    Short-Cut Under Pressure Stenting the Tortuous Neonatal Duct Involves Induced Spasm

    Get PDF

    Avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively.

    Full text link
    peer reviewed[en] OBJECTIVES: The aim of this study was to evaluate the impact of changing the sizing strategy in aortic valve replacement using the Perceval sutureless prosthesis on haemodynamic outcomes and postoperative pacemaker implantation. METHODS: Retrospective analysis of patients implanted with the Perceval valve between 2007 and 2019 was performed by comparing patients implanted before the modification of sizing strategy (OLD group) and after (NEW group). The outcome parameters evaluated were the implanted prosthesis size, haemodynamical profile and postoperative pacemaker implantation. RESULTS: The entire patient cohort (784 patients) consisted of 52% female patients, with a mean age of 78.53 [standard deviation (SD): 5.8] years and a mean EuroSCORE II of 6.3 (range 0.7-76). In 55.5% of cases, surgery was combined. The NEW cohort had more male patients (54.6% vs 43.4%) (P = 0.002). Mean implanted valve size, corrected for body surface area, was significantly lower in the NEW cohort (13.1, SD: 1.4 vs 13.5, SD: 1.4 mm/m2, P < 0.001). The 30-day mortality was 3.4%. Peak and mean transvalvular gradients at discharge were significantly lower in the NEW versus OLD groups: 24.4 mmHg (SD: 9.2) versus 28.4 mmHg (SD: 10.3) (P < 0.001) and 13.6 mmHg (SD: 5.3) versus 15.5 mmHg (SD: 6.0) (P < 0.001). The mean effective opening area and the indexed effective opening area, respectively, increased from 1.5 cm2 (SD: 0.5) and 0.85 cm2/m2 (SD: 0.27) in the OLD group to 1.7 cm2 (SD: 0.5) and 0.93 cm2/m2 (SD: 0.30) in the NEW group (P < 0.001). No difference was found in paravalvular leakage ≥1/4. Centrovalvular leakage ≥1/4 significantly decreased from 18% to 7.9% (P < 0.001). With the new sizing, the new postoperative pacemaker implantation rate decreased significantly from 11% to 6.1% (P = 0.016). CONCLUSIONS: Correct sizing of sutureless aortic valves is crucial to obtain the best possible haemodynamics and avoid complications

    Sheep can be used as animal model of regional myocardial remodeling and controllable work

    Get PDF
    Background: Pacing the right heart has been shown to induce reversible conduction delay and subse­quent asymmetric remodeling of the left ventricle (LV) in dogs and pigs. Both species have disadvantages in animal experiments. Therefore the aim of this study was to develop a more feasible and easy-to-use animal model in sheep. Methods: Dual-chamber (DDD) pacemakers with epicardial leads on the right atrium and right ven­tricular free wall were implanted in 13 sheep. All animals underwent 8 weeks of chronic rapid pacing at 180 bpm. Reported observations were made at 110 bpm. Results: DDD pacing acutely induced a left bundle branch block (LBBB) — like pattern with almost doubling in QRS width and the appearance of a septal flash, indicating mechanical dyssynchrony. Atrial pacing (AAI) resulted in normal ventricular conduction and function. During 8 weeks of rapid DDD pacing, animals developed LV remodeling (confirmed with histology) with septal wall thinning (–30%, p &lt; 0.05), lateral wall thickening (+22%, p &lt; 0.05), LV volume increase (+32%, p &lt; 0.05), decrease of LV ejection fraction (–31%, p &lt; 0.05), and functional mitral regurgitation. After 8 weeks, segmental pressure-strain-loops, representing regional myocardial work, were recorded. Switching from AAI to DDD pacing decreased immediately work in the septum and increased it in the lateral wall (–69 and +41%, respectively, p &lt; 0.05). Global LV stroke work and dP/dtmax decreased (–27% and -25%, respectively, p &lt; 0.05). Conclusions: This study presents the development a new sheep model with an asymmetrically remod­eled LV. Simple pacemaker programing allows direct modulation of regional myocardial function and work. This animal model provides a new and valuable alternative for canine or porcine models and has the potential to become instrumental for investigating regional function and loading conditions on regional LV remodeling

    Oxygenated machine perfusion at room temperature as an alternative for static cold storage in porcine donor hearts

    Get PDF
    Background There is a continued interest in ex situ heart perfusion as an alternative strategy for donor heart preservation. We hypothesize that oxygenated machine perfusion of donor hearts at a temperature that avoids both normothermia and deep hypothermia offers adequate and safe preservation. Methods Cardioplegia-arrested porcine donor hearts were randomly assigned to six hours of preservation using cold storage (CS, n = 5) or machine perfusion using an oxygenated acellular perfusate at 21 degrees C (MP, n = 5). Subsequently, all grafts were evaluated using the Langendorff method for 120 min. Metabolic parameters and histology were analyzed. Systolic function was assessed by contractility and elastance. Diastolic function was assessed by lusitropy and stiffness. Results For both groups, in vivo baseline and post-Langendorff biopsies were comparable, as were lactate difference and myocardial oxygen consumption. Injury markers gradually increased and were comparable. Significant weight gain was seen in MP (p = 0.008). Diastolic function was not impaired in MP, and lusitropy was superior from 30 min up to 90 min of reperfusion. Contractility was superior in MP during the first hour of evaluation. Conclusion We conclude that the initial functional outcome of MP-preserved hearts was transiently superior compared to CS, with no histological injury post-Langendorff. Our machine perfusion strategy could offer feasible and safe storage of hearts prior to transplantation. Future studies are warranted for further optimization

    Oxygenated machine perfusion at room temperature as an alternative for static cold storage in porcine donor hearts

    Get PDF
    Background There is a continued interest in ex situ heart perfusion as an alternative strategy for donor heart preservation. We hypothesize that oxygenated machine perfusion of donor hearts at a temperature that avoids both normothermia and deep hypothermia offers adequate and safe preservation. Methods Cardioplegia-arrested porcine donor hearts were randomly assigned to six hours of preservation using cold storage (CS, n = 5) or machine perfusion using an oxygenated acellular perfusate at 21 degrees C (MP, n = 5). Subsequently, all grafts were evaluated using the Langendorff method for 120 min. Metabolic parameters and histology were analyzed. Systolic function was assessed by contractility and elastance. Diastolic function was assessed by lusitropy and stiffness. Results For both groups, in vivo baseline and post-Langendorff biopsies were comparable, as were lactate difference and myocardial oxygen consumption. Injury markers gradually increased and were comparable. Significant weight gain was seen in MP (p = 0.008). Diastolic function was not impaired in MP, and lusitropy was superior from 30 min up to 90 min of reperfusion. Contractility was superior in MP during the first hour of evaluation. Conclusion We conclude that the initial functional outcome of MP-preserved hearts was transiently superior compared to CS, with no histological injury post-Langendorff. Our machine perfusion strategy could offer feasible and safe storage of hearts prior to transplantation. Future studies are warranted for further optimization.</p

    Personalised external aortic root support (PEARS) in Marfan syndrome: Analysis of 1-9 year outcomes by intention-to-treat in a cohort of the first 30 consecutive patients to receive a novel tissue and valve-conserving procedure, compared with the published results of aortic root replacement

    Get PDF
    Objective: Among people with Marfan syndrome who have a typical aortic root aneurysm, dissection is a characteristic cause of premature death. To pre-empt Type A dissection, composite root replacement with a mechanical valve became the standard of care in the 1980s and 1990s. This is being superseded by valvesparing aortic root replacement to avoid lifelong anticoagulation. In 2004, a total root and valve-sparing procedure, personalised external aortic support, was introduced. We report here results among the first 30 recipients. Methods: From cross-sectional digital images, the patient's own aorta is modelled by computer aided design and a replica is made in thermoplastic by rapid prototyping. On this, a personalised support of a macroporous polymer mesh is manufactured. The mesh is positioned around the aorta, closely applied from the aortoventricular junction to beyond the brachiocephalic artery. The operation is performed with a beating heart and usually without cardiopulmonary bypass. Results: Between 2004 and 2011, 30 patients, median age 28 years (IQR 20-44) had this operation and have been prospectively followed for 1.4-8.8 years by February 2013. During a total of 133 patient-years there were no deaths or cerebrovascular, aortic or valve-related events. These early outcomes are better than published results for the more radical extirpative root replacement operations. Conclusions: The aortic valve, the root architecture, and the blood/endothelia interface are conserved. The perioperative burden is less and there has been freedom from aortic and valvular events. A prospective comparative study is planned

    Paediatric aortic valve replacement:a meta-analysis and microsimulation study

    Get PDF
    AIMS: To support decision-making in children undergoing aortic valve replacement (AVR), by providing a comprehensive overview of published outcomes after paediatric AVR, and microsimulation-based age-specific estimates of outcome with different valve substitutes. METHODS AND RESULTS: A systematic review of published literature reporting clinical outcome after paediatric AVR (mean age &lt;18 years) published between 1/1/1990 and 11/08/2021 was conducted. Publications reporting outcome after paediatric Ross procedure, mechanical AVR (mAVR), homograft AVR (hAVR), and/or bioprosthetic AVR were considered for inclusion. Early risks (&lt;30d), late event rates (&gt;30d) and time-to-event data were pooled and entered into a microsimulation model. Sixty-eight studies, of which one prospective and 67 retrospective cohort studies, were included, encompassing a total of 5259 patients (37 435 patient-years; median follow-up: 5.9 years; range 1-21 years). Pooled mean age for the Ross procedure, mAVR, and hAVR was 9.2 ± 5.6, 13.0 ± 3.4, and 8.4 ± 5.4 years, respectively. Pooled early mortality for the Ross procedure, mAVR, and hAVR was 3.7% (95% CI, 3.0%-4.7%), 7.0% (5.1%-9.6%), and 10.6% (6.6%-17.0%), respectively, and late mortality rate was 0.5%/year (0.4%-0.7%/year), 1.0%/year (0.6%-1.5%/year), and 1.4%/year (0.8%-2.5%/year), respectively. Microsimulation-based mean life-expectancy in the first 20 years was 18.9 years (18.6-19.1 years) after Ross (relative life-expectancy: 94.8%) and 17.0 years (16.5-17.6 years) after mAVR (relative life-expectancy: 86.3%). Microsimulation-based 20-year risk of aortic valve reintervention was 42.0% (95% CI: 39.6%-44.6%) after Ross and 17.8% (95% CI: 17.0%-19.4%) after mAVR. CONCLUSION: Results of paediatric AVR are currently suboptimal with substantial mortality especially in the very young with considerable reintervention hazards for all valve substitutes, but the Ross procedure provides a survival benefit over mAVR. Pros and cons of substitutes should be carefully weighed during paediatric valve selection.</p

    Matched comparison of decellularized homografts and bovine jugular vein conduits for pulmonary valve replacement in congenital heart disease

    Get PDF
    For decades, bovine jugular vein conduits (BJV) and classic cryopreserved homografts have been the two most widely used options for pulmonary valve replacement (PVR) in congenital heart disease. More recently, decellularized pulmonary homografts (DPH) have provided an alternative avenue for PVR. Matched comparison of patients who received DPH for PVR with patients who received bovine jugular vein conduits (BJV) considering patient age group, type of heart defect, and previous procedures. 319 DPH patients were matched to 319 BJV patients; the mean age of BJV patients was 15.3 (SD 9.5) years versus 19.1 (12.4) years in DPH patients (p = 0.001). The mean conduit diameter was 24.5 (3.5) mm for DPH and 20.3 (2.5) mm for BJV (p < 0.001). There was no difference in survival rates between the two groups after 10 years (97.0 vs. 98.1%, p = 0.45). The rate of freedom from endocarditis was significantly lower for BJV patients (87.1 vs. 96.5%, p = 0.006). Freedom from explantation was significantly lower for BJV at 10 years (81.7 vs. 95.5%, p = 0.001) as well as freedom from any significant degeneration at 10 years (39.6 vs. 65.4%, p < 0.001). 140 Patients, matched for age, heart defect type, prior procedures, and conduit sizes of 20–22 mm (± 2 mm), were compared separately; mean age BJV 8.7 (4.9) and DPH 9.5 (7.3) years (p = n.s.). DPH showed 20% higher freedom from explantation and degeneration in this subgroup (p = 0.232). Decellularized pulmonary homografts exhibit superior 10-year results to bovine jugular vein conduits in PVR

    The role of transesophageal echocardiography in guiding heart donation after circulatory death.

    Full text link
    peer reviewedHeart donation after circulatory death (DCD) can significantly expand the heart donor pool, helping to overcome the problem of organ shortage and the increase in waiting list mortality and morbidity. To improve the outcome of DCD heart transplantation, thoraco-abdominal normothermic regional perfusion (TA-NRP) can be performed by selectively restoring circulation followed by in vivo functional heart assessment. Here, we report on the use of periprocedural transoesophageal echocardiography (TOE) as a minimally invasive cardiac assessment tool during different stages of a DCD heart procurement procedure using TA-NRP. We conclude that TOE is a valuable method to assess the donor heart for transplantation eligibility before and after withdrawal of life-sustaining therapy and during subsequent TA-NRP

    Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries

    Get PDF
    Abstract Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries