1,936 research outputs found

    Performance of internal Covariance Estimators for Cosmic Shear Correlation Functions

    Get PDF
    Data re-sampling methods such as the delete-one jackknife are a common tool for estimating the covariance of large scale structure probes. In this paper we investigate the concepts of internal covariance estimation in the context of cosmic shear two-point statistics. We demonstrate how to use log-normal simulations of the convergence field and the corresponding shear field to carry out realistic tests of internal covariance estimators and find that most estimators such as jackknife or sub-sample covariance can reach a satisfactory compromise between bias and variance of the estimated covariance. In a forecast for the complete, 5-year DES survey we show that internally estimated covariance matrices can provide a large fraction of the true uncertainties on cosmological parameters in a 2D cosmic shear analysis. The volume inside contours of constant likelihood in the Ωm\Omega_m-σ8\sigma_8 plane as measured with internally estimated covariance matrices is on average 85%\gtrsim 85\% of the volume derived from the true covariance matrix. The uncertainty on the parameter combination Σ8σ8Ωm0.5\Sigma_8 \sim \sigma_8 \Omega_m^{0.5} derived from internally estimated covariances is 90%\sim 90\% of the true uncertainty.Comment: submitted to mnra

    Simultaneous dual-element analyses of refractory metals in naturally occurring matrices using resonance ionization of sputtered atoms

    Get PDF
    The combination of secondary neutral mass spectrometry (SNMS) and resonance ionization spectroscopy (RIS) has been shown to be a powerful tool for the detection of low levels of elemental impurities in solids. Drawbacks of the technique have been the laser-repetition-rate-limited, low duty cycle of the analysis and the fact that RIS schemes are limited to determinations of a single element. These problems have been addressed as part of an ongoing program to explore the usefulness of RIS/SNMS instruments for the analysis of naturally occurring samples. Efficient two-color, two-photon (1+1) resonance ionization schemes were identified for Mo and for four platinum-group elements (Ru, Os, Ir, and Re). Careful selection of the ionization schemes allowed Mo or Ru to be measured simultaneously with Re, Os, or Ir, using two tunable dye lasers and an XeCl excimer laser. Resonance frequencies could be switched easily under computer control, so that all five elements can be rapidly analyzed. In situ measurements of these elements in metal grains from five meteorites were conducted. From the analyses, estimates of the precision and the detection limit of the instrument were made. The trade-off between lower detection limits and rapid multielement RIS analyses is discussed

    Not all surveillance data are created equal—A multi‐method dynamic occupancy approach to determine rabies elimination from wildlife

    Get PDF
    1. A necessary component of elimination programmes for wildlife disease is effective surveillance. The ability to distinguish between disease freedom and non‐detection can mean the difference between a successful elimination campaign and new epizootics. Understanding the contribution of different surveillance methods helps to optimize and better allocate effort and develop more effective surveillance programmes. 2. We evaluated the probability of rabies virus elimination (disease freedom) in an enzootic area with active management using dynamic occupancy modelling of 10 years of raccoon rabies virus (RABV) surveillance data (2006–2015) collected from three states in the eastern United States. We estimated detection probability of RABV cases for each surveillance method (e.g. strange acting reports, roadkill, surveillance‐trapped animals, nuisance animals and public health samples) used by the USDA National Rabies Management Program. 3. Strange acting, found dead and public health animals were the most likely to detect RABV when it was present, and generally detectability was higher in fall– winter compared to spring–summer. Found dead animals in fall–winter had the highest detection at 0.33 (95% CI: 0.20, 0.48). Nuisance animals had the lowest detection probabilities (~0.02). 4. Areas with oral rabies vaccination (ORV) management had reduced occurrence probability compared to enzootic areas without ORV management. RABV occurrence was positively associated with deciduous and mixed forests and medium to high developed areas, which are also areas with higher raccoon (Procyon lotor) densities. By combining occupancy and detection estimates we can create a probability of elimination surface that can be updated seasonally to provide guidance on areas managed for wildlife disease. 5. Synthesis and applications. Wildlife disease surveillance is often comprised of a combination of targeted and convenience‐based methods. Using a multi‐method analytical approach allows us to compare the relative strengths of these methods, providing guidance on resource allocation for surveillance actions. Applying this multi‐method approach in conjunction with dynamic occupancy analyses better informs management decisions by understanding ecological drivers of disease occurrence

    COMPARISON of DIVER-OPERATED UNDERWATER PHOTOGRAMMETRIC SYSTEMS for CORAL REEF MONITORING

    Get PDF
    Underwater photogrammetry is a well-established technique for measuring and modelling the subaquatic environment in fields ranging from archaeology to marine ecology. While for simple tasks the acquisition and processing of images have become straightforward, applications requiring relative accuracy better then 1:1000 are still considered challenging. This study focuses on the metric evaluation of different off-the-shelf camera systems for making high resolution and high accuracy measurements of coral reefs monitoring through time, where the variations to be measured are in the range of a few centimeters per year. High quality and low-cost systems (reflex and mirrorless vs action cameras, i.e. GoPro) with multiple lenses (prime and zoom), different fields of views (from fisheye to moderate wide angle), pressure housing materials and lens ports (dome and flat) are compared. Tests are repeated at different camera to object distances to investigate distance dependent induced errors and assess the accuracy of the photogrammetrically derived models. An extensive statistical analysis of the different systems is performed and comparisons against reference control point measured through a high precision underwater geodetic network are reported

    A fast empirical method for galaxy shape measurements in weak lensing surveys

    Full text link
    We describe a simple and fast method to correct ellipticity measurements of galaxies from the distortion by the instrumental and atmospheric point spread function (PSF), in view of weak lensing shear measurements. The method performs a classification of galaxies and associated PSFs according to measured shape parameters, and corrects the measured galaxy ellipticites by querying a large lookup table (LUT), built by supervised learning. We have applied this new method to the GREAT10 image analysis challenge, and present in this paper a refined solution that obtains the competitive quality factor of Q = 104, without any shear power spectrum denoising or training. Of particular interest is the efficiency of the method, with a processing time below 3 ms per galaxy on an ordinary CPU.Comment: 8 pages, 6 figures. Metric values updated according to the final GREAT10 analysis software (Kitching et al. 2012, MNRAS 423, 3163-3208), no qualitative changes. Associated code available at http://lastro.epfl.ch/megalu

    An assessment of pulse transit time for detecting heavy blood loss during surgical operation

    Get PDF
    Copyright @ Wang et al.; Licensee Bentham Open. This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.The main contribution of this paper is the use of non-invasive measurements such as electrocardiogram (ECG) and photoplethysmographic (PPG) pulse oximetry waveforms to develop a new physiological signal analysis technique for detecting blood loss during surgical operation. Urological surgery cases were considered as the control group due to its generality, and cardiac surgery as experimental group since it involves blood loss and water supply. Results show that the control group has the tendency of a reduction of the pulse transient time (PTT), and this indicates an increment in the blood flow velocity changes from slow to fast. While for the experimental group, the PTT indicates high values during blood loss, and low values during water supply. Statistical analysis shows considerable differences (i.e., P <0.05) between both groups leading to the conclusion that PTT could be a good indicator for monitoring patients' blood loss during a surgical operation.The National Science Council (NSC) of Taiwan and the Centre for Dynamical Biomarkers and Translational Medicine, National Central University, Taiwan
    corecore