical. Internal consistency was high (alpha = 0.88 for IS, 0.92 for FWS). Test-retest reliability was moderate to good for individual items and high for summary scales (inter-class correlation = 0.78 for both IS and FWS). Correlations between SFSQ scores and the SF-36 were modest. The SFSQ did not discriminate between patients differing in age and gender but did discriminate between patients differing in number of episodes and comorbid conditions. Changes in SFSQ scores were related to changes in health status and the presence of recurrences but did not vary by TLOC diagnosis. CONCLUSION: The SFSQ is an adequately reliable, valid, and responsive measure to assess HR-QoL in patients with TLO

    Development of SRF Cavity Tuners for CERN

    Get PDF
    Superconducting RF cavity developments are currently on-going for new accelerator projects at CERN such as HIE ISOLDE and HL-LHC. Mechanical RF tuning systems are required to compensate cavity frequency shifts of the cavities due to temperature, mechanical, pressure and RF effects on the cavity geometry. A rich history and experience is available for such mechanical tuners developed for existing RF cavities. Design constraints in the context of HIE ISOLDE and HL-LHC such as required resolution, space limitation, reliability and maintainability have led to new concepts in the tuning mechanisms. This paper will discuss such new approaches, their performances and planned developments

    The design of international dual degree programmes as effective transnational education experiences

    Get PDF
    International Dual Degree (IDD) programmes recently emerged as an attractive transnational education (TNE) opportunity for both prospective students and higher education institutions. Students can experience different education systems, increase their international networks, and ultimately boost their employability. Organizations can develop their international presence, exchange best practices, and exploit efficiencies. Despite their numerous advantages and some distinguished cases of success, IDD programmes remain marginal in the global offer of TNE. Multiple processes intertwine to configure them as complex ventures that often intimidate education managers. The chapter builds on a case study to present decision-makers with a framework for designing and implementing a successful IDD programme. The WHEEL framework aims at equipping education managers with practical signposts for successfully engaging with such strategic opportunity

    The Consumer Quality Index Hip Knee Questionnaire measuring patients' experiences with quality of care after a total hip or knee arthroplasty

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The Dutch Consumer Quality Index Hip Knee Questionnaire (CQI Hip Knee) was used to assess patients' experiences with and evaluations of quality of care after a total hip (THA) or total knee arthroplasty (TKA). The aim of this study is to evaluate the construct validity and internal consistency reliability of this new instrument and to assess its ability to measure differences in quality of care between hospitals.</p> <p>Methods</p> <p>Survey data of 1,675 subjects who underwent a THA or TKA were used to evaluate the psychometric properties. Exploratory factor analyses were performed and item-total correlations and inter-factor correlations were calculated to assess the construct validity of the instrument. Reliability analyses included tests of internal consistency (Cronbach's alpha coefficients). Finally, multilevel analyses were performed to assess the ability of the instrument to discriminate between hospitals in quality of care.</p> <p>Results</p> <p>Exploratory factor analyses indicated that the survey consisted of 21 items measuring five aspects of care (i.e. communication with nurses, communication with doctors, communication with general practitioner, communication about new medication, and pain control). Cronbach's alpha coefficients ranged from 0.76 to 0.90 indicating good internal consistency. The survey's ability to discriminate between hospitals was partly supported by multilevel analysis. Two scales (i.e. communication with nurses and communication with doctors) were able to measure differences between hospitals with respect to patients' experiences with quality of care. Logistic multilevel analyses indicated that hospitals explained part of the variation between patients in receiving information.</p> <p>Conclusion</p> <p>These findings suggest that the CQI Hip Knee is reliable and valid for use in Dutch health care. Health care providers or health plans can use this survey to measure patients' experiences with hospital care and to identify variations in care between hospitals.</p

    Knowledge and training in paediatric medical traumatic stress and trauma-informed care among emergency medical professionals in low- and middle-income countries

    Get PDF
    © 2018, © 2018 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group. Background: Provision of psychosocial care, in particular trauma-informed care, in the immediate aftermath of paediatric injury is a recommended strategy to minimize the risk of paediatric medical traumatic stress. Objective: To examine the knowledge of paediatric medical traumatic stress and perspectives on providing trauma-informed care among emergency staff working in low- and middle-income countries (LMICs). Method: Training status, knowledge of paediatric medical traumatic stress, attitudes towards incorporating psychosocial care and barriers experienced were assessed using an online self-report questionnaire. Respondents included 320 emergency staff from 58 LMICs. Data analyses included descriptive statistics, t-tests and multiple regression. Results: Participating emergency staff working in LMICs had a low level of knowledge of paediatric medical traumatic stress. Ninety-one percent of respondents had not received any training or education in paediatric medical traumatic stress, or trauma-informed care for injured children, while 94% of respondents indicated they wanted training in this area. Conclusions: There appears to be a need for training and education of emergency staff in LMICs regarding paediatric medical traumatic stress and trauma-informed care, in particular among staff working in comparatively lower income countries

    Reduction in Subtypes and Sizes of Myocardial Infarction With Ticagrelor in PEGASUS-TIMI 54

    Get PDF
    Background: Ticagrelor reduced cardiovascular death, myocardial infarction (MI), or stroke in patients with prior MI in PEGASUSTIMI 54 (Prevention of Cardiovascular Events [eg, Death From Heart or Vascular Disease, Heart Attack, or Stroke] in Patients With Prior Heart Attack Using Ticagrelor Compared to Placebo on a Background of Aspirin). MI can occur in diverse settings and with varying severity; therefore, understanding the types and sizes of MI events prevented is of clinical importance. Methods and Results: MIs were adjudicated by a blinded clinical events committee and categorized by subtype and fold elevation of peak cardiac troponin over the upper limit of normal. A total of 1042 MIs occurred in 898 of the 21 162 randomized patients over a median follow-up of 33 months. The majority of the MIs (76%) were spontaneous (Type 1), with demand MI (Type 2) and stent thrombosis (Type 4b) accounting for 13% and 9%, respectively; sudden death (Type 3), percutaneous coronary intervention–related (Type 4a) and coronary artery bypass graft–related (Type 5) each accounted for <1%. Half of MIs (520, 50%) had a peak troponin ≥10x upper limit of normal and 21% of MIs (220) had a peak troponin ≥1009 upper limit of normal. A total of 21% (224) were ST-segment–elevation MI STEMI. Overall ticagrelor reduced MI (4.47% versus 5.25%, hazard ratio 0.83, 95% confidence interval 0.72–0.95, P=0.0055). The benefit was consistent among the subtypes, including a 31% reduction in MIs with a peak troponin ≥1009 upper limit of normal (hazard ratio 0.69, 95% confidence interval 0.53–0.92, P=0.0096) and a 40% reduction in ST-segment elevation MI (hazard ratio 0.60, 95% confidence interval 0.46–0.78, P=0.0002). Conclusions: In stable outpatients with prior MI, the majority of recurrent MIs are spontaneous and associated with a high biomarker elevation. Ticagrelor reduces the MI consistently among subtypes and sizes including large MIs and ST-segment elevation MI

    Soluble TREM2 in CSF and its association with other biomarkers and cognition in autosomal-dominant Alzheimer's disease: a longitudinal observational study

    Get PDF
    BACKGROUND: Therapeutic modulation of TREM2-dependent microglial function might provide an additional strategy to slow the progression of Alzheimer's disease. Although studies in animal models suggest that TREM2 is protective against Alzheimer's pathology, its effect on tau pathology and its potential beneficial role in people with Alzheimer's disease is still unclear. Our aim was to study associations between the dynamics of soluble TREM2, as a biomarker of TREM2 signalling, and amyloid β (Aβ) deposition, tau-related pathology, neuroimaging markers, and cognitive decline, during the progression of autosomal dominant Alzheimer's disease. METHODS: We did a longitudinal analysis of data from the Dominantly Inherited Alzheimer Network (DIAN) observational study, which includes families with a history of autosomal dominant Alzheimer's disease. Participants aged over 18 years who were enrolled in DIAN between Jan 1, 2009, and July 31, 2019, were categorised as either carriers of pathogenic variants in PSEN1, PSEN2, and APP genes (n=155) or non-carriers (n=93). We measured amounts of cleaved soluble TREM2 using a novel immunoassay in CSF samples obtained every 2 years from participants who were asymptomatic (Clinical Dementia Rating [CDR]=0) and annually for those who were symptomatic (CDR>0). CSF concentrations of Aβ40, Aβ42, total tau (t-tau), and tau phosphorylated on threonine 181 (p-tau) were measured by validated immunoassays. Predefined neuroimaging measurements were total cortical uptake of Pittsburgh compound B PET (PiB-PET), cortical thickness in the precuneus ascertained by MRI, and hippocampal volume determined by MRI. Cognition was measured using a validated cognitive composite (including DIAN word list test, logical memory delayed recall, digit symbol coding test [total score], and minimental status examination). We based our statistical analysis on univariate and bivariate linear mixed effects models. FINDINGS: In carriers of pathogenic variants, a high amyloid burden at baseline, represented by low CSF Aβ42 (β=–4·28 × 10^{–2} [SE 0·013], p=0·0012), but not high cortical uptake in PiB-PET (β=–5·51 × 10^{–3} [0·011], p=0·63), was the only predictor of an augmented annual rate of subsequent increase in soluble TREM2. Augmented annual rates of increase in soluble TREM2 were associated with a diminished rate of decrease in amyloid deposition, as measured by Aβ42 in CSF (r=0·56 [0·22], p=0·011), in presymptomatic carriers of pathogenic variants, and with diminished annual rate of increase in PiB-PET (r=–0·67 [0·25], p=0·0060) in symptomatic carriers of pathogenic variants. Presymptomatic carriers of pathogenic variants with annual rates of increase in soluble TREM2 lower than the median showed a correlation between enhanced annual rates of increase in p-tau in CSF and augmented annual rates of increase in PiB-PET signal (r=0·45 [0·21], p=0·035), that was not observed in those with rates of increase in soluble TREM2 higher than the median. Furthermore, presymptomatic carriers of pathogenic variants with rates of increase in soluble TREM2 above or below the median had opposite associations between Aβ42 in CSF and PiB-PET uptake when assessed longitudinally. Augmented annual rates of increase in soluble TREM2 in presymptomatic carriers of pathogenic variants correlated with decreased cortical shrinkage in the precuneus (r=0·46 [0·22]), p=0·040) and diminished cognitive decline (r=0·67 [0·22], p=0·0020). INTERPRETATION: Our findings in autosomal dominant Alzheimer's disease position the TREM2 response within the amyloid cascade immediately after the first pathological changes in Aβ aggregation and further support the role of TREM2 on Aβ plaque deposition and compaction. Furthermore, these findings underpin a beneficial effect of TREM2 on Aβ deposition, Aβ-dependent tau pathology, cortical shrinkage, and cognitive decline. Soluble TREM2 could, therefore, be a key marker for clinical trial design and interpretation. Efforts to develop TREM2-boosting therapies are ongoing
    • …
    corecore