1,305 research outputs found

    Elimination of Double Peaks in the Iodimetric Flow Injection Visible Spectrophotometric Determination of Sulphite Using a Single-Channel Manifold

    Get PDF
    A flow injection method of determining sulphite with amperometric monitoring of iodine using a single-channel manifold in which iodine is formed in the reverse flow injection (rFI) manner and reacts with sulphite dispersing in the normal flow injection (nFI) manner has been adapted for use with visible spectrophotometry. The carrier stream consists of an alkaline solution containing iodate and an excess of iodide: injections of acid and then of acidified sulphite are made. The decrease in the iodine signal (measured at 352 nm) in the presence of sulphite is proportional to the sulphite concentration in the injectate. The alkalinity of the carrier stream was adjusted to reduce the signal widths and to prevent the appearance of double peaks. A rectilinear decrease in signal size (down to ca. 10% of the signal size in the absence of sulphite) was obtained in the range 1 x 10-s_7 x 10-4 M sulphite using a single-channel manifold consisting of 3 m of 0.8 mm bore transmission tubing with a flow-rate of 5 ml min-1 and an injection volume of 15 rd, when the carrier stream was 6.7 x 1 Q-6 Min iodate, 6.7 x 10-2 Min iodide and 3.5 x 1 Q-3 Min sodium hydroxide, and the sample solution was 0.1 M in hydrochloric acid

    Shapes of Flow Injection Signals: Effect of Refractive Index on Spectrophotometric Signals Obtained for On-Line Formation of Bromine from Bromate, Bromide, and Hydrogen Ion in a Single-Channel Manifold Using Large-Volume Time-Based Injections

    Get PDF
    The shapes of the spectrophotometric signals obtained with a single-channel manifold for large-volume (4 ml) time-based injections for the six possible combinations of the reagents bromate, bromide and nitric acid in the injectate and carrier stream, by which bromine can be formed on-line, have been determined. The injectate and carrier stream were 5.25 x 10-4 M in bromate, 0.030 M in bromide and 1 M in nitric acid when these reagents were present. The signals consisted of two separate peaks caused by formation of bromine at the front and rear boundaries of the injected bolus. When both injectate and carrier stream were 1 M in nitric acid (i.e., for the reagent combination H+Br03- - H+Br-)the two peaks were of equal height, and the signal was. virtually the same whichever solution was used as the injectate. In reagent combinations where only one solution contained nitric acid the peaks were different in size, the smaller peak being that produced by the boundary in which the acidic solution was flowing behind the other solution. This difference in size between the front and rear peaks was shown to be caused by refractive index effects. When the refractive indices of the two solutions were matched either by increasing the potassium bromide concentration or by making the non-acidic solution 7% in sodium nitrate, the peaks became equal in size. When the potassium bromide concentration was increased there was an appreciable increase in peak size (about 4-fold): the changes in the amount of bromine formed must be due to kinetic or equilibrium effects. This increase in size did not occur when sodium nitrate was used to balance the refractive indices

    Heterocyst placement strategies to maximize growth of cyanobacterial filaments

    Full text link
    Under conditions of limited fixed-nitrogen, some filamentous cyanobacteria develop a regular pattern of heterocyst cells that fix nitrogen for the remaining vegetative cells. We examine three different heterocyst placement strategies by quantitatively modelling filament growth while varying both external fixed-nitrogen and leakage from the filament. We find that there is an optimum heterocyst frequency which maximizes the growth rate of the filament; the optimum frequency decreases as the external fixed-nitrogen concentration increases but increases as the leakage increases. In the presence of leakage, filaments implementing a local heterocyst placement strategy grow significantly faster than filaments implementing random heterocyst placement strategies. With no extracellular fixed-nitrogen, consistent with recent experimental studies of Anabaena sp. PCC 7120, the modelled heterocyst spacing distribution using our local heterocyst placement strategy is qualitatively similar to experimentally observed patterns. As external fixed-nitrogen is increased, the spacing distribution for our local placement strategy retains the same shape while the average spacing between heterocysts continuously increases.Comment: This is an author-created, un-copyedited version of an article accepted for publication in Physical Biology. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher-authenticated version will be available onlin

    Elemental abundances and minimum mass of heavy elements in the envelope of HD 189733b

    Full text link
    Oxygen (O) and carbon (C) have been inferred recently to be subsolar in abundance from spectra of the atmosphere of the transiting hot Jupiter HD 189733b. Yet, the mass and radius of the planet coupled with structure models indicate a strongly supersolar abundance of heavy elements in the interior of this object. Here we explore the discrepancy between the large amount of heavy elements suspected in the planet's interior and the paucity of volatiles measured in its atmosphere. We describe the formation sequence of the icy planetesimals formed beyond the snow line of the protoplanetary disk and calculate the composition of ices ultimately accreted in the envelope of HD 189733b on its migration pathway. This allows us to reproduce the observed volatile abundances by adjusting the mass of ices vaporized in the envelope. The predicted elemental mixing ratios should be 0.15--0.3 times solar in the envelope of HD 189733b if they are fitted to the recent O and C determinations. However, our fit to the minimum mass of heavy elements predicted by internal structure models gives elemental abundances that are 1.2--2.4 times oversolar in the envelope of HD189733b. We propose that the most likely cause of this discrepancy is irradiation from the central star leading to development of a radiative zone in the planet's outer envelope which would induce gravitational settling of elements. Hence, all strongly irradiated extrasolar planets should present subsolar abundances of volatiles. We finally predict that the abundances of nitrogen (N), sulfur (S) and phosphorus (P) are of ∌\sim 2.8×10−52.8 \times 10^{-5}, 5.3×10−65.3 \times 10^{-6} and 1.8×10−71.8 \times 10^{-7} relative to H2_2, respectively in the atmosphere of HD 189733b.Comment: Accepted for publication in Astronomy & Astrophysic

    A fundamental conflict of care: nurses' accounts of balancing sleep with taking vital signs observations at night.

    Get PDF
    AIMS AND OBJECTIVES: To explore why adherence to vital signs observations scheduled by an Early Warning Score protocol reduces at night. BACKGROUND: Regular vital signs observations can reduce avoidable deterioration in hospital. Early Warning Score protocols set the frequency of these observations by the severity of a patient's condition. Vital signs observations are taken less frequently at night, even with an Early Warning Score in place, but no literature has explored why. DESIGN: A qualitative interpretative design informed this study. METHODS: Seventeen semi-structured interviews with nursing staff working on wards with varying levels of adherence to scheduled vital signs observations. A thematic analysis approach was used. RESULTS: At night, nursing teams found it difficult to balance the competing care goals of supporting sleep with taking vital signs observations. The night-time frequency of these observations was determined by clinical judgement, ward-level expectations of observation timing and the risk of disturbing other patients. Patients with COPD or dementia could be under-monitored while patients nearing the end of life could be over-monitored. CONCLUSION: In this study we found an Early Warning Score algorithm focused on deterioration prevention did not account for long-term management or palliative care trajectories. Nurses were therefore less inclined to wake such patients to take vital signs observations at night. However the perception of widespread exceptions and lack of evidence regarding optimum frequency risks delegitimising the Early Warning Score approach. This may pose a risk to patient safety, particularly patients with dementia or chronic conditions. RELEVANCE TO CLINICAL PRACTICE: Nurses should document exceptions and discuss these with the wider team. Hospitals should monitor why vital signs observations are missed at night, identify which groups are under-monitored and provide guidance on prioritising competing expectations. Early Warning Score protocols should take account of different care trajectories. This article is protected by copyright. All rights reserved

    Geometric representation of interval exchange maps over algebraic number fields

    Full text link
    We consider the restriction of interval exchange transformations to algebraic number fields, which leads to maps on lattices. We characterize renormalizability arithmetically, and study its relationships with a geometrical quantity that we call the drift vector. We exhibit some examples of renormalizable interval exchange maps with zero and non-zero drift vector, and carry out some investigations of their properties. In particular, we look for evidence of the finite decomposition property: each lattice is the union of finitely many orbits.Comment: 34 pages, 8 postscript figure
    • 

    corecore