72 research outputs found

    Radioisotopic purity and imaging properties of cyclotron-produced 99mTc using direct 100Mo(p,2n) reaction

    Get PDF
    Evaluation of the radioisotopic purity of technetium-99m (99mTc) produced in GBq amounts by proton bombardment of enriched molibdenum-100 (100Mo) metallic targets at low proton energies (i.e. within 15\u201320 MeV) is conducted. This energy range was chosen since it is easily achievable by many conventional medical cyclotrons already available in the nuclear medicine departments of hospitals. The main motivation for such a study is in the framework of the research activities at the international level that have been conducted over the last few years to develop alternative production routes for the most widespread radioisotope used in medical imaging. The analysis of technetium isotopes and isomeric states (9xTc) present in the pertechnetate saline Na99mTcO4 solutions, obtained after the extraction/purification procedure, reveals radionuclidic purity levels basically in compliance with the limits recently issued by European Pharmacopoeia 9.3 (2018 Sodium pertechnetate (99mTc) injection 4801\u20133). Moreover, the impact of 9xTc contaminant nuclides on the final image quality is thoroughly evaluated, analyzing the emitted high-energy gamma rays and their influence on the image quality. The spatial resolution of images from cyclotron-produced 99mTc acquired with a mini-gamma camera was determined and compared with that obtained using technetium-99m solutions eluted from standard 99Mo/99mTc generators. The effect of the increased image background contribution due to Compton-scattered higher-energy gamma rays (E \u3b3 \u2009\u2009>\u2009\u2009200\u2009keV), which could cause image-contrast deterioration, was also studied. It is concluded that, due to the high radionuclidic purity of cyclotron-produced 99mTc using 100Mo(p,2n)99mTc reaction at a proton beam energy in the range 15.7\u201319.4 MeV, the resulting image properties are well comparable with those from the generator-eluted 99mTc

    Improving total body irradiation with a dedicated couch and 3D-printed patient-specific lung blocks: A feasibility study

    Get PDF
    Introduction: Total body irradiation (TBI) is an important component of the conditioning regimen in patients undergoing hematopoietic stem cell transplants. TBI is used in very few patients and therefore it is generally delivered with standard linear accelerators (LINACs) and not with dedicated devices. Severe pulmonary toxicity is the most common adverse effect after TBI, and patient-specific lead blocks are used to reduce mean lung dose. In this context, online treatment setup is crucial to achieve precise positioning of the lung blocks. Therefore, in this study we aim to report our experience at generating 3D-printed patient-specific lung blocks and coupling a dedicated couch (with an integrated onboard image device) with a modern LINAC for TBI treatment. Material and methods: TBI was planned and delivered (2Gy/fraction given twice a day, over 3 days) to 15 patients. Online images, to be compared with planned digitally reconstructed radiographies, were acquired with the couch-dedicated Electronic Portal Imaging Device (EPID) panel and imported in the iView software using a homemade Graphical User Interface (GUI). In vivo dosimetry, using Metal-Oxide Field-Effect Transistors (MOSFETs), was used to assess the setup reproducibility in both supine and prone positions. Results: 3D printing of lung blocks was feasible for all planned patients using a stereolithography 3D printer with a build volume of 14.5Ă—14.5Ă—17.5 cm3. The number of required pre-TBI EPID-images generally decreases after the first fraction. In patient-specific quality assurance, the difference between measured and calculated dose was generally<2%. The MOSFET measurements reproducibility along each treatment and patient was 2.7%, in average. Conclusion: The TBI technique was successfully implemented, demonstrating that our approach is feasible, flexible, and cost-effective. The use of 3D-printed patient-specific lung blocks have the potential to personalize TBI treatment and to refine the shape of the blocks before delivery, making them extremely versatile

    Cardiopoietic cell therapy for advanced ischemic heart failure: results at 39 weeks of the prospective, randomized, double blind, sham-controlled CHART-1 clinical trial

    Get PDF
    Cardiopoietic cells, produced through cardiogenic conditioning of patients' mesenchymal stem cells, have shown preliminary efficacy. The Congestive Heart Failure Cardiopoietic Regenerative Therapy (CHART-1) trial aimed to validate cardiopoiesis-based biotherapy in a larger heart failure cohort

    Some experimental studies on 89

    No full text

    Assessment of internal contamination hazard and fast monitoring forworkers involved in maintenance operations on pet cyclotrons

    No full text
    With the ever-increasing number of cyclotron installations, and therefore of the maintenance personnel involved, the possibility of swift, 'yes or no' screening for internal contamination becomes a prized asset. The present work presents one such procedure, evolved from an approximate whole body counting technique in widespread use in emergency situations. A detailed analysis of possible pathways for contamination leads to pinpointing the nuclides of interest. Different calibration methods are applied, showing moderate variation among them. The minimum detectable activity of order 1000 Bq is determined. The method proves sensitive enough to exclude significant contamination, or to identify its presence instantly 'on site' to prompt further in-depth investigation

    Legislative Documents

    Get PDF
    Also, variously referred to as: House bills; House documents; House legislative documents; legislative documents; General Court documents

    Assessment of internal contamination hazard and fast monitoring for workers involved in maintenance operations on PET cyclotrons

    No full text
    With the ever increasing number of cyclotron installations, and therefore of the maintenance personnel involved, the possibility of swift, “yes or no” screening for internal contamination becomes a prized asset. The present work presents one such procedure, evolved from an approximate whole body counting technique in widespread use in emergency situations. A detailed analysis of possible pathways for contamination leads to pinpointing the nuclides of interest. Different calibration methods are applied, showing moderate variation among them. An MDA of order 1000 Bq is determined. The method proves sensitive enough to exclude significant contamination, or identify its presence instantly “on site” to prompt further in depth investigation

    Synthesis of oncological [11C]radiopharmaceuticals for clinical PET.

    No full text
    Positron emission tomography (PET) is a nuclear medicine modality which provides quantitative images of biological processes in vivo at the molecular level. Several PET radiopharmaceuticals labeled with short-lived isotopes such as (18)F and (11)C were developed in order to trace specific cellular and molecular pathways with the aim of enhancing clinical applications. Among these [(11)C]radiopharmaceuticals are N-[(11)C]methyl-choline ([(11)C]choline), l-(S-methyl-[(11)C])methionine ([(11)C]methionine) and 1-[(11)C]acetate ([(11)C]acetate), which have gained an important role in oncology where the application of 2-[(18)F]fluoro-2-deoxy-d-glucose ([(18)F]FDG) is suboptimal. Nevertheless, the production of these radiopharmaceuticals did not reach the same level of standardization as for [(18)F]FDG synthesis. This review describes the most recent developments in the synthesis of the above-mentioned [(11)C]radiopharmaceuticals aiming to increase the availability and hence the use of [(11)C]choline, [(11)C]methionine and [(11)C]acetate in clinical practice
    • …
    corecore