842 research outputs found

    Randomized comparison of the effects of the vitamin D(3 )adequate intake versus 100 mcg (4000 IU) per day on biochemical responses and the wellbeing of patients

    Get PDF
    BACKGROUND: For adults, vitamin D intake of 100 mcg (4000 IU)/day is physiologic and safe. The adequate intake (AI) for older adults is 15 mcg (600 IU)/day, but there has been no report focusing on use of this dose. METHODS: We compared effects of these doses on biochemical responses and sense of wellbeing in a blinded, randomized trial. In Study 1, 64 outpatients (recruited if summer 2001 25(OH)D <61 nmol/L) were given 15 or 100 mcg/day vitamin D in December 2001. Biochemical responses were followed at subsequent visits that were part of clinical care; 37 patients completed a wellbeing questionnaire in December 2001 and February 2002. Subjects for Study 2 were recruited if their 25(OH)D was <51 nmol/L in summer 2001. 66 outpatients were given vitamin D; 51 completed a wellbeing questionnaire in both December 2002 and February 2003. RESULTS: In Study 1, basal summer 25-hydroxyvitamin D [25(OH)D] averaged 48 ± 9 (SD) nmol/L. Supplementation for more than 6 months produced mean 25(OH)D levels of 79 ± 30 nmol/L for the 15 mcg/day group, and 112 ± 41 nmol/L for the 100 mcg/day group. Both doses lowered plasma parathyroid hormone with no effect on plasma calcium. Between December and February, wellbeing score improved more for the 100-mcg/day group than for the lower-dosed group (1-tail Mann-Whitney p = 0.036). In Study 2, 25(OH)D averaged 39 ± 9 nmol/L, and winter wellbeing scores improved with both doses of vitamin D (two-tail p < 0.001). CONCLUSION: The highest AI for vitamin D brought summertime 25(OH)D to >40 nmol/L, lowered PTH, and its use was associated with improved wellbeing. The 100 mcg/day dose produced greater responses. Since it was ethically necessary to provide a meaningful dose of vitamin D to these insufficient patients, we cannot rule out a placebo wellbeing response, particularly for those on the lower dose. This work confirms the safety and efficacy of both 15 and 100 mcg/day vitamin D(3 )in patients who needed additional vitamin D

    The Offer of Advanced Imaging Techniques Leads to Higher Acceptance Rates for Screening Colonoscopy : a Prospective Study

    Get PDF
    BACKGROUND: Colonoscopy plays a fundamental role in early diagnosis and management of colorectal cancer and requires public and professional acceptance to ensure the ongoing success of screening programs. The aim of the study was to prospectively assess whether patient acceptance rates to undergo screening colonoscopy could be improved by the offer of advanced imaging techniques. MATERIALS AND METHODS: Overall, 372 randomly selected patients were prospectively included. A standardized questionnaire was developed that inquired of the patients their knowledge regarding advanced imaging techniques. Second, several media campaigns and information events were organized reporting about advanced imaging techniques, followed by repeated evaluation. After one year the evaluation ended. RESULTS: At baseline, 64% of the patients declared that they had no knowledge about new endoscopic methods. After twelve months the overall grade of information increased significantly from 14% at baseline to 34%. The percentage of patients who decided to undergo colonoscopy because of the offer of new imaging methods also increased significantly from 12% at baseline to 42% after 12 months. CONCLUSIONS: Patients were highly interested in the offer of advanced imaging techniques. Knowledge about these techniques could relatively easy be provided using local media campaigns. The offer of advanced imaging techniques leads to higher acceptance rates for screening colonoscopies

    High-definition endoscopy with digital chromoendoscopy for histologic prediction of distal colorectal polyps

    Get PDF
    Background: Distal diminutive colorectal polyps are common and accurate endoscopic prediction of hyperplastic or adenomatous polyp histology could reduce procedural time, costs and potential risks associated with the resection. Within this study we assessed whether digital chromoendoscopy can accurately predict the histology of distal diminutive colorectal polyps according to the ASGE PIVI statement. Methods: In this prospective cohort study, 224 consecutive patients undergoing screening or surveillance colonoscopy were included. Real time histology of 121 diminutive distal colorectal polyps was evaluated using high-definition endoscopy with digital chromoendoscopy and the accuracy of predicting histology with digital chromoendoscopy was assessed. Results: The overall accuracy of digital chromoendoscopy for prediction of adenomatous polyp histology was 90.1 %. Sensitivity, specificity, positive and negative predictive values were 93.3, 88.7, 88.7, and 93.2 %, respectively. In high-confidence predictions, the accuracy increased to 96.3 % while sensitivity, specificity, positive and negative predictive values were calculated as 98.1, 94.4, 94.5, and 98.1 %, respectively. Surveillance intervals with digital chromoendoscopy were correctly predicted with &gt;90 % accuracy. Conclusions: High-definition endoscopy in combination with digital chromoendoscopy allowed real-time in vivo prediction of distal colorectal polyp histology and is accurate enough to leave distal colorectal polyps in place without resection or to resect and discard them without pathologic assessment. This approach has the potential to reduce costs and risks associated with the redundant removal of diminutive colorectal polyps

    Dynamic nuclear polarization at high magnetic fields in liquids

    Get PDF
    High field dynamic nuclear polarization spectrometer for liquid samples have been constructed. ► The field dependence of the Overhauser DNP efficiency has been measured for the first time up to 9.2 T. ► High DNP enhancements for liquid samples have been observed at high magnetic fields. ► The enhancements have been compared with results from NMRD, MD and theoretical models. ► Coherent and relaxation effects within fast magnetic field changes have been analyzed

    The vitamin D grey areas in pediatric primary care. Very low serum 25-hydroxyvitamin D levels in asymptomatic children living in northeastern Italy

    Get PDF
    The principal questions about the vitamin D topic are far to be resolved: in which children 25-hydroxyvitamin D blood testing is appropriate and how much cholecalciferol should be given in the absence of the test? Analyzing vitamin D status in a group of children cared by a "family pediatrician" in northeastern Italy we noted a high incidence of deficiency in asymptomatic preschool children without risk factors. As routine vitamin D testing is not recommended in the average risk population the supplementation with cholecalciferol represents a "grey area" mostly in pediatric primary care

    The impact of vitamin D status on changes in bone mineral density during treatment with bisphosphonates and after discontinuation following long-term use in post-menopausal osteoporosis

    Get PDF
    BACKGROUND: It is still unclear whether addition of calcium/vitamin D supplements leads to an incremental benefit in patients taking bisphosphonates and whether achievement of serum level of 25 (OH) vitamin D of at least 70 nmol/L has an impact on the skeletal response to bisphosphonates. Moreover the maintenance of BMD after bisphosphonates withdrawal with the continuation of calcium/vitamin D supplements only, remains uncertain. The aims were to assess the impact of vitamin D status on changes in bone mineral density (BMD) in firstly patients with post-menopausal osteoporosis on bisphosphonates and secondly following discontinuation of bisphosphonates after long-term use. METHODS: Two patient groups were recruited. The first study population comprised of 112 women treated with a bisphosphonate. The second study population consisted of 35 women who had been on bisphosphonates for > 5 years in whom the treatment agent was discontinued. Baseline BMD, changes in BMD following treatment, duration of treatment, serum 25 (OH) vitamin D, parathyroid hormone (PTH), urine C-terminal telopeptides of type 1 collagen (CTX) were obtained on the study participants. RESULTS: In the first study group, subjects with serum vitamin D concentrations (> 70 nmol/L) had a significantly lower serum PTH level (mean [SEM] 41 [2] ng/L). PTH concentrations of 41 ng/L or less was associated with a significantly higher increase in BMD at the hip following treatment with bisphosphonates compared to patients with PTH > 41 ng/L (2.5% [0.9] v/s -0.2% [0.9], P = 0.04). In the second study group, discontinuation of bisphosphonate for 15 months after long-term treatment did not result in significant bone loss at the lumbar spine and total hip, although a trend towards gradual decline in BMD at the femoral neck was observed. CONCLUSION: the data suggest that optimal serum 25 (OH) vitamin D concentration may lead to further reduction in bone loss at the hip in patients on bisphosphonates. A prospective controlled trial is needed to evaluate whether the response to bisphosphonates is influenced by vitamin D status. BMD is preserved at the lumbar spine and total hip following discontinuation of bisphosphonate for a short period following long-term treatment, although a gradual loss occurs at the femoral neck

    Platte TFI Program -Innovative Solutions to Hydrostatic Testing

    Get PDF
    ABSTRACT Platte Pipe Line experienced an operational failure in July 1997. This failure was attributable to operational pressure cycle fatigue crack growth of a hook-crack in the longitudinal seam weld. This defect had grown to failure over a 24-year time period since it had been hydrostatically tested in 1973. In response to this failure, the Department of Transportation (DOT) Office of Pipeline Safety (OPS) issued a corrective order to verify the integrity of this pipeline through either hydrostatic testing or an approved in-line inspection program. An emerging technology, a Transverse Field Inspection (TFI) tool, was identified as a possible solution to this problem. Even though this inspection tool had not been used previously to identify seam-weld defects, this technology certainly showed promise. The results of our program show that the TFI program resulted in less impact on the operations of this pipeline and provided greater assurance than hydrostatic testing for the longterm operational reliability of this pipeline system. This paper describes the steps required to use this inspection tool for the Platte Pipe Line rehabilitation program
    corecore