124 research outputs found

    Economic Optimization of a Concentrating Solar Power Plant with Molten-salt Thermocline Storage

    Get PDF
    System-level simulation of a molten-salt thermocline tank is undertaken in response to year-long historical weather data and corresponding plant control. Such a simulation is enabled by combining a finite-volume model of the tank that includes a sufficiently faithful representation at low computation cost with a system-level power tower plant model. Annual plant performance of a 100 MWe molten-salt power tower plant is optimized as a function of the thermocline tank size and the plant solar multiple (SM). The effectiveness of the thermocline tank in storing and supplying hot molten salt to the power plant is found to exceed 99% over a year of operation, independent of tank size. The electrical output of the plant is characterized by its capacity factor (CF) over the year, which increases with solar multiple and thermocline tank size albeit with diminishing returns. The economic performance of the plant is characterized with a levelized cost of electricity (LCOE) metric. A previous study conducted by the authors applied a simplified cost metric for plant performance. The current study applies a more comprehensive financial approach and observes a minimum cost of 12.2 ¢/kWhe with a solar multiple of 3 and a thermocline tank storage capacity of 16 h. While the thermocline tank concept is viable and economically feasible, additional plant improvements beyond those pertaining to storage are necessary to achieve grid parity with fossil fuels

    Latent-Heat Augmentation of Thermocline Energy Storage for Concentrating Solar Power – A System-Level Assessment

    Get PDF
    Molten-salt thermocline tanks are a low-cost energy storage option for concentrating solar power plants. Despite the potential economic advantage, the capacity of thermocline tanks to store sufficient amounts of high-temperature heat is limited by the low energy density of the constituent sensible-heat storage media. A promising design modification replaces conventional rock filler inside the tank with an encapsulated phase-change material (PCM), contributing a latent heat storage mechanism to increase the overall energy density. The current study presents a new finite-volume approach to simulate mass and energy transport inside a latent heat thermocline tank at low computational cost. This storage model is then integrated into a system-level model of a molten-salt power tower plant to inform tank operation with respect to realistic solar collection and power production. With this system model, PCMs with different melting temperatures and heats of fusion are evaluated for their viability in latent heat storage for solar plants. Thermocline tanks filled with a single PCM do not yield a substantial increase in annual storage or plant output over a conventional rock-filled tank of equal size. As the melting temperature and heat of fusion are increased, the ability of the PCM to support steam generation improves but the corresponding ability of the thermocline tank to utilize this available latent heat decreases. This trend results from an inherent deconstruction of the heat-exchange region inside the tank between sensible and latent heat transfer, preventing effective use of the added phase change for daily plant operations. This problem can be circumvented with a cascaded filler structure composed of multiple PCMs with their melting temperatures tuned along the tank height. However, storage benefits with these cascaded tank structures are shown to be highly sensitive to the proper selection of the PCM melting points relative to the thermocline tank operating temperatures

    Thermomechanical Simulation of the Solar One Thermocline Storage Tank

    Get PDF
    The growing interest in large-scale solar power production has led to a renewed exploration of thermal storage technologies. In a thermocline storage system, heat transfer fluid (HTF) from the collection field is simultaneously stored at both excited and dead thermal states inside a single tank by exploiting buoyancy forces. A granulated porous medium included in the tank provides additional thermal mass for storage and reduces the volume of HTF required. While the thermocline tank offers a low-cost storage option, thermal ratcheting of the tank wall (generated by reorientation of the granular material from continuous thermal cycling) poses a significant design concern. A comprehensive simulation of the 170 MWht thermocline tank used in conjunction with the Solar One pilot plant is performed with a multidimensional two-temperature computational fluid dynamics model to investigate ratcheting potential. In operation from 1982 to 1986, this tank was subject to extensive instrumentation, including multiple strain gages along the tank wall to monitor hoop stress. Temperature profiles along the wall material are extracted from the simulation results to compute hoop stress via finite element models and compared with the original gage data. While the strain gages experienced large uncertainty, the maximum predicted hoop stress agrees to within 6.8% of the maximum stress recorded by the most reliable strain gages

    Comparative Analysis of Single- and Dual-media Thermocline Tanks for Thermal Energy Storage in Concentrating Solar Power Plants

    Get PDF
    A molten-salt thermocline tank is a low-cost option for thermal energy storage (TES) in concentrating solar power (CSP) plants. Typical dual-media thermocline (DMT) tanks contain molten salt and a filler material that provides sensible heat capacity at reduced cost. However, conventional quartzite rock filler introduces the potential for thermomechanical failure by successive thermal ratcheting of the tank wall under cyclical operation. To avoid this potential mode of failure, the tank may be operated as a singlemedium thermocline (SMT) tank containing solely molten salt. However, in the absence of filler material to dampen tank-scale convection eddies, internal mixing can reduce the quality of the stored thermal energy. To assess the relative merits of these two approaches, the operation of DMT and SMT tanks is simulated under different periodic charge/discharge cycles and tank wall boundary conditions to compare the performance with and without a filler material. For all conditions assessed, both thermocline tank designs have excellent thermal storage performance, although marginally higher firstand second-law efficiencies are predicted for the SMT tank. While heat loss through the tank wall to the ambient induces internal flow nonuniformities in the SMT design over the scale of the entire tank, strong stratification maintains separation of the hot and cold regions by a narrow thermocline; thermocline growth is limited by the low thermal diffusivity of the molten salt. Heat transport and flow phenomena inside the DMT tank, on the other hand, are governed to a great extent by thermal diffusion, which causes elongation of the thermocline. Both tanks are highly resistant to performance loss over periods of static operation, and the deleterious effects of dwell time are limited in both tank designs

    Models for Metal Hydride Particle Shape, Packing, and Heat Transfer

    Full text link
    A multiphysics modeling approach for heat conduction in metal hydride powders is presented, including particle shape distribution, size distribution, granular packing structure, and effective thermal conductivity. A statistical geometric model is presented that replicates features of particle size and shape distributions observed experimentally that result from cyclic hydride decreptitation. The quasi-static dense packing of a sample set of these particles is simulated via energy-based structural optimization methods. These particles jam (i.e., solidify) at a density (solid volume fraction) of 0.665+/-0.015 - higher than prior experimental estimates. Effective thermal conductivity of the jammed system is simulated and found to follow the behavior predicted by granular effective medium theory. Finally, a theory is presented that links the properties of bi-porous cohesive powders to the present systems based on recent experimental observations of jammed packings of fine powder. This theory produces quantitative experimental agreement with metal hydride powders of various compositions.Comment: 12 pages, 12 figures, 2 table

    The geographical distribution and burden of trachoma in Africa.

    Get PDF
    BACKGROUND: There remains a lack of epidemiological data on the geographical distribution of trachoma to support global mapping and scale up of interventions for the elimination of trachoma. The Global Atlas of Trachoma (GAT) was launched in 2011 to address these needs and provide standardised, updated and accessible maps. This paper uses data included in the GAT to describe the geographical distribution and burden of trachoma in Africa. METHODS: Data assembly used structured searches of published and unpublished literature to identify cross-sectional epidemiological data on the burden of trachoma since 1980. Survey data were abstracted into a standardised database and mapped using geographical information systems (GIS) software. The characteristics of all surveys were summarized by country according to data source, time period, and survey methodology. Estimates of the current population at risk were calculated for each country and stratified by endemicity class. RESULTS: At the time of writing, 1342 records are included in the database representing surveys conducted between 1985 and 2012. These data were provided by direct contact with national control programmes and academic researchers (67%), peer-reviewed publications (17%) and unpublished reports or theses (16%). Prevalence data on active trachoma are available in 29 of the 33 countries in Africa classified as endemic for trachoma, and 1095 (20.6%) districts have representative data collected through population-based prevalence surveys. The highest prevalence of active trachoma and trichiasis remains in the Sahel area of West Africa and Savannah areas of East and Central Africa and an estimated 129.4 million people live in areas of Africa confirmed to be trachoma endemic. CONCLUSION: The Global Atlas of Trachoma provides the most contemporary and comprehensive summary of the burden of trachoma within Africa. The GAT highlights where future mapping is required and provides an important planning tool for scale-up and surveillance of trachoma control

    Prevalence of Trachomatous Trichiasis in Ten Evaluation Units of Embu and Kitui Counties, Kenya.

    Get PDF
    BACKGROUND: Late-stage blinding sequalae of trachoma such as trachomatous trichiasis (TT) typically take decades to develop and often do so in the absence of ongoing ocular Chlamydia trachomatis infection. This suggests that most TT risk accumulates in early life; as a result, population-level TT incidence and prevalence can remain high years after C. trachomatis transmission among children has decreased. In Embu and Kitui counties, Kenya, the prevalence of trachomatous inflammation - follicular is low in children. In this survey, we set out to determine the prevalence of TT in ten evaluation units (EUs) in these counties. METHODS: We undertook ten cross-sectional prevalence surveys for TT. In each EU, people aged ≥15 years were selected by a two-stage cluster sampling method and examined for TT. Those with TT were asked questions on whether they had been offered management for it. Prevalence was adjusted to the underlying age and gender structure of the population. RESULTS: A total of 18,987 people aged ≥15 years were examined. Per EU, the median number of examined participants was 1,656 (range: 1,451 - 3,016) and median response rate was 86% (range: 81 - 95%). The prevalence of TT unknown to the health system in people aged ≥15 years was above the threshold for elimination (≥0.2%) in all ten EUs studied (range: 0.2-0.7%). TT was significantly more common in older than younger individuals and in women than in men. DISCUSSION: Provision of surgical services should be strengthened in Embu and Kitui counties of Kenya to achieve the World Health Organization threshold for eliminating TT as a public health problem

    MyD88 TIR domain higher-order assembly interactions revealed by microcrystal electron diffraction and serial femtosecond crystallography.

    Get PDF
    MyD88 and MAL are Toll-like receptor (TLR) adaptors that signal to induce pro-inflammatory cytokine production. We previously observed that the TIR domain of MAL (MALTIR) forms filaments in vitro and induces formation of crystalline higher-order assemblies of the MyD88 TIR domain (MyD88TIR). These crystals are too small for conventional X-ray crystallography, but are ideally suited to structure determination by microcrystal electron diffraction (MicroED) and serial femtosecond crystallography (SFX). Here, we present MicroED and SFX structures of the MyD88TIR assembly, which reveal a two-stranded higher-order assembly arrangement of TIR domains analogous to that seen previously for MALTIR. We demonstrate via mutagenesis that the MyD88TIR assembly interfaces are critical for TLR4 signaling in vivo, and we show that MAL promotes unidirectional assembly of MyD88TIR. Collectively, our studies provide structural and mechanistic insight into TLR signal transduction and allow a direct comparison of the MicroED and SFX techniques
    • …
    corecore