1,022 research outputs found
XAX: a multi-ton, multi-target detection system for dark matter, double beta decay and pp solar neutrinos
A multi-target detection system XAX, comprising concentric 10 ton targets of
136Xe and 129/131Xe, together with a geometrically similar or larger target of
liquid Ar, is described. Each is configured as a two-phase
scintillation/ionization TPC detector, enhanced by a full 4pi array of
ultra-low radioactivity Quartz Photon Intensifying Detectors (QUPIDs) replacing
the conventional photomultipliers for detection of scintillation light. It is
shown that background levels in XAX can be reduced to the level required for
dark matter particle (WIMP) mass measurement at a 10^-10 pb WIMP-nucleon cross
section, with single-event sensitivity below 10^-11 pb. The use of multiple
target elements allows for confirmation of the A^2 dependence of a coherent
cross section, and the different Xe isotopes provide information on the
spin-dependence of the dark matter interaction. The event rates observed by Xe
and Ar would modulate annually with opposite phases from each other for WIMP
mass >~100 GeV/c^2. The large target mass of 136Xe and high degree of
background reduction allow neutrinoless double beta decay to be observed with
lifetimes of 10^27-10^28 years, corresponding to the Majorana neutrino mass
range 0.01-0.1 eV, the most likely range from observed neutrino mass
differences. The use of a 136Xe-depleted 129/131Xe target will also allow
measurement of the pp solar neutrino spectrum to a precision of 1-2%.Comment: 16 pages with 17 figure
Multifocal Fluorescence Microscope for Fast Optical Recordings of Neuronal Action Potentials
AbstractIn recent years, optical sensors for tracking neural activity have been developed and offer great utility. However, developing microscopy techniques that have several kHz bandwidth necessary to reliably capture optically reported action potentials (APs) at multiple locations in parallel remains a significant challenge. To our knowledge, we describe a novel microscope optimized to measure spatially distributed optical signals with submillisecond and near diffraction-limit resolution. Our design uses a spatial light modulator to generate patterned illumination to simultaneously excite multiple user-defined targets. A galvanometer driven mirror in the emission path streaks the fluorescence emanating from each excitation point during the camera exposure, using unused camera pixels to capture time varying fluorescence at rates that are âŒ1000 times faster than the cameraâs native frame rate. We demonstrate that this approach is capable of recording Ca2+ transients resulting from APs in neurons labeled with the Ca2+ sensor Oregon Green Bapta-1 (OGB-1), and can localize the timing of these events with millisecond resolution. Furthermore, optically reported APs can be detected with the voltage sensitive dye DiO-DPA in multiple locations within a neuron with a signal/noise ratio up to âŒ40, resolving delays in arrival time along dendrites. Thus, the microscope provides a powerful tool for photometric measurements of dynamics requiring submillisecond sampling at multiple locations
Lepton Flavor Violation in the Two Higgs Doublet Model type III
We consider the Two Higgs Doublet Model (2HDM) of type III which leads to
Flavour Changing Neutral Currents (FCNC) at tree level in the leptonic sector.
In the framework of this model we can have, in principle, two situations: the
case (a) when both doublets acquire a vacuum expectation value different from
zero and the case (b) when only one of them is not zero. In addition, we show
that we can make two types of rotations for the flavor mixing matrices which
generates four types of lagrangians, with the rotation of type I we recover the
case (b) from the case (a) in the limit , and with the
rotation of type II we obtain the case (b) from (a) in the limit Moreover, two of the four possible lagrangians correspond to the models
of types I and II plus Flavor Changing (FC) interactions. The analitical
expressions of the partial lepton number violating widths and are derived for the cases (a) and (b) and both
types of rotations.In all cases these widths go asymptotically to zero in
the decoupling limit for all Higgses. We present from our analysis upper bounds
for the flavour changing transition and we show that such bounds
are sensitive to the VEV structure and the type of rotation utilized.Comment: 7 pages RevTeX4, 4 figures postscript, new section added and some new
reference
First Dark Matter Results from the XENON100 Experiment
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran
Sasso in Italy, is designed to search for dark matter WIMPs scattering off 62
kg of liquid xenon in an ultra-low background dual-phase time projection
chamber. In this letter, we present first dark matter results from the analysis
of 11.17 live days of non-blind data, acquired in October and November 2009. In
the selected fiducial target of 40 kg, and within the pre-defined signal
region, we observe no events and hence exclude spin-independent WIMP-nucleon
elastic scattering cross-sections above 3.4 x 10^-44 cm^2 for 55 GeV/c^2 WIMPs
at 90% confidence level. Below 20 GeV/c^2, this result constrains the
interpretation of the CoGeNT and DAMA signals as being due to spin-independent,
elastic, light mass WIMP interactions.Comment: 5 pages, 5 figures. Matches published versio
Rare Kaon Decays
The current status of rare kaon decay experiments is reviewed. New limits in
the search for Lepton Flavor Violation are discussed, as are new measurements
of the CKM matrix.Comment: 8 pages, 3 figures, LaTeX, presented at the 3rd International
Conference on B Phyiscs and CP Violation, Taipei December 3-7, 199
Dark Matter Results from 100 Live Days of XENON100 Data
We present results from the direct search for dark matter with the XENON100
detector, installed underground at the Laboratori Nazionali del Gran Sasso of
INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg
liquid xenon target. Interaction vertex reconstruction in three dimensions with
millimeter precision allows to select only the innermost 48 kg as ultra-low
background fiducial target. In 100.9 live days of data, acquired between
January and June 2010, no evidence for dark matter is found. Three candidate
events were observed in a pre-defined signal region with an expected background
of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter
interactions today, excluding spin-independent elastic WIMP-nucleon scattering
cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90%
confidence level.Comment: 5 pages, 5 figures; matches accepted versio
Implications on Inelastic Dark Matter from 100 Live Days of XENON100 Data
The XENON100 experiment has recently completed a dark matter run with 100.9
live-days of data, taken from January to June 2010. Events in a 48kg fiducial
volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A
total of three events have been found in the predefined signal region,
compatible with the background prediction of (1.8 \pm 0.6) events. Based on
this analysis we present limits on the WIMP-nucleon cross section for inelastic
dark matter. With the present data we are able to rule out the explanation for
the observed DAMA/LIBRA modulation as being due to inelastic dark matter
scattering off iodine at a 90% confidence level.Comment: 3 pages, 3 figure
Beam test results for the FiberGLAST instrument
The FiberGLAST scintillating fiber telescope is a large-area instrument concept for NASA\u27s GLAST program. The detector is designed for high-energy gamma-ray astronomy, and uses plastic scintillating fibers to combine a photon pair tracking telescope and a calorimeter into a single instrument. A small prototype detector has been tested with high energy photons at the Thomas Jefferson National Accelerator Facility. We report on the result of this beam test, including scintillating fiber performance, photon track reconstruction, angular resolution, and detector efficiency
Comment on "On the subtleties of searching for dark matter with liquid xenon detectors"
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that
XENON100's upper limits on spin-independent WIMP-nucleon cross sections for
WIMP masses below 10 GeV "may be understated by one order of magnitude or
more". Having performed a similar, though more detailed analysis prior to the
submission of our new result (arXiv:1207.5988), we do not confirm these
findings. We point out the rationale for not considering the described effect
in our final analysis and list several potential problems with his study.Comment: 3 pages, no figure
Global anisotropy of arrival directions of ultra-high-energy cosmic rays: capabilities of space-based detectors
Planned space-based ultra-high-energy cosmic-ray detectors (TUS, JEM-EUSO and
S-EUSO) are best suited for searches of global anisotropies in the distribution
of arrival directions of cosmic-ray particles because they will be able to
observe the full sky with a single instrument. We calculate quantitatively the
strength of anisotropies associated with two models of the origin of the
highest-energy particles: the extragalactic model (sources follow the
distribution of galaxies in the Universe) and the superheavy dark-matter model
(sources follow the distribution of dark matter in the Galactic halo). Based on
the expected exposure of the experiments, we estimate the optimal strategy for
efficient search of these effects.Comment: 19 pages, 7 figures, iopart style. v.2: discussion of the effect of
the cosmic magnetic fields added; other minor changes. Simulated UHECR
skymaps available at http://livni.inr.ac.ru/UHECRskymaps
- âŠ