171 research outputs found

    Trapping radioactive ^{82}Rb in an optical dipole trap and evidence of spontaneous spin polarization

    Full text link
    Optical trapping of selected species of radioactive atoms has great potential in precision measurements for testing fundamental physics such as EDM, PNC and parity violating beta-decay asymmetry correlation coefficients. We report trapping of 10^4 radioactive ^{82}Rb atoms (t_{1/2}=75 s) with a trap lifetime of ~55 seconds in an optical dipole trap. Transfer efficiency from the magneto-optical trap was ~14%. We further report the evidence of spontaneous spin polarization of the atoms in optical dipole trap loading. This advancement is an important step towards a new generation of precision J-beta correlations measurements with polarized ^{82}Rb atoms.Comment: 4 pages, 4 figure

    "500 Jahre Eroberung und Widerstand Lateinamerikas"

    Get PDF

    Can Foreign Policy Make a Difference to Health?

    Get PDF
    As part of the PLoS Medicine series on Global Health Diplomacy, Sigrun Møgedal and Benedikte Alveberg provide a diplomatic perspective on how foreign policy can make a difference to global health challenges

    Global health and foreign policy.

    Get PDF
    Health has long been intertwined with the foreign policies of states. In recent years, however, global health issues have risen to the highest levels of international politics and have become accepted as legitimate issues in foreign policy. This elevated political priority is in many ways a welcome development for proponents of global health, and it has resulted in increased funding for and attention to select global health issues. However, there has been less examination of the tensions that characterize the relationship between global health and foreign policy and of the potential effects of linking global health efforts with the foreign-policy interests of states. In this paper, the authors review the relationship between global health and foreign policy by examining the roles of health across 4 major components of foreign policy: aid, trade, diplomacy, and national security. For each of these aspects of foreign policy, the authors review current and historical issues and discuss how foreign-policy interests have aided or impeded global health efforts. The increasing relevance of global health to foreign policy holds both opportunities and dangers for global efforts to improve health

    Small optic suspensions for Advanced LIGO input optics and other precision optical experiments

    Get PDF
    We report on the design and performance of small optic suspensions developed to suppress seismic motion of out-of-cavity optics in the Input Optics subsystem of the Advanced LIGO interferometric gravitational wave detector. These compact single stage suspensions provide isolation in all six degrees of freedom of the optic, local sensing and actuation in three of them, and passive damping for the other three

    Characterization of thermal effects in the Enhanced LIGO Input Optics

    Get PDF
    We present the design and performance of the LIGO Input Optics subsystem as implemented for the sixth science run of the LIGO interferometers. The Initial LIGO Input Optics experienced thermal side effects when operating with 7 W input power. We designed, built, and implemented improved versions of the Input Optics for Enhanced LIGO, an incremental upgrade to the Initial LIGO interferometers, designed to run with 30 W input power. At four times the power of Initial LIGO, the Enhanced LIGO Input Optics demonstrated improved performance including better optical isolation, less thermal drift, minimal thermal lensing and higher optical efficiency. The success of the Input Optics design fosters confidence for its ability to perform well in Advanced LIGO

    Sufficient conditions for bang-bang control in Hilbert space

    Full text link
    Sufficient conditions for bang-bang and singular optimal control are established in the case of linear operator equations with cost functionals which are the sum of linear and quadratic terms, that is, Ax = u , J ( u )=( r,x )+β( x,x ), β>0. For example, if A is a bounded operator with a bounded inverse from a Hilbert space H into itself and the control set U is the unit ball in H , then an optimal control is bang-bang (has norm l) if 0⩽β1/2∥ A −1 * r ∥·∥ A ∥ 2 .Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/45225/1/10957_2004_Article_BF00928120.pd

    Health Diplomacy the Adaptation of Global Health Interventions to Local Needs in sub-Saharan Africa and Thailand: Evaluating Findings from Project Accept (HPTN 043).

    Get PDF
    Study-based global health interventions, especially those that are conducted on an international or multi-site basis, frequently require site-specific adaptations in order to (1) respond to socio-cultural differences in risk determinants, (2) to make interventions more relevant to target population needs, and (3) in recognition of 'global health diplomacy' issues. We report on the adaptations development, approval and implementation process from the Project Accept voluntary counseling and testing, community mobilization and post-test support services intervention. We reviewed all relevant documentation collected during the study intervention period (e.g. monthly progress reports; bi-annual steering committee presentations) and conducted a series of semi-structured interviews with project directors and between 12 and 23 field staff at each study site in South Africa, Zimbabwe, Thailand and Tanzania during 2009. Respondents were asked to describe (1) the adaptations development and approval process and (2) the most successful site-specific adaptations from the perspective of facilitating intervention implementation. Across sites, proposed adaptations were identified by field staff and submitted to project directors for review on a formally planned basis. The cross-site intervention sub-committee then ensured fidelity to the study protocol before approval. Successfully-implemented adaptations included: intervention delivery adaptations (e.g. development of tailored counseling messages for immigrant labour groups in South Africa) political, environmental and infrastructural adaptations (e.g. use of local community centers as VCT venues in Zimbabwe); religious adaptations (e.g. dividing clients by gender in Muslim areas of Tanzania); economic adaptations (e.g. co-provision of income generating skills classes in Zimbabwe); epidemiological adaptations (e.g. provision of 'youth-friendly' services in South Africa, Zimbabwe and Tanzania), and social adaptations (e.g. modification of terminology to local dialects in Thailand: and adjustment of service delivery schedules to suit seasonal and daily work schedules across sites). Adaptation selection, development and approval during multi-site global health research studies should be a planned process that maintains fidelity to the study protocol. The successful implementation of appropriate site-specific adaptations may have important implications for intervention implementation, from both a service uptake and a global health diplomacy perspective

    The Advanced LIGO Input Optics

    Get PDF
    The advanced LIGO gravitational wave detectors are nearing their design sensitivity and should begin taking meaningful astrophysical data in the fall of 2015. These resonant optical interferometers will have unprecedented sensitivity to the strains caused by passing gravitational waves. The input optics play a significant part in allowing these devices to reach such sensitivities. Residing between the pre-stabilized laser and the main interferometer, the input optics subsystem is tasked with preparing the laser beam for interferometry at the sub-attometer level while operating at continuous wave input power levels ranging from 100 mW to 150 W. These extreme operating conditions required every major component to be custom designed. These designs draw heavily on the experience and understanding gained during the operation of Initial LIGO and Enhanced LIGO. In this article, we report on how the components of the input optics were designed to meet their stringent requirements and present measurements showing how well they have lived up to their design

    The advanced LIGO input optics

    Get PDF
    The advanced LIGO gravitational wave detectors are nearing their design sensitivity and should begin taking meaningful astrophysical data in the fall of 2015. These resonant optical interferometers will have unprecedented sensitivity to the strains caused by passing gravitational waves. The input optics play a significant part in allowing these devices to reach such sensitivities. Residing between the pre-stabilized laser and the main interferometer, the input optics subsystem is tasked with preparing the laser beam for interferometry at the sub-attometer level while operating at continuous wave input power levels ranging from 100 mW to 150 W. These extreme operating conditions required every major component to be custom designed. These designs draw heavily on the experience and understanding gained during the operation of Initial LIGO and Enhanced LIGO. In this article, we report on how the components of the input optics were designed to meet their stringent requirements and present measurements showing how well they have lived up to their design
    corecore