147 research outputs found

    Implementation and experience with luminosity levelling with offset beam

    Full text link
    The practice of luminosity levelling with an offset beam has been used as a routine operation in the LHC since 2011. This paper will describe how it has been implemented and what has been the operational experience with the system.Comment: 5 pages, contribution to the ICFA Mini-Workshop on Beam-Beam Effects in Hadron Colliders, CERN, Geneva, Switzerland, 18-22 Mar 201

    Fitting Algorithms for Optical and Beam Parameters in Transfer Lines with Application to the LHC Injection Line T12

    Get PDF
    As part of the commissioning with beam of the transfer line TI2 and TI8 from the SPS to the LHC [1], a series of optics measurements has been conducted. The paper presents the results in terms of Twiss parameters (including the dispersion), emittance and momentum spread obtained from the combination of trajectory and beam profile measurements. Profiting from the redundancy of monitors, there is a possibility of applying different fitting algorithms to retrieve beam parameters and to extract information on the optics of the line. The results from the different fit methods applied to the data will be compared with the expected values and cross-checked with independent measurements

    Phase Shift Sequences for an Adding Interferometer

    Get PDF
    Cosmic microwave background (CMB) polarimetry has the potential to provide revolutionary advances in cosmology. Future experiments to detect the very weak B mode signal in CMB polarization maps will require unprecedented sensitivity and control of systematic errors. Bolometric interferometry may provide a way to achieve these goals. In a bolometric interferometer (or other adding interferometer), phase shift sequences are applied to the inputs in order to recover the visibilities. Noise is minimized when the phase shift sequences corresponding to all visibilities are orthogonal. We present a systematic method for finding sequences that produce this orthogonality, approximately minimizing both the length of the time sequence and the number of discrete phase shift values required. When some baselines are geometrically equivalent, we can choose sequences that read out those baselines simultaneously, which has been shown to improve signal to noise ratio.Comment: 8 pages, 1 figur

    Energy Linearity and Resolution of the ATLAS Electromagnetic Barrel Calorimeter in an Electron Test-Beam

    Get PDF
    A module of the ATLAS electromagnetic barrel liquid argon calorimeter was exposed to the CERN electron test-beam at the H8 beam line upgraded for precision momentum measurement. The available energies of the electron beam ranged from 10 to 245 GeV. The electron beam impinged at one point corresponding to a pseudo-rapidity of eta=0.687 and an azimuthal angle of phi=0.28 in the ATLAS coordinate system. A detailed study of several effects biasing the electron energy measurement allowed an energy reconstruction procedure to be developed that ensures a good linearity and a good resolution. Use is made of detailed Monte Carlo simulations based on Geant which describe the longitudinal and transverse shower profiles as well as the energy distributions. For electron energies between 15 GeV and 180 GeV the deviation of the measured incident electron energy over the beam energy is within 0.1%. The systematic uncertainty of the measurement is about 0.1% at low energies and negligible at high energies. The energy resolution is found to be about 10% sqrt(E) for the sampling term and about 0.2% for the local constant term

    First Results for the Beam Commissioning of the CERN Multi-Turn Extraction

    Get PDF
    The Multi-Turn Extraction (MTE), a new type of extraction based on beam trapping inside stable islands in horizontal phase space, has been commissioned during the 2008 run of the CERN Proton Synchrotron. Both singleand multi-bunch beams with a total intensity up to 1.4 1013 protons have been extracted with efficiencies up to 98%. Furthermore, injection tests in the CERN Super Proton Synchrotron were performed, with the beam then accelerated and extracted to produce neutrinos for the CERN Neutrino-to-Gran Sasso experiments. The results of the extensive measurement campaign are presented and discussed in detail

    A retrospective analysis of bilateral fractures over sixteen years: localisation and variation in treatment of second hip fractures

    Get PDF
    The aim of this study was the evaluation of contralateral hip fractures after a previous hip fracture. For this retrospective analysis patients were selected from the database of the LUMC, a teaching hospital in the south-west of the Netherlands. We analyzed all patients with a second fracture of a hip between 1992 and 2007. The exclusion criteria were high impact trauma and patients with diseases or medication known to have a negative effect on bone metabolism. A total of 1,604 hip fractures were identified. The possible predictive factors for the second fracture and descriptive statistics related to surgery (Hb and HT before and after the operation, total amount of intra- and postoperative blood loss, type of osteosynthesis, complications, time of death after the last fracture, time between arrival in the hospital and operation and hospital stay for both fractures) were recorded. A total of 32 second hip fractures were identified (2%) at a mean of 27.5 (SD 28.9) months after the initial hip fracture. The mean age at the first fracture was 77.2 years (SD 11.7), and 27 of 32 patients were female. Of these 32 patients (64 bilateral hip fractures), 32 fractures were intracapsular (1 femoral neck, 31 subcapital) and 32 were extracapsular fractures (6 subtrochanteric, 26 transtrochanteric). Although 24 of the 32 patients had identical first and second hip fractures, only eight out of 32 hips were treated with the same implants. There was a significant difference in Singh index between both hips at the time of the first fracture. There was also a significant difference in Singh index between the hip which was not fractured compared with its subsequent index when it was broken. All other studied patient and fracture characteristics were not significantly different. In this population the percentage of second hip fractures was relatively low compared to other studies. The choice of implants in this study shows that implants were chosen randomly. Because there is a significant difference in the Singh index during first and second hip fracture, osteoporosis medication might help reduce the incidence of second hip fractures

    High Burden of Non-Influenza Viruses in Influenza-Like Illness in the Early Weeks of H1N1v Epidemic in France

    Get PDF
    BACKGROUND: Influenza-like illness (ILI) may be caused by a variety of pathogens. Clinical observations are of little help to recognise myxovirus infection and implement appropriate prevention measures. The limited use of molecular tools underestimates the role of other common pathogens. OBJECTIVES: During the early weeks of the 2009-2010 flu pandemic, a clinical and virological survey was conducted in adult and paediatric patients with ILI referred to two French University hospitals in Paris and Tours. Aims were to investigate the different pathogens involved in ILI and describe the associated symptoms. METHODS: H1N1v pandemic influenza diagnosis was performed with real time RT-PCR assay. Other viral aetiologies were investigated by the molecular multiplex assay RespiFinder19®. Clinical data were collected prospectively by physicians using a standard questionnaire. RESULTS: From week 35 to 44, endonasal swabs were collected in 413 patients. Overall, 68 samples (16.5%) were positive for H1N1v. In 13 of them, other respiratory pathogens were also detected. Among H1N1v negative samples, 213 (61.9%) were positive for various respiratory agents, 190 in single infections and 23 in mixed infections. The most prevalent viruses in H1N1v negative single infections were rhinovirus (62.6%), followed by parainfluenza viruses (24.2%) and adenovirus (5.3%). 70.6% of H1N1v cases were identified in patients under 40 years and none after 65 years. There was no difference between clinical symptoms observed in patients infected with H1N1v or with other pathogens. CONCLUSION: Our results highlight the high frequency of non-influenza viruses involved in ILI during the pre-epidemic period of a flu alert and the lack of specific clinical signs associated with influenza infections. Rapid diagnostic screening of a large panel of respiratory pathogens may be critical to define and survey the epidemic situation and to provide critical information for patient management

    The LHC Injection Tests

    Get PDF
    A series of LHC injection tests was performed in August and September 2008. The first saw beam injected into sector 23; the second into sectors 78 and 23; the third into sectors 78-67 and sectors 23-34-45. The fourth, into sectors 23-34-45, was performed the evening before the extended injection test on the 10th September which saw both beams brought around the full circumference of the LHC. The tests enabled the testing and debugging of a number of critical control and hardware systems; testing and validation of instrumentation with beam for the first time; deployment, and validation of a number of measurement procedures. Beam based measurements revealed a number of machine configuration issues that were rapidly resolved. The tests were undoubtedly an essential precursor to the successful start of LHC beam commissioning. This paper provides an outline of preparation for the tests, the machine configuration and summarizes the measurements made and individual system performance
    • …
    corecore