8 research outputs found

    A Qualitative Exploration of the Use of Contraband Cell Phones in Secured Facilities

    Get PDF
    Offenders accepting contraband cell phones in secured facilities violate state corrections law, and the possession of these cell phones is a form of risk taking behavior. When offenders continue this risky behavior, it affects their decision making in other domains where they are challenging authorities; and may impact the length of their incarceration. This qualitative phenomenological study examined the lived experience of ex-offenders who had contraband cell phones in secured correctional facilities in order to better understand their reasons for taking risks with contraband cell phones. The theoretical foundation for this study was Trimpop\u27s risk-homeostasis and risk-motivation theories that suggest an individual\u27s behaviors adapt to negotiate between perceived risk and desired risk in order to achieve satisfaction. The research question explored beliefs and perceptions of ex-offenders who chose to accept the risk of using contraband cell phones during their time in secured facilities. Data were collected anonymously through recorded telephone interviews with 8 male adult ex-offenders and analyzed using thematic content analysis. Findings indicated participants felt empowered by possession of cell phones in prison, and it was an acceptable risk to stay connected to family out of concern for loved ones. The study contributes to social change by providing those justice system administrators, and prison managers responsible for prison cell phone policies with more detailed information about the motivations and perspectives of offenders in respect to using contraband cell phones while imprisoned in secured facilities

    Radiation dose among different cardiac and vascular invasive procedures: The RODEO study

    No full text
    Interventional radiology and cardiology procedures contribute significantly to the collective dose of radiation exposure from medical interventions. Recent and dedicated studies comparing directly these procedures in term of patient radiation exposure are lacking. Our aim was to compare radiation exposure among different interventional procedures performed under fluoroscopic guidance. The RODEO study (NCT: 02972736) is an international observational retrospective multicenter study enrolling all patients undergoing diagnostic or interventional procedures performed by different interventional operators (i.e. radiologists, interventional cardiologists or electrophysiologists) in 6 centers, without exclusion criteria. The primary end-point of the study was the comparison of dose area product (DAP) among interventional cardiology, electrophysiology or interventional radiology procedures. A total of 17,711 procedures were included in the study: 13,522 interventional cardiology, 2352 electrophysiology and 1864 interventional radiology procedures. The highest DAP values were observed for interventional radiology procedures (74Gy∗cm2 [Interquartile range 27–178Gy∗cm2]), followed by interventional cardiology (40Gy∗cm2 [22–78Gy∗cm2]) and electrophysiology procedures (13Gy∗cm2 [4–44Gy∗cm2], p<0.0001). In term of specific procedures, the highest DAP values were observed in structural or valvular cardiac procedures (134Gy∗cm2 [51–260Gy∗cm2]) whereas the lowest DAP values in pacemaker insertion (11Gy∗cm2 [4–28Gy∗cm2]). In this large multicenter study, the highest radiation exposure was observed in procedures performed by interventional radiologists. However, among specific procedures, structural or valvular cardiac procedures were associated with the highest radiation exposure

    Acute Kidney Injury After Radial or Femoral Access for Invasive Acute Coronary Syndrome Management: AKI-MATRIX.

    No full text
    BACKGROUND It remains unclear whether radial access (RA), compared with femoral access (FA), mitigates the risk of acute kidney injury (AKI). OBJECTIVES The authors assessed the incidence of AKI in patients with acute coronary syndrome (ACS) enrolled in the MATRIX-Access (Minimizing Adverse Haemorrhagic Events by Transradial Access Site and Systemic Implementation of Angiox) trial. METHODS Among 8,404 patients, 194 (2.3%) were excluded due to missing creatinine values, no or an incomplete coronary angiogram, or previous dialysis. The primary AKI-MATRIX endpoint was AKI, defined as an absolute (>0.5 mg/dl) or a relative (>25%) increase in serum creatinine (sCr). RESULTS AKI occurred in 634 patients (15.4%) with RA and 712 patients (17.4%) with FA (odds ratio [OR]: 0.87; 95% confidence interval [CI]: 0.77 to 0.98; p = 0.0181). A >25% sCr increase was noted in 633 patients (15.4%) with RA and 710 patients (17.3%) with FA (OR: 0.87; 95% CI: 0.77 to 0.98; p = 0.0195), whereas a >0.5 mg/dl absolute sCr increase occurred in 175 patients (4.3%) with RA versus 223 patients (5.4%) with FA (OR: 0.77; 95% CI: 0.63 to 0.95; p = 0.0131). By implementing the Kidney Disease Improving Global Outcomes criteria, AKI was 3-fold less prevalent and trended lower with RA (OR: 0.85; 95% CI: 0.70 to 1.03; p = 0.090), with stage 3 AKI occurring in 28 patients (0.68%) with RA versus 46 patients (1.12%) with FA (p = 0.0367). Post-intervention dialysis was needed in 6 patients (0.15%) with RA and 14 patients (0.34%) with FA (p = 0.0814). Stratified analyses suggested greater benefit with RA than FA in patients at greater risk for AKI. CONCLUSIONS In ACS patients who underwent invasive management, RA was associated with a reduced risk of AKI compared with FA. (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX [MATRIX]; NCT01433627)

    Table1_A more-Comers populAtion trEated with an ultrathin struts polimer-free Sirolimus stent: an Italian post-maRketing study (the CAESAR registry).docx

    No full text
    IntroductionThe use of contemporary drug-eluting stents (DES) has significantly improved outcomes of patients with coronary artery disease (CAD) undergoing percutaneous coronary intervention (PCI). However, concerns exist regarding the long-term proinflammatory effects of durable polymer coatings used in most DES, potentially leading to long-term adverse events. First-generation polymer-free stent technologies, such as sirolimus- and probucol-eluting stents (PF-SES), have shown an excellent safety and efficacy profile. The aim of this study was to evaluate the safety and efficacy of the new ultrathin Coroflex ISAR NEO PF-SES, in a more-comers PCI population.MethodsThe CAESAR (a more-Comers populAtion trEated with an ultrathin struts polimer-free Sirolimus stent: An Italian post-maRketing study) registry is a multicenter, prospective study conducted in Italy, enrolling more-comers CAD patients undergoing PCI with the Coroflex ISAR NEO stent. Patients with left main (LM) disease, cardiogenic shock (CS), or severely reduced left-ventricular ejection fraction (LVEF) were excluded. The primary endpoint was target-lesion revascularization (TLR) at 1 year.ResultsA total of 425 patients were enrolled at 13 centers (mean age 66.9 ± 11.6 years, Diabetes mellitus 29%, acute coronary syndrome 67%, chronic total occlusion 9%). Of these, 40.9% had multivessel disease (MVD) and in 3.3% cases, the target lesion was in-stent restenosis (ISR). Clinical device success was reached in 422 (99.6%) cases. At 1 year, only two (0.5%) subjects presented ischemia-driven TLR. The 1-year rates of target vessel revascularization and MACE were 0.5% and 5.1%, respectively. Major bleeding was observed in four (1.0%) patients.ConclusionIn this multicenter, prospective registry, the use of a new ultrathin Coroflex ISAR NEO PF-SES in a more-comers PCI population showed good safety and efficacy at 1 year.</p

    Design and rationale for the minimizing adverse haemorrhagic events by transradial access site and systemic implementation of angioX program

    No full text

    Acute Kidney Injury After Radial or Femoral Access for Invasive Acute Coronary Syndrome Management: AKI-MATRIX

    No full text

    [Updated SICI-GISE position paper on institutional and operator requirements for transcatheter aortic valve implantation]

    No full text
    Transcatheter aortic valve implantation (TAVI) has revolutionized the management of patients with symptomatic severe aortic stenosis and has become the standard of care for inoperable patients and the preferred therapy for those at increased surgical risk with peculiar clinical and anatomic features. Technology advances, growing experience and accumulating data prompted the update of the 2011 Italian Society of Interventional Cardiology (SICI-GISE) position paper on institutional and operator requirements to perform TAVI. The main objective of this document is to provide a guidance to assess the potential of institutions and operators to initiate and maintain an efficient TAVI program
    corecore