2,102 research outputs found

    Evidence for virtual Compton scattering from the proton

    Get PDF
    In virtual Compton scattering an electron is scattered off a nucleon such that the nucleon emits a photon. We show that these events can be selected experimentally, and present the first evidence for virtual Compton scattering from the proton in data obtained at the Stanford Linear Accelerator Center. The angular and energy dependence of the data is well described by a calculation that includes the coherent sum of electron and proton radiation

    Effects of transport age (14 d vs. 28 d of age) on blood total cholesterol, insulin and IGF-1 concentrations of veal calves.

    Get PDF
    The main aim of the current study was to find biomarkers of health in calves transported at different ages. The selected blood parameters were total cholesterol, insulin and IGF-1 and the longitudinal study investigated whether or not these concentrations were different between calves that were transported from the dairy farm to the veal farm at 14 d or 28 d of age. Relationships between these blood variables and health characteristics of veal calves were investigated. In a 34-wk study period, a total of 683 calves originating from 13 Dutch dairy farms were transported at an age of 14 or 28 d to 8 Dutch veal farms. Calves were blood sampled the first wk after birth (mean and SD: 4.4 ± 2.1 d), a day before transport (mean and SD: 25.8 ± 7.3 d) and in wk 2 post-transport (mean and SD: 36.7 ± 12.2 d). In these samples, insulin, IGF-1 and total cholesterol were determined and analyzed with a linear mixed model (LMM). Individual medical treatments were recorded from birth until the day of transport at the dairy farm, and from the moment of arrival at the veal farm until slaughter, and analyzed as a binary response variable (calf treated or not) with a generalized linear mixed model. Fecal (calf with or without loose or liquid manure) and navel (calves with or without swollen and inflamed navel) scores measured during a single visit in wk 2 post-transport were also analyzed as binary response variables, whereas carcass weights at slaughter age were analyzed with a LMM. Cholesterol, insulin and IGF-1 were included as covariates in the previous models to test their relationships with the likelihood of calves being medically treated, fecal and navel scores, and carcass weights. One day before transport 28 d-old calves had higher blood cholesterol (Δ = 0.40 mmol/l) and IGF-1 (Δ = 53.6 ng/ml) concentrations, and evidence of higher insulin (Δ = 12.2 µU/ml) compared with 14 d-old calves. In wk 2 post-transport, 28-d old calves had higher blood IGF-1 (Δ = 21.1 ng/ml), with evidence of higher insulin (Δ = 12.2 µU/ml) concentrations compared with 14-d old calves. Cholesterol concentration measured one day before transport and in wk 2 post-transport had a positive relationship with carcass weight at slaughter (β = 4.8 and 7.7 kg/mmol/l, respectively). Blood cholesterol concentration in wk 2 post-transport was negatively associated with the fecal score measured at the same sampling moment (β = -0.55/mmol/l), with the likelihood of a calf of being treated with antibiotics (β = -0.36/mmol/l) and other medicines (β = -0.45/mmol/l) at the veal farm. Blood IGF-1 concentration in wk 2 post-transport was negatively associated with the likelihood of a calf of being treated with antibiotics and other medicines (both β = -0.01/ng/ml) at the veal farm, and with fecal score recorded in wk 2 post-transport (β = -0.004/ng/ml). When looking at the blood indicators, it appeared that calves transported at 28 d of age were more developed compared with 14 d old calves, thus transport at an older age might be more beneficial for the animals. It can be concluded that both blood cholesterol and IGF-1 concentrations seemed to be valuable biomarkers of health and energy availability in veal calves

    Home measures of anxiety, avoidant coping and defence as predictors of anxiety, heart rate and skin conductance level just before invasive cardiovascular procedures

    Get PDF
    The question was whether anxiety, heart rate and skin conductance level just before invasive cardiac procedures could be predicted by anxiety related measures obtained at patients homes approximately 3 weeks before treatment. Trait measures of avoidant coping and defence were provided by sixty-three male and thirty-three female patients who were scheduled for a diagnostic or interventional heart catheterization. In hospital physiological measures were registered continously during a 20 min interview and subsequently patients reported their anxiety. Results with hierarchical regres

    A multifrequency notch filter for millimeter wave plasma diagnostics based on photonic bandgaps on corrugated circular waveguides

    Get PDF
    Sensitive millimeter wave diagnostics need often to be protected against unwanted radiation like, for example, stray radiation from high power Electron Cyclotron Heating applied in nuclear fusion plasmas. A notch filter based on a waveguide Bragg reflector (photonic band-gap) may provide several stop bands of defined width within up to two standard waveguide frequency bands. A Bragg reflector that reflects an incident fundamental TE11 into a TM1n mode close to cutoff is combined with two waveguide tapers to fundamental waveguide diameter. Here the fundamental TE11 mode is the only propagating mode at both ends of the reflector. The incident TE11 mode couples through the taper and is converted to the high order TM1n mode by the Bragg structure at the specific Bragg resonances. The TM1n mode is trapped in the oversized waveguide section by the tapers. Once reflected at the input taper it will be converted back into the TE11 mode which then can pass through the taper. Therefore at higher order Bragg resonances, the filter acts as a reflector for the incoming TE11 mode. Outside of the Bragg resonances the TE11 mode can propagate through the oversized waveguide structure with only very small Ohmic attenuation compared to propagating in a fundamental waveguide. Coupling to other modes is negligible in the non-resonant case due to the small corrugation amplitude (typically 0.05·λ0, where λ0 is the free space wavelength). A Bragg reflector for 105 and 140 GHz was optimized by mode matching (scattering matrix) simulations and manufactured by SWISSto12 SA, where the required mechanical accuracy of ± 5 μm could be achieved by stacking stainless steel rings, manufactured by micro-machining, in a high precision guiding pipe. The two smooth-wall tapers were fabricated by electroforming. Several measurements were performed using vector network analyzers from Agilent (E8362B), ABmm (MVNA 8-350) and Rohde&Schwarz (ZVA24) together with frequency multipliers. The stop bands around 105 GHz (- 55dB) and 140 GHz (-60dB) correspond to the TE11-TM12 and TE11-TM13 Bragg resonances. Experiments are in good agreement with theory

    The Polarized 3-He Target

    Get PDF
    This research was sponsored by the National Science Foundation Grant NSF PHY-931478

    Interventional Cardiology in Europe 1993

    Get PDF
    An annual survey on cardiac interventions in Europe is performed by the working group on Coronary Circulation of the European Society of Cardiology with the help of the national societies of cardiology. A questionnaire about cardiac interventions in 1993 was mailed to a representative of the national societies of 35 members of the European Society of Cardiology. The data collection of coronary interventions was delayed by slow backreporting and from 10 of the 35 national members data were missing or grossly incomplete. They were excluded from the analysis. Coronary anglography A total of 756 822 coronary angiograms were reported resulting in an incidence of 1146 ± 1024 per 106 inhabitants, ranging from 24 (Romania) to 3499 (Germany). This represents an increase of 12% compared to 1992. Germany (279 882 cases), France (157 237), the United Kingdom (77 000), Italy (44 934) and Spain (37 591) registered 79% of all the coronary angiograms performed. Percutaneous transluminal coronary angioptasty A total of 183 728 percutaneous transluminal coronary angioplasty cases were reported in 1993, 24% more than in 1992. On average, they accounted for 18 ± 7% (range 8 (Romania) to 35% (Sweden)) of the coronary angiograms. Most of these percutaneous transluminal coronary angioplasties (82%) were confined to a single vessel. In 13% only, percutaneous transluminal coronary angioplasty took place immediately after the diagnostic study. Adjusted per capita, Germany ranks first with 873 percutaneous transluminal coronary angioplasties per 106 inhabitants, followed by France (737), Holland (725), Belgium (713), and Switzerland (665). The European mean of percutaneous transluminal coronary angioplasties per 106 inhabitants was 270 ± 279, representing an increase of 14% compared with 1992. A major in-hospital complication was reported in 3.8% of the patients undergoing percutaneous transluminal coronary angioplasty: 0.6% hospital deaths, 1.5% emergency coronary artery bypass graftings, and 1.7% myocardial infarctions. New devices In 1993 stents were implanted in 6444 patients (3.5% of all percutaneous transluminal coronary angioplasty patients), equally distributed between bail-out situations (53%) and elective procedures. The 14 stent implanting countries showed a mean increase in the incidence of coronary stenting of 53% compared with 1992. Other interventional devices were applied in 7045 cases, i.e. 3.8% of all percutaneous transluminal coronary angioplasty cases. Coronary ultrasound (2194 cases) and coronary angioscopy (380 cases) were performed infrequently. Non-coronary interventions Valvuloplasties were the most frequently performed non-coronary interventions. Six European countries performed more than 300 valvuloplasties each in 1993. Most of them were mitral valvuloplasties in southern countries. Conclusions Although partial backreporting might bias conclusions, several findings of this survey are noteworthy for the participating countries: The number of percutaneous transluminal coronary angioplasties is universally increasing. There is an extremely wide range of coronary angiography and percutaneous transluminal coronary angioplasties performed per population. The most common additional procedure is a stent implantation while other new devices are only rarely applied. Mitral valvuloplasty is the most frequently performed non-coronary intervention. (Eur Heart J 1996; 17: 1318-1328
    corecore