Sporadic absorption tomography using a conical shell X-ray beam
We demonstrate tomography by measuring a sporadic sequence of ring shaped projections collected during a translational scan. We show that projections using 10% sampling may be used to construct optical sections with peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) of the order of 40 dB and 0.9, respectively. This relatively small degradation in image fidelity was achieved for a 90% potential reduction in X-ray dose coupled with a reduction in scan time. Our approach is scalable in both X-ray energy and inspection volume. A driver for our method is to complement previously reported conical shell beam techniques concerning the measurement of diffracted flux for structural analysis. This work is of great relevance to time critical analytical scanning applications in security screening, process control and diagnostic imaging
Recommended from our members
Confocal energy-dispersive X-ray diffraction tomography employing a conical shell beam
We introduce a new high-energy X-ray diffraction tomography technique for volumetric materials characterization. In this method, a conical shell beam is raster scanned through the samples. A central aperture optically couples the diffracted flux from the samples onto a pixelated energy-resolving detector. Snapshot measurements taken during the scan enable the construction of depth-resolved dark-field section images. The calculation of d-spacing values enables the mapping of material phase in a volumetric image. We demonstrate our technique using five ~15 mm thick, axially separated samples placed within a polymer tray of the type used routinely in airport security stations. Our method has broad analytical utility due to scalability in both scan size and X-ray energy. Additional application areas include medical diagnostics, materials science, and process control
X-ray absorption tomography employing a conical shell beam
We demonstrate depth-resolved absorption imaging by scanning an object through a conical shell of X-rays. We measure ring shaped projections and apply tomosynthesis to extract optical sections at different axial focal plane positions. Three-dimensional objects have been imaged to validate our theoretical treatment. The novel principle of our method is scalable with respect to both scan size and X-ray energy. A driver for this work is to
complement previously reported methods concerning the measurement of diffracted X-rays for structural analysis. The prospect of employing conical shell beams to combine both absorption and diffraction modalities would provide enhanced analytical utility and has many potential applications in security screening, process control and diagnostic imaging
Combined X-ray diffraction and absorption tomography using a conical shell beam
We combine diffraction and absorption tomography by raster scanning samples through a hollow cone of pseudo monochromatic X-rays with a mean energy of 58.4 keV. A single image intensifier takes 90x90 (x,y) snapshots during the scan. We demonstrate a proof-of-principle of our technique using a heterogeneous three-dimensional (x,y,z) phantom (90x90x170 mm3) comprised of different material phases, i.e., copper and sodium chlorate. Each snapshot enables the simultaneous measurement of absorption contrast and diffracted flux. The axial resolution was ~1 mm along the (x,y) orthogonal scan directions and ~7 mm along the z-axis. The tomosynthesis of diffracted flux measurements enable the calculation of d-spacing values with ~0.1 Ã… full width at half maximum (FWHM) at ~2 Ã…. Thus the identified materials may be color-coded in the absorption optical sections. Characterization of specific material phases is of particular interest in security screening for the identification of narcotics and a wide range of homemade explosives concealed within complex "everyday objects." Other potential application areas include process control and biological imaging
Recommended from our members
Conical shell X-ray beam tomosynthesis and micro-computed tomography for microarchitectural characterisation
Bone quality is commonly used to diagnose bone diseases such as osteoporosis, with many studies focusing on microarchitecture for fracture prediction. In this study a bovine distal femur was imaged using both micro-computed tomography (µCT) and tomosynthesis using focal construct geometry (FCG) for comparison of microarchitectural parameters. Six regions of interest (ROIs) were compared between the two imaging modalities, with both global and adaptive methods used to binarize the images. FCG images were downsampled to the same pixel size as the µCT images. Bone morphometrics were determined using BoneJ, for each imaging modality, binarization technique and ROI. Bone area/total area was found to have few significant differences between FCG and µCT (p < 0.05 for two of six ROIs). Fractal Dimension had only one significant difference (p < 0.05 for one of six ROIs) between µCT and downsampled FCG (where pixel size was equalized). Trabecular thickness and trabecular spacing were observed to follow trends as observed for the corresponding µCT images, although many absolute values were significantly different (p < 0.05 for between one and six ROIs depending on image types used). This study demonstrates the utility of tomosynthesis for measurement of microarchitectural morphometrics
Recommended from our members
Sparse interleaved sampling for high resolution focal construct geometry X-ray tomography
We demonstrate interleaved sampling by multiplexing conical subshells within the tomosynthesis and raster scanning a phantom through a 150 kV shell X-ray beam. Each view comprises pixels sampled on a regular 1 mm grid, which is then upscaled by padding with null pixels before tomosynthesis. We show that upscaled views comprising 1% sample pixels and 99% null pixels increase the contrast transfer function (CTF) computed from constructed optical sections from approximately 0.6 line pairs/mm to 3 line pairs/mm. The driver of our method is to complement work concerning the application of conical shell beams to the measurement of diffracted photons for materials identification. Our approach is relevant to time-critical, and dose-sensitive analytical scanning applications in security screening, process control and medical imaging
Visualization 1: X-ray absorption tomography employing a conical shell beam
X-ray Movie Frame Originally published in Optics Express on 12 December 2016 (oe-24-25-29048
Visualization 2: X-ray absorption tomography employing a conical shell beam
X-ray Movie Core Originally published in Optics Express on 12 December 2016 (oe-24-25-29048