    Two-dimensional two-component plasma with adsorbing impurities

    Full text link
    We study the behavior of the two-dimensional two-component plasma in the presence of some adsorbing impurities. Using a solvable model, we find analytic expressions for the thermodynamic properties of the plasma such as the nn-body densities, the grand potential, and the pressure. We specialize in the case where there are one or two adsorbing point impurities in the plasma, and in the case where there are one or two parallel adsorbing lines. In the former case we study the effective interaction between the impurities, due to the charge redistribution around them. The latter case is a model for electrodes with adsorbing sticky sites on their surface

    Statistical Multifragmentation in Central Au+Au Collisions at 35 MeV/u

    Full text link
    Multifragment disintegrations, measured for central Au + Au collisions at E/A = 35 MeV, are analyzed with the Statistical Multifragmentation Model. Charge distributions, mean fragment energies, and two-fragment correlation functions are well reproduced by the statistical breakup of a large, diluted and thermalized system slightly above the multifragmentation threshold.Comment: Latex file, 8 pages + 4 postscript figures available upon request from [email protected]

    Multifragment production in Au+Au at 35 MeV/u

    Full text link
    Multifragment disintegration has been measured with a high efficiency detection system for the reaction Au+AuAu + Au at E/A=35 MeVE/A = 35\ MeV. From the event shape analysis and the comparison with the predictions of a many-body trajectories calculation the data, for central collisions, are compatible with a fast emission from a unique fragment source.Comment: 9 pages, LaTex file, 4 postscript figures available upon request from [email protected]. - to appear in Phys. Lett.

    The Activity of the Spanish Teratology Information Services (SITTE and SITE) during 2008

    Get PDF
    Otros Resultados: Actividad TraslacionalWe summarize the activity of the two Teratology Information Services: SITTE (for health professionals) and SITE (for the general population), during 2008. The total number of calls received in both services was 4,910 (943 from SITTE and 3,967 from SITE). This number has increased compared to previous year. The main users of the SITTE (gynecologists 54.96%) and the SITE (pregnant women 79.89%), have asked preponderantly about the use of drugs (70.22% of the SITTE and 37.49% of the SITE phone calls), during ongoing pregnancies at the moment they were calling (82.82% in the SITTE and 85.18% in the SITE). Additionally, we analyze the type of consulted factors and some characteristics of the users to orientate our work more effectively to the actual demand.N

    Fast Photon Detection for Particle Identification with COMPASS RICH-1

    Get PDF
    Particle identification at high rates is an important challenge for many current and future high-energy physics experiments. The upgrade of the COMPASS RICH-1 detector requires a new technique for Cherenkov photon detection at count rates of several 10610^6 per channel in the central detector region, and a read-out system allowing for trigger rates of up to 100 kHz. To cope with these requirements, the photon detectors in the central region have been replaced with the detection system described in this paper. In the peripheral regions, the existing multi-wire proportional chambers with CsI photocathode are now read out via a new system employing APV pre-amplifiers and flash ADC chips. The new detection system consists of multi-anode photomultiplier tubes (MAPMT) and fast read-out electronics based on the MAD4 discriminator and the F1-TDC chip. The RICH-1 is in operation in its upgraded version for the 2006 CERN SPS run. We present the photon detection design, constructive aspects and the first Cherenkov light in the detector.Comment: Proceedings of the Imaging 2006 conference, Stockholm, Sweden, 27-30 June 2006, 5 pages, 6 figures, to appear in NIM A; corrected typo in caption of Fig.

    Fast photon detection for the COMPASS RICH detector

    Get PDF
    The COMPASS experiment at the SPS accelerator at CERN uses a large scale Ring Imaging CHerenkov detector (RICH) to identify pions, kaons and protons in a wide momentum range. For the data taking in 2006, the COMPASS RICH has been upgraded in the central photon detection area (25% of the surface) with a new technology to detect Cherenkov photons at very high count rates of several 10^6 per second and channel and a new dead-time free read-out system, which allows trigger rates up to 100 kHz. The Cherenkov photons are detected by an array of 576 visible and ultra-violet sensitive multi-anode photomultipliers with 16 channels each. The upgraded detector showed an excellent performance during the 2006 data taking.Comment: Proceeding of the IPRD06 conference (Siena, Okt. 06

    The Fast Read-out System for the MAPMTs of COMPASS RICH-1

    Full text link
    A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the RICH is based on the high-sensitivity MAD4 preamplifier-discriminator and the dead-time free F1-TDC chip characterized by high-resolution. The readout electronics has been designed taking into account the high photon flux in the central part of the detector and the requirement to run at high trigger rates of up to 100 kHz with negligible dead-time. The system is designed as a very compact setup and is mounted directly behind the multi-anode photomultipliers. The data are digitized on the frontend boards and transferred via optical links to the readout system. The read-out electronics system is described in detail together with its measured performances.Comment: Proceeding of RICH2007 Conference, Trieste, Oct. 2007. v2: minor change

    Spin asymmetry A_1^d and the spin-dependent structure function g_1^d of the deuteron at low values of x and Q^2

    Get PDF
    We present a precise measurement of the deuteron longitudinal spin asymmetry A_1^d and of the deuteron spin-dependent structure function g_1^d at Q^2 < 1 GeV^2 and 4*10^-5 < x < 2.5*10^-2 based on the data collected by the COMPASS experiment at CERN during the years 2002 and 2003. The statistical precision is tenfold better than that of the previous measurement in this region. The measured A_1^d and g_1^d are found to be consistent with zero in the whole range of x.Comment: 17 pages, 10 figure

    Gluon polarization in the nucleon from quasi-real photoproduction of high-pT hadron pairs

    Get PDF
    We present a determination of the gluon polarization Delta G/G in the nucleon, based on the helicity asymmetry of quasi-real photoproduction events, Q^2<1(GeV/c)^2, with a pair of large transverse-momentum hadrons in the final state. The data were obtained by the COMPASS experiment at CERN using a 160 GeV polarized muon beam scattered on a polarized 6-LiD target. The helicity asymmetry for the selected events is = 0.002 +- 0.019(stat.) +- 0.003(syst.). From this value, we obtain in a leading-order QCD analysis Delta G/G=0.024 +- 0.089(stat.) +- 0.057(syst.) at x_g = 0.095 and mu^2 =~ 3 (GeV}/c)^2.Comment: 10 pages, 3 figure

    The Deuteron Spin-dependent Structure Function g1d and its First Moment

    Get PDF
    We present a measurement of the deuteron spin-dependent structure function g1d based on the data collected by the COMPASS experiment at CERN during the years 2002-2004. The data provide an accurate evaluation for Gamma_1^d, the first moment of g1d(x), and for the matrix element of the singlet axial current, a0. The results of QCD fits in the next to leading order (NLO) on all g1 deep inelastic scattering data are also presented. They provide two solutions with the gluon spin distribution function Delta G positive or negative, which describe the data equally well. In both cases, at Q^2 = 3 (GeV/c)^2 the first moment of Delta G is found to be of the order of 0.2 - 0.3 in absolute value.Comment: fits redone using MRST2004 instead of MRSV1998 for G(x), correlation matrix adde
    • …
    corecore