1,846 research outputs found

    A study of elastic and plastic stress concentration factors due to notches and fillets in flat plates

    Get PDF
    Six large 24s-t3 aluminum-alloy-sheet specimens containing various notches or fillets were tested in tension to determine their stress concentration factors in both the elastic and plastic ranges. The elastic stress concentration factors were found to be slightly higher than those calculated by Neuber's method and those obtained photoelastically by Frocht. The results showed further that the stress concentration factor decreases as strains at the discontinuity enter the plastic range. A generalization of Stowell's relation for the plastic stress concentration factor at a circular hole in an infinite plate was applied to the specimen shapes tested and gave good agreement with test results

    Respiratory and cardiovascular responses to walking down a traffic-polluted road compared with walking in a traffic-free area in participants aged 60 years and older with chronic lung or heart disease and age-matched healthy controls: a randomised, crossover study

    Get PDF
    Background Long-term exposure to pollution can lead to an increase in the rate of decline of lung function, especially in older individuals and in those with chronic obstructive pulmonary disease (COPD), whereas shorter-term exposure at higher pollution levels has been implicated in causing excess deaths from ischaemic heart disease and exacerbations of COPD. We aimed to assess the effects on respiratory and cardiovascular responses of walking down a busy street with high levels of pollution compared with walking in a traffic-free area with lower pollution levels in older adults. Methods In this randomised, crossover study, we recruited men and women aged 60 years and older with angiographically proven stable ischaemic heart disease or stage 2 Global initiative for Obstructive Lung Disease (GOLD) COPD who had been clinically stable for 6 months, and age-matched healthy volunteers. Individuals with ischaemic heart disease or COPD were recruited from existing databases or outpatient respiratory and cardiology clinics at the Royal Brompton & Harefield NHS Foundation Trust and age-matched healthy volunteers using advertising and existing databases. All participants had abstained from smoking for at least 12 months and medications were taken as recommended by participants' doctors during the study. Participants were randomly assigned by drawing numbered disks at random from a bag to do a 2 h walk either along a commercial street in London (Oxford Street) or in an urban park (Hyde Park). Baseline measurements of participants were taken before the walk in the hospital laboratory. During each walk session, black carbon, particulate matter (PM) concentrations, ultrafine particles, and nitrogen dioxide (NO2) concentrations were measured. Findings Between October, 2012, and June, 2014, we screened 135 participants, of whom 40 healthy volunteers, 40 individuals with COPD, and 39 with ischaemic heart disease were recruited. Concentrations of black carbon, NO2, PM10, PM2.5, and ultrafine particles were higher on Oxford Street than in Hyde Park. Participants with COPD reported more cough (odds ratio [OR] 1·95, 95% CI 0·96–3·95; p<0·1), sputum (3·15, 1·39–7·13; p<0·05), shortness of breath (1·86, 0·97–3·57; p<0·1), and wheeze (4·00, 1·52–10·50; p<0·05) after walking down Oxford Street compared with Hyde Park. In all participants, irrespective of their disease status, walking in Hyde Park led to an increase in lung function (forced expiratory volume in the first second [FEV1] and forced vital capacity [FVC]) and a decrease in pulse wave velocity (PWV) and augmentation index up to 26 h after the walk. By contrast, these beneficial responses were attenuated after walking on Oxford Street. In participants with COPD, a reduction in FEV1 and FVC, and an increase in R5–20 were associated with an increase in during-walk exposure to NO2, ultrafine particles and PM2.5, and an increase in PWV and augmentation index with NO2 and ultrafine particles. In healthy volunteers, PWV and augmentation index were associated both with black carbon and ultrafine particles. Interpretation Short-term exposure to traffic pollution prevents the beneficial cardiopulmonary effects of walking in people with COPD, ischaemic heart disease, and those free from chronic cardiopulmonary diseases. Medication use might reduce the adverse effects of air pollution in individuals with ischaemic heart disease. Policies should aim to control ambient levels of air pollution along busy streets in view of these negative health effects

    Intra-aortic balloon counterpulsation in US and non-US centres: results of the Benchmark® Registry

    Get PDF
    Aims To examine differences in patient characteristics and outcomes in 19 636 patients enrolled in the USA and 3027 patients enrolled in other countries undergoing intra-aortic balloon pump (IABP) counterpulsation. Methods and results Indications for IABP use; a larger percentage of US patients were identified as ‘early support and stabilization for angiography or angioplasty' (21.1% US vs 11.8% non-US), and ‘pre-operative support for high-risk CABG' (15.9% vs 6.6%). A smaller percentage of US patients vs non-US patients were identified as ‘weaning from cardiopulmonary bypass' (14.3% vs 28.2%), and ‘refractory ventricular failure' (6.2% vs 9.8%). One out of five patients in both groups was listed as ‘cardiogenic shock' (18.9% US vs 20.2% non-US). All cause, risk-adjusted, in-hospital mortality (20.1% vs 28.7%; P<0.001), and mortality with IABP in place (10.8% vs 18.0%; P<0.001) were lower at US vs non-US sites. In both US and non-US institutions, IABP associated complication rates, such as IABP-related mortality (0.05% vs 0.07%), major limb ischaemia (0.9% vs 0.8%), and severe bleeding (0.9% vs 0.8%), were low. Conclusions IABP counterpulsation is deployed at an earlier clinical stage in US patients. Mortality rates are higher for non-US patients, particularly for patients with non-surgery cardiac interventions, even after adjusting for risk factors. Complication rates were low. Physicians should therefore not be reluctant to use IABP in high-risk patients undergoing cardiac procedure

    Spatial Division Multiplexed Microwave Signal processing by selective grating inscription in homogeneous multicore fibers

    Full text link
    [EN] The use of Spatial Division Multiplexing for Microwave Photonics signal processing is proposed and experimentally demonstrated, for the first time to our knowledge, based on the selective inscription of Bragg gratings in homogeneous multicore fibers. The fabricated devices behave as sampled true time delay elements for radiofrequency signals offering a wide range of operation possibilities within the same optical fiber. The key to processing flexibility comes from the implementation of novel multicavity configurations by inscribing a variety of different fiber Bragg gratings along the different cores of a 7-core fiber. This entails the development of the first fabrication method to inscribe high-quality gratings characterized by arbitrary frequency spectra and located in arbitrary longitudinal positions along the individual cores of a multicore fiber. Our work opens the way towards the development of unique compact fiber-based solutions that enable the implementation of a wide variety of 2D (spatial and wavelength diversity) signal processing functionalities that will be key in future fiber-wireless communications scenarios. We envisage that Microwave Photonics systems and networks will benefit from this technology in terms of compactness, operation versatility and performance stability.We thank Prof. Jose Capmany for the thoughtful discussions and recommendations that greatly contribute to this work. This research was supported by the Spanish MINECO Projects TEC2014-60378-C2-1-R and TEC2015-62520-ERC, the Valencian Research Excellency Award Program GVA PROMETEO 2013/012, the Spanish MECD FPU Scholarship (FPU13/04675) for J. Hervas, and the Spanish MINECO Ramon y Cajal Program (RYC-2014-16247) for I. Gasulla.Gasulla Mestre, I.; Barrera Vilar, D.; Hervás-Peralta, J.; Sales Maicas, S. (2017). Spatial Division Multiplexed Microwave Signal processing by selective grating inscription in homogeneous multicore fibers. Scientific Reports. 7(41727):1-10. https://doi.org/10.1038/srep41727S110741727Samsung Electronics Co, “5G Vision”, available at http://www.samsung.com/global/business-images/insights/2015/Samsung-5G-Vision-0.pdf (2015).Technology Focus on Microwave Photonics. Nat. Photonics 5, 723 (2011).J. Capmany, J. Mora, I. Gasulla, J. Sancho, J. Lloret & S. Sales . Microwave photonic signal processing. IEEE J. Lightw. Technol. 31, 571–586 (2013).Y. Long & J. Wang . Ultra-high peak rejection notch microwave photonic filter using a single silicon microring resonator. Opt. Express 23, 17739–17750 (2015).Y. Long & J. Wang . All-optical tuning of a nonlinear silicon microring assisted microwave photonic filter: theory and experiment. Opt. Express 23, 17758–17771 (2015).Y. Long, L. Zhou & J. Wang . Photonic-assisted microwave signal multiplication and modulation using a silicon Mach–Zehnder modulator. Sci. Reports 6, 20215 (2016).J. Sancho, J. Bourderionnet, J. Lloret, S. Combrié, I. Gasulla, S. Xavier, S. Sales, P. Colman, G. Lehoucq, D. Dolfi, J. Capmany & A. De Rossi . Integrable microwave filter based on a photonic crystal delay line. Nat. Commun. 3, 1075 (2012).F. Ohman, K. Yvind & J. Mørk . Slow Light in a Semiconductor Waveguide for True-Time Delay Applications in Microwave Photonics. IEEE Photon. Technol. Lett. 19, 1145–1157 (2007).P. A. Morton & J. B. Khurgin. Microwave photonic delay line with separate tuning of the optical carrier. IEEE Photon. Technol. Lett. 21, 1686–1688 (2009).D. Marpaung, C. Roeloffzen, R. Heideman, A. Leinse, S. Sales & J. Capmany . Integrated microwave photonics. Lasers Photon. Rev. 7, 506–538 (2013).I. Gasulla & J. Capmany . Microwave photonics applications of multicore fibers. Photonics J. 4, 877–888 (2012).S. Garcia & I. Gasulla . Design of Heterogeneous Multicore fibers as sampled True Time Delay Lines. Opt. Lett. 40, 621–624 (2015).F. Zeng & J. Yao . All-optical microwave filters using uniform fiber Bragg gratings with identical reflectivities. IEEE J. Lightw. Technol. 23, 1410 (2005).C. Wang & J. Yao . Fiber Bragg gratings for microwave photonics subsystems. Opt. Express 21, 22868–22884 (2013).I. Gasulla, D. Barrera & S. Sales . Microwave photonic devices based on multicore fibers. 16th International Conference on Transparent Optical Networks (ICTON), Graz, Austria, 2014.I. Gasulla, D. Barrera, J. Hervás, S. García & S. Sales . Multi-cavity Microwave Photonics devices built upon multicore fibres. 18th International Conference on Transparent Optical Networks (ICTON), Trento (Italy), pp. 1–4, 2016.K. O. Hill & G. Meltz . Fiber Bragg grating technology fundamentals and overview. IEEE J. Lightw. Technol. 15, 1263–1276 (1997).T. Erdogan . Fiber grating spectra. IEEE J. Lightw. Technol. 15, 1277–1294 (1997).D. Barrera, I. Gasulla & S. Sales . Multipoint two-dimensional curvature optical fiber sensor based on a non-twisted homogeneous four-core fiber. IEEE J. Lightw. Technol. 33, 2445–2450 (2015).T. Birks, B. Mangan, A. Diez, J. Cruz, S. Leon-Saval, J. Bland-Hawthorn & D. Murphy . Multicore optical fibres for astrophotonics. In CLEO/Europe and EQEC 2011 Conference Digest, OSA Technical Digest (CD)d (Optical Society of America, 2011), paper JSIII2_1.C. Wang, Z. Yan, Q. Sun, Z. Sun, C. Mou, J. Zhang, A. Badmos & L. Zhang . Fibre Bragg gratings fabrication in four core fibres. Proc. SPIE 9886, Micro-Structured and Specialty Optical Fibres IV, 98860H (2016).M. J. Cole, W. H. Loh, R. I. Laming, M. N. Zervas & S. Barcelos . Moving fibre/phase mask-scanning beam technique for enhanced flexibility in producing fibre gratings with uniform phase mask. Electron. Lett. 31, 1488–1490 (1995).M. Gallagher & U. Österberg . Time resolved 3.10 eV luminescence in germanium-doped silica glass. Appl. Phys. Lett. 63, 2987–2988 (1993).T. Komukai & M. Nakazawa . Fabrication of high-quality long fiber Bragg grating by monitoring 3.1 eV radiation (400 nm) from GeO defects. IEEE Photon. Tech. Lett. 8, 1495–1497 (1996).R. R. Thomson, H. T. Bookey, N. D. Psaila, A. Fender, S. Campbell, W. N. MacPherson, J. S. Barton, D. T. Reid & A. K. Kar . Ultrafast-laser inscription of a three dimensional fan-out device for multicore fiber coupling applications. Opt. Express 15, 11691–11697 (2007)

    Signature Movements Lead to Efficient Search for Threatening Actions

    Get PDF
    The ability to find and evade fighting persons in a crowd is potentially life-saving. To investigate how the visual system processes threatening actions, we employed a visual search paradigm with threatening boxer targets among emotionally-neutral walker distractors, and vice versa. We found that a boxer popped out for both intact and scrambled actions, whereas walkers did not. A reverse correlation analysis revealed that observers' responses clustered around the time of the “punch", a signature movement of boxing actions, but not around specific movements of the walker. These findings support the existence of a detector for signature movements in action perception. This detector helps in rapidly detecting aggressive behavior in a crowd, potentially through an expedited (sub)cortical threat-detection mechanism

    Attentive Learning of Sequential Handwriting Movements: A Neural Network Model

    Full text link
    Defense Advanced research Projects Agency and the Office of Naval Research (N00014-95-1-0409, N00014-92-J-1309); National Science Foundation (IRI-97-20333); National Institutes of Health (I-R29-DC02952-01)
    corecore