2,248 research outputs found
Detailed investigation of a vaporising fuel spray. Part 1: Experimental investigation of time averaged spray
A laser tomographic light scattering technique provides rapid and accurate high resolution measurements of droplet sizes, concentrations, and vaporization. Measurements using a computer interfaced thermocouple are presented and it is found that the potential exists for separating gas and liquid temperature measurements and diagnosing local spray density by in situ analysis of the response characteristics of the thermocouple. The thermocouple technique provides a convenient means for measuring mean gas velocity in both hot and cold two phase flows. The experimental spray is axisymmetric and has carefully controlled initial and boundary conditions. The flow is designed to give relatively insignificant transfer of momentum and mass from spray to air flow. The effects of (1) size-dependent droplet dispersion by the turbulence, (2) the initial spatial segregation of droplet sizes during atomization, and (3) the interaction between droplets and coherent large eddies are diagnosed
Developement of real time diagnostics and feedback algorithms for JET in view of the next step
Real time control of many plasma parameters will be an essential aspect in
the development of reliable high performance operation of Next Step Tokamaks.
The main prerequisites for any feedback scheme are the precise real-time
determination of the quantities to be controlled, requiring top quality and
highly reliable diagnostics, and the availability of robust control algorithms.
A new set of real time diagnostics was recently implemented on JET to prove the
feasibility of determining, with high accuracy and time resolution, the most
important plasma quantities. With regard to feedback algorithms, new
model–based controllers were developed to allow a more robust control of
several plasma parameters. Both diagnostics and algorithms were successfully
used in several experiments, ranging from H-mode plasmas to configuration with
ITBs. Since elaboration of computationally heavy measurements is often
required, significant attention was devoted to non-algorithmic methods like
Digital or Cellular Neural/Nonlinear Networks. The real time hardware and
software adopted architectures are also described with particular attention to
their relevance to ITER.Comment: 12th International Congress on Plasma Physics, 25-29 October 2004,
Nice (France
Children\u27s Understanding of the Concept of Physical Activity
This study evaluated 4th-grade students\u27 understanding of the concept of physical activity and assessed the effects of two interventions to enhance the students\u27 understanding of this concept. Students were randomly assigned to 1 of 3 conditions: the video group (n=40) watched a 5-min video describing physical activity; the verbal group (n=42) listened to a generic description of physical activity; the control group received no instruction (n=45). Students completed a 17-item checklist testing their understanding of the concept of physical activity. Compared to controls, students in the verbal and video group demonstrated significantly higher checklist scores, with the video group scoring significantly higher than the verbal group. Only 35.6% of the controls compared to 52.4% and 70.0% of the verbal and video group respectively, could classify \u3e 15 of the checklist items correctly. The results indicate that, without intervention, children have a limited understanding of the concept of physical activity
Recommended from our members
Determinants of boat velocity during a 200 m race in elite Paralympic sprint kayakers
This study investigates the relationships between boat velocity, stroke rate and displacement per stroke in Paracanoe 200m Sprint Kayak races. Data were analysed from 646, 200m efforts performed by 13 international Paracanoe athletes between 2017 and 2020 (Male: N= 6, female: N= 7) using boat-based GPS unit (Catapult S5). Significant differences between the Paralympic classifications were observed for boat velocity, stroke rate and displacement per stroke across both genders (p < 0.001) and Paracanoe classification (p < 0.001). Stroke rate was found to be the best predictor of boat velocity across classifications explaining between 13% and 34% of the variation. However, displacement per stroke was found to be more important for males than females potentially due to strength and anthropometric differences. Boat velocity, stroke rate and displacement per stroke values for the final 150m (measured in 50 m splits) indicated evidence for a mix of all-out and positive pacing strategies. The results of this study suggest intricate differences exist in Paracanoe Sprint Kayak based on gender and classification between athletes. This information is useful in the coaching of Paracanoe Sprint Kayak with evidence that physical preparation, training, and race strategy can be individualised to each athlete
Individualization of piperacillin dosing for critically ill patients: Dosing software to optimize antimicrobial therapy
Piperacillin-tazobactam is frequently used for empirical and targeted therapy of infections in critically ill patients. Considerable pharmacokinetic (PK) variability is observed in critically ill patients. By estimating an individual's PK, dosage optimization Bayesian estimation techniques can be used to calculate the appropriate piperacillin regimen to achieve desired drug exposure targets. The aim of this study was to establish a population PK model for piperacillin in critically ill patients and then analyze the performance of the model in the dose optimization software program BestDose. Linear, with estimated creatinine clearance and weight as covariates, Michaelis-Menten (MM) and parallel linear/MM structural models were fitted to the data from 146 critically ill patients with nosocomial infection. Piperacillin concentrations measured in the first dosing interval, from each of 8 additional individuals, combined with the population model were embedded into the dose optimization software. The impact of the number of observations was assessed. Precision was assessed by (i) the predicted piperacillin dosage and by (ii) linear regression of the observed-versus-predicted piperacillin concentrations from the second 24 h of treatment. We found that a linear clearance model with creatinine clearance and weight as covariates for drug clearance and volume of distribution, respectively, best described the observed data. When there were at least two observed piperacillin concentrations, the dose optimization software predicted a mean piperacillin dosage of 4.02 g in the 8 patients administered piperacillin doses of 4.00 g. Linear regression of the observed-versus-predicted piperacillin concentrations for 8 individuals after 24 h of piperacillin dosing demonstrated an r2 of > 0.89. In conclusion, for most critically ill patients, individualized piperacillin regimens delivering a target serum piperacillin concentration is achievable. Further validation of the dosage optimization software in a clinical trial is required. Copyrigh
Brain Computer Interfaces for inclusion
All in-text references underlined in blue are linked to publications on ResearchGate, letting you access and read them immediately
Tracking of Physical Activity, Physical Inactivity, and Health-Related Physical Fitness in Rural Youth
This study examined the tracking of selected measures of physical activity, inactivity, and fitness in a cohort of rural youth. Students (N=181, 54.7% female, 63.5% African American) completed test batteries during their fifth- (age=10.7±0.7 years), sixth-, and seventh-grade years. The Previous Day Physical Activity Recall (PDPAR) was used to assess 30-min blocks of vigorous physical activity (VPA), moderate-to-vigorous physical activity (MVPA), TV watching and other sedentary activities, and estimated energy expenditure (EE). Fitness measures included the PWC 170 cycle ergometer test, strength tests, triceps skinfold thickness, and BMI. Intraclass correlation coefficients (ICCs) for VPA, MVPA, and after-school EE ranged from 0.63 to 0.78. ICCs ranged from 0.49 to 0.71 for measures of inactivity and from 0.78 to 0.82 for the fitness measures. These results indicate that measures of physical activity, inactivity, and physical fitness tend to track during the transition from elementary to middle school
Minority and mode conversion heating in (3He)-H JET plasma
Radio frequency (RF) heating experiments have recently been conducted in JET (He-3)-H plasmas. This type of plasmas will be used in ITER's non-activated operation phase. Whereas a companion paper in this same PPCF issue will discuss the RF heating scenario's at half the nominal magnetic field, this paper documents the heating performance in (He-3)-H plasmas at full field, with fundamental cyclotron heating of He-3 as the only possible ion heating scheme in view of the foreseen ITER antenna frequency bandwidth. Dominant electron heating with global heating efficiencies between 30% and 70% depending on the He-3 concentration were observed and mode conversion (MC) heating proved to be as efficient as He-3 minority heating. The unwanted presence of both He-4 and D in the discharges gave rise to 2 MC layers rather than a single one. This together with the fact that the location of the high-field side fast wave (FW) cutoff is a sensitive function of the parallel wave number and that one of the locations of the wave confluences critically depends on the He-3 concentration made the interpretation of the results, although more complex, very interesting: three regimes could be distinguished as a function of X[He-3]: (i) a regime at low concentration (X[He-3] < 1.8%) at which ion cyclotron resonance frequency (ICRF) heating is efficient, (ii) a regime at intermediate concentrations (1.8 < X[He-3] < 5%) in which the RF performance is degrading and ultimately becoming very poor, and finally (iii) a good heating regime at He-3 concentrations beyond 6%. In this latter regime, the heating efficiency did not critically depend on the actual concentration while at lower concentrations (X[He-3] < 4%) a bigger excursion in heating efficiency is observed and the estimates differ somewhat from shot to shot, also depending on whether local or global signals are chosen for the analysis. The different dynamics at the various concentrations can be traced back to the presence of 2 MC layers and their associated FW cutoffs residing inside the plasma at low He-3 concentration. One of these layers is approaching and crossing the low-field side plasma edge when 1.8 < X[He-3] < 5%. Adopting a minimization procedure to correlate the MC positions with the plasma composition reveals that the different behaviors observed are due to contamination of the plasma. Wave modeling not only supports this interpretation but also shows that moderate concentrations of D-like species significantly alter the overall wave behavior in He-3-H plasmas. Whereas numerical modeling yields quantitative information on the heating efficiency, analytical work gives a good description of the dominant underlying wave interaction physics
Adjustment to colostomy: stoma acceptance, stoma care self-efficacy and interpersonal relationships
‘The definitive version is available at www.blackwell-synergy.com.’ Copyright Blackwell Publishing. DOI: 10.1111/j.1365-2648.2007.04446.xThis paper is a report of a study to examine adjustment and its relationship with stoma acceptance and social interaction, and the link between stoma care self-efficacy and adjustment in the presence of acceptance and social interactions.Peer reviewe
- …