151 research outputs found

    Wild-isolated Neurospora crassa strains that increase fertility of crosses with segmental aneuploids used to establish that a large duplication suppresses RIP in a smaller duplication

    Get PDF
    Crosses involving strains bearing large segmental duplications are characteristically barren and produce only very few viable ascospores. We report here that the productivity of duplication x euploid crosses can be influenced by the euploid parent. The yield of ascospores was exceptionally low in crosses with the wild-isolated strains Golikro (FGSC# 4830) and Costa Rica (FGSC# 852) and exceptionally high in crosses with Lahore-1 (FGSC #1824), Dagguluru-1 (FGSC #3360), Okeechobee (FGSC # 3968), and Tiassale (FGSC # 4825). The four strains that increased productivity were used in crosses with strains bearing the duplication Dp(IBj5) together with a small (1.3 kb) duplication of the erg-3 gene. This made it possible to obtain sufficient numbers of progeny to establish that presence of Dp(IBj5) suppresses RIP in erg-3

    A multicenter randomized controlled clinical pilot study of buccally micro‐veneered lithium‐disilicate and zirconia crowns supported by titanium base abutments: 1‐year outcomes

    Full text link
    Objectives: To investigate survival rates, technical and biologic outcomes of buccally micro-veneered all-ceramic single implant crowns. Material and methods: Sixty subjects randomly received immediately or early placed implants. Crowns out of lithium-disilicate (n = 30) and zirconia-ceramic (n = 30) were bonded to titanium-base-abutments. Restorations were inspected at baseline (BL) and during follow-up visits (6, 12 months). Technical and biologic parameters were recorded. Data were analysed descriptively. Differences between groups were tested with Student's t-test. Paired T-test was used when comparing data from the same implant or tooth over time. Linear model repeated measures were used to test differences between materials over time. Differences in counts were evaluated using Pearson Chi-square test. The level of significance was at p < .05. Results: After a mean observation time of 13.2 ± 2.4 months, 54 restorations were re-examined. The implant survival rate was 98.3%, and the restoration survival rate was 100%. One early implant failure occurred. Two minor chippings occurred in lithium-disilicate restorations. No chippings or fractures occurred in any zirconia restorations at 1 year (0%). The technical complication rate was 3.7%, with 7.7% complications among the lithium-disilicate restorations and no differences between the two materials (p = .558). At 1-year follow-up, mean Bleeding on Probing (BOP) was higher at implants (0.27 ± 0.3) than adjacent teeth (0.17 ± 0.18) (p = .046) with no differences between materials (p = .36). Differences in pocket probing depth (PPD) between implants and adjacent teeth were significant (p < .01). Jemt Index improved significantly from BL to 1-y-follow-up (p < .001). Conclusions: Preliminary results were good, suggesting that the ceramic type does not impact technical and biologic parameters. Keywords: all-ceramic single crowns; chipping; clinical trials; implant-borne reconstructions; technical outcome

    Effect of splinting scan bodies on the trueness of complete-arch digital implant scans with 5 different intraoral scanners

    Get PDF
    Statement of problem: The absence of fixed reference points can affect the trueness of complete-arch intraoral digital implant scans. The effect of splinting intraoral scan bodies (ISBs) or the inclusion of artificial landmarks (AL) on the trueness of complete-arch digital implant scans is still unclear. Purpose: The purpose of this study was to analyze the effect of splinting ISBs or the inclusion of AL on the trueness of complete-arch digital implant scans with 5 intraoral scanners (IOSs). Material and methods: Six tissue-level dental implants (Straumann Tissue Level) were placed in an edentulous patient, and the correspondent definitive cast was digitized with a desktop scanner (IScan4D LS3i) to obtain the reference digital cast. Digital scans (n=10) were performed with 5 IOSs: TRIOS 4, Virtuo Vivo, Medit i700, iTero Element 5D, and Cerec Primescan. Three different scanning techniques were evaluated: conventional (cIOSs), splinted (sIOSs), and AL (AL-IOSs). The scan data obtained were imported into a metrology software program and superimposed to the reference digital cast by using a best-fit algorithm. The overall deviations of the positions of the ISBs were evaluated by using the root-mean-square (RMS) error (α=.05). Results: The mean ±standard deviation trueness values for the cIOSs, sIOSs, and AL-IOSs groups were 48 ±8 ”m, 53 ±7 ”m, and 49 ±11 ”m, respectively, with no statistically significant differences (P=.06). Significant differences were found for the IOSs used with each technique (P<.001). Primescan (27 ±4 ”m cIOSs; 28 ±3 ”m sIOSs; 31 ±3 ”m AL-IOSs) showed significantly higher trueness than iTero 5D (47 ±5 ”m cIOSs; 47 ±4 ”m sIOSs; 50 ±6 ”m AL-IOSs) (P=.002) and TRIOS 4 (93 ±18 ”m cIOSs; 76 ±18 ”m sIOSs; 107 ±13 ”m AL-IOSs) (P=.001) for all techniques. In addition, no significant differences were found between the techniques by using iTero 5D or Primescan (P=.348 and P=.059, respectively). Conclusions: The cIOSs, sIOSs, and AL-IOSs techniques showed similar trueness. The IOS used influenced the trueness of complete-arch digital implant scans.info:eu-repo/semantics/acceptedVersio

    Klinische, kontrollierte, prospektive Kohortenstudie zur Untersuchung der EffektivitÀt einer azellulÀren dreidimensionalen Kollagenmatrix zur Verdickung der fazialen Mukosa nach Sofortimplantation

    Get PDF
    Connective tissue grafts have become a standard for compensating horizontal volume loss in immediate implant placement. The use of new biomaterials like acellular matrices may avoid the need to harvest autogenous grafts, yielding less postoperative morbidity. This randomized comparative study evaluated the clinical outcomes following extraction and immediate implant placement in conjunction with anorganic bovine bone mineral (ABBM) and the use of a porcine acellular dermal matrix (ADM) vs an autogenous connective tissue graft (CTG) in the anterior maxilla. Twenty patients (11 men, 9 women) with a mean age of 48.9 years (range: 21 to 72 years) were included in the study and randomly assigned to either the test (ADM) or control (CTG) group. They underwent tooth extraction and immediate implant placement together with ABBM for socket grafting and either ADM or CTG for soft tissue augmentation. Twelve months after implant placement, the cases were evaluated clinically and volumetrically. All implants achieved osseointegration and were restored. The average horizontal change of the ridge dimension at 1 year postsurgery was –0.55 ± 0.32 mm for the ADM group and –0.60 ± 0.49 mm for the CTG group. Patients of the ADM group reported significantly less postoperative pain. Using xenografts for hard and soft tissue augmentation in conjunction with immediate implant placement showed no difference in the volume change in comparison to an autogenous soft tissue graft, and showed significantly less postoperative morbidity. Int J Periodontics Restorative Dent 2022;42:381–390. doi: 10.11607/prd.563

    Intermediate-mass black holes and the fundamental plane of black hole accretion

    Full text link
    We present new 5 GHz VLA observations of a sample of 8 active intermediate-mass black holes with masses 104.9<M<106.1 M⊙10^{4.9} < M < 10^{6.1}\ M_{\odot} found in galaxies with stellar masses M∗<3×109 M⊙M_{*} < 3 \times 10^{9}\ M_{\odot}. We detected 5 of the 8 sources at high significance. Of the detections, 4 were consistent with a point source, and one (SDSS J095418.15+471725.1, with black hole mass M<105 M⊙M < 10^{5}\ M_{\odot}) clearly shows extended emission that has a jet morphology. Combining our new radio data with the black hole masses and literature X-ray measurements, we put the sources on the fundamental plane of black hole accretion. We find that the extent to which the sources agree with the fundamental plane depends on their star-forming/composite/AGN classification based on optical narrow emission line ratios. he single star-forming source is inconsistent with the fundamental plane. The three composite sources are consistent, and three of the four AGN sources are inconsistent with the fundamental plane. We argue that this inconsistency is genuine and not a result of misattributing star-formation to black hole activity. Instead, we identify the sources in our sample that have AGN-like optical emission line ratios as not following the fundamental plane and thus caution the use of the fundamental plane to estimate masses without additional constraints, such as radio spectral index, radiative efficiency, or the Eddington fraction.Comment: Accepted for publication in Monthly Notices of the Royal Astronomical Society. 9 pages, 2 figures. Images can be accessed in fits format from https://doi.org/10.7302/3100-6e6

    Fracture strength of zirconia implant abutments on narrow diameter implants with internal and external implant abutment connections: A study on the titanium resin base concept

    Full text link
    BACKGROUND There is limited knowledge regarding the strength of zirconia abutments with internal and external implant abutment connections and zirconia abutments supported by a titanium resin base (Variobase, Straumann) for narrow diameter implants. OBJECTIVES To compare the fracture strength of narrow diameter abutments with different types of implant abutment connections after chewing simulation. MATERIAL AND METHODS Hundred and twenty identical customized abutments with different materials and implant abutment connections were fabricated for five groups: 1-piece zirconia abutment with internal connection (T1, Cares-abutment-Straumann BL-NC implant, Straumann Switzerland), 1-piece zirconia abutment with external hex connection (T2, Procera abutment-Branemark NP implant, Nobel Biocare, Sweden), 2-piece zirconia abutments with metallic insert for internal connection (T3, Procera abutment-Replace NP implant, Nobel Biocare), 2-piece zirconia abutment on titanium resin base (T4, LavaPlus abutment-VarioBase-Straumann BL-NC implant, 3M ESPE, Germany) and 1-piece titanium abutment with internal connection (C, Cares-abutment-Straumann BL-NC implant, Straumann, Switzerland). All implants had a narrow diameter ranging from 3.3 to 3.5 mm. Sixty un-restored abutments and 60 abutments restored with glass-ceramic crowns were tested. Mean bending moments were compared using ANOVA with p-values adjusted for multiple comparisons using Tukey's procedure. RESULTS The mean bending moments were 521 ± 33 Ncm (T4), 404 ± 36 Ncm (C), 311 ± 106 Ncm (T1) 265 ± 22 Ncm (T3) and 225 ± 29 (T2) for un-restored abutments and 278 ± 84 Ncm (T4), 302 ± 170 Ncm (C), 190 ± 55 Ncm (T1) 80 ± 102 Ncm (T3) and 125 ± 57 (T2) for restored abutments. For un-restored abutments, C and T4 had similar mean bending moments, significantly higher than those of the three other groups (p < .05). Titanium abutments (C) had significantly higher bending moments than identical zirconia abutments (T1) (p < .05). Zirconia abutments (T1) with internal connection had higher bending moments than zirconia abutments with external connection (T2) (p < .05). For all test groups, the bending moments were significantly reduced when restored with all-ceramic crowns. CONCLUSIONS For narrow diameter abutments, the fracture strength of 2-piece internal connected zirconia abutments fixed on titanium resin bases was similar to those obtained for 1-piece titanium abutments. Narrow diameter zirconia abutments with internal connection exhibited higher fracture strength than zirconia abutments with an external connection. Titanium abutments with an internal connection were significantly stronger than identical zirconia abutments

    Group 2 ITI Consensus Report: Technological developments in implant prosthetics

    Get PDF
    Objectives Group‐2 reviewed the scientific evidence in the field of «Technology». Focused research questions were: (1) additive versus subtractive manufacturing of implant restorations; (2) survival, complications, and esthetics comparing prefabricated versus customized abutments; and (3) survival of posterior implant‐supported multi‐unit fixed dental prostheses.Materials and MethodsLiterature was systematically screened, and 67 publications could be critically reviewed following PRISMA guidelines, resulting in three systematic reviews. Consensus statements were presented to the plenary where after modification, those were accepted.ResultsAdditively fabricated implant restorations of zirconia and polymers were investigated for marginal/internal adaptation and mechanical properties without clear results in favor of one technology or material. Titanium base abutments for screw‐retained implant single crowns compared to customized abutments did not show significant differences concerning 1‐year survival. PFM, veneered and monolithic zirconia implant‐supported multi‐unit posterior fixed dental prostheses demonstrated similar high 3‐year survival rates, whereas veneered restorations exhibited the highest annual ceramic fracture and chipping rates.ConclusionsFor interim tooth‐colored implant single crowns both additive and subtractive manufacturing are viable techniques. The clinical performance of additively produced restorations remains to be investigated. Implant single crowns on titanium base abutments show similar clinical performance compared to other type of abutments; however, long‐term clinical data from RCTs are needed. The abutment selection should be considered already during the planning phase. Digital planning facilitates 3D visualization of the prosthetic design including abutment selection. In the posterior area, monolithic zirconia is recommended as the material of choice for multi‐unit implant restorations to reduce technical complications

    Fabrication, workflow and delivery of reconstruction: Summary and consensus statements of group 4. The 6th EAO Consensus Conference 2021.

    Get PDF
    Objectives: To report assessments of four systematic reviews (SRs) on (i) clinical outcomes of all-ceramic implant-supported crowns (iSCs), (ii) production time, effectiveness, and costs of computer-assisted manufacturing (CAM), (iii) computer-assisted implant planning and surgery (CAIPS) time and costs, and (iv) patient-reported outcome measures (PROMS). Material and methods: An author group consisting of experienced clinicians and content experts discussed and evaluated the SRs and formulated consensus on the main findings, statements, clinical recommendations, and need for future research. Results: All four SRs were conducted and reported according to PRISMA and detailed comprehensive search strategies in at least three bibliometric databases and hand searching. The search strategies were deemed reproducible. Variation was noted regarding language restrictions and inclusion of grey literature, but the search comprehensiveness appeared persuasive. The SRs included bias risk assessments of the primary studies, and their study methodology impacted the interpretations of the extracted data. Conclusions: (i) There is limited evidence (49 NRCT) showing that veneered and monolithic all-ceramic iSCs have excellent outcomes observed up to 3 years. (ii) There is no evidence evaluating production time and effectiveness comparing subtractive and additive CAM of implant models, abutments and crowns. (iii) There is limited evidence (4 RCT) that CAIPS involves more time and costs when considering the entire workflow and for diagnostics, manufacturing, and insertion of the restoration. Time seems to be the decisive factor for higher costs. (iv) Patients' comfort increases when optical compared to conventional impressions are used for fabricating iSCs and short-span FPDs (2 RCT, 5 NRCT)

    Plato's Protagoras nach seinem innern Zusammenhange entwickelt

    No full text
    von G. Fehmer, Conr.In Fraktu

    Theaeteti Platonici enarratio

    No full text
    scripsit G. Fehmer, Conrecto
    • 

    corecore