414 research outputs found

    Improving activity recognition using a wearable barometric pressure sensor in mobility-impaired stroke patients.

    Get PDF
    © 2015 Massé et al.Background: Stroke survivors often suffer from mobility deficits. Current clinical evaluation methods, including questionnaires and motor function tests, cannot provide an objective measure of the patients mobility in daily life. Physical activity performance in daily-life can be assessed using unobtrusive monitoring, for example with a single sensor module fixed on the trunk. Existing approaches based on inertial sensors have limited performance, particularly in detecting transitions between different activities and postures, due to the inherent inter-patient variability of kinematic patterns. To overcome these limitations, one possibility is to use additional information from a barometric pressure (BP) sensor. Methods: Our study aims at integrating BP and inertial sensor data into an activity classifier in order to improve the activity (sitting, standing, walking, lying) recognition and the corresponding body elevation (during climbing stairs or when taking an elevator). Taking into account the trunk elevation changes during postural transitions (sit-to-stand, stand-to-sit), we devised an event-driven activity classifier based on fuzzy-logic. Data were acquired from 12 stroke patients with impaired mobility, using a trunk-worn inertial and BP sensor. Events, including walking and lying periods and potential postural transitions, were first extracted. These events were then fed into a double-stage hierarchical Fuzzy Inference System (H-FIS). The first stage processed the events to infer activities and the second stage improved activity recognition by applying behavioral constraints. Finally, the body elevation was estimated using a pattern-enhancing algorithm applied on BP. The patients were videotaped for reference. The performance of the algorithm was estimated using the Correct Classification Rate (CCR) and F-score. The BP-based classification approach was benchmarked against a previously-published fuzzy-logic classifier (FIS-IMU) and a conventional epoch-based classifier (EPOCH). Results: The algorithm performance for posture/activity detection, in terms of CCR was 90.4 %, with 3.3 % and 5.6 % improvements against FIS-IMU and EPOCH, respectively. The proposed classifier essentially benefits from a better recognition of standing activity (70.3 % versus 61.5 % [FIS-IMU] and 42.5 % [EPOCH]) with 98.2 % CCR for body elevation estimation. Conclusion: The monitoring and recognition of daily activities in mobility-impaired stoke patients can be significantly improved using a trunk-fixed sensor that integrates BP, inertial sensors, and an event-based activity classifier

    ANALYSIS OF STABLE FLIGHT IN SKI JUMPING BASED ON PARAMETERS MEASURED WITH A WEARABLE SYSTEM

    Get PDF
    Biomechanics analysis of the ski jump is highly required. Some parameters and their interrelations have been reported in previous research studies limited to few athletes. The generalization of these parameters to athletes of various levels and under training conditions should be assessed, since they have the potential to be used for daily evaluation. This study proposed a new 3D approach based on inertial sensors to evaluate relevant kinematic and aerodynamic parameters of stable flight phase. The proposed wearable system can easily be used for daily training. Aerodynamic forces and body segments 3D angles were extracted during the stable flight phase of 86 jumps. Then, their correlations with respect to distance as well as their interrelations were analyzed. Their combination expressed 55% of the total distance variance

    A new ambulatory system for comparative evaluation of the three-dimensional knee kinematics, applied to anterior cruciate ligament injuries

    Get PDF
    The aim of this study was to develop an ambulatory system for the three-dimensional (3D) knee kinematics evaluation, which can be used outside a laboratory during long-term monitoring. In order to show the efficacy of this ambulatory system, knee function was analysed using this system, after an anterior cruciate ligament (ACL) lesion, and after reconstructive surgery. The proposed system was composed of two 3D gyroscopes, fixed on the shank and on the thigh, and a portable data logger for signal recording. The measured parameters were the 3D mean range of motion (ROM) and the healthy knee was used as control. The precision of this system was first assessed using an ultrasound reference system. The repeatability was also estimated. A clinical study was then performed on five unilateral ACL-deficient men (range: 19-36years) prior to, and a year after the surgery. The patients were evaluated with the IKDC score and the kinematics measurements were carried out on a 30m walking trial. The precision in comparison with the reference system was 4.4°, 2.7° and 4.2° for flexion-extension, internal-external rotation, and abduction-adduction, respectively. The repeatability of the results for the three directions was 0.8°, 0.7° and 1.8°. The averaged ROM of the five patients' healthy knee were 70.1° [standard deviation (SD) 5.8°], 24.0° (SD 3.0°) and 12.0° (SD 6.3°) for flexion-extension, internal-external rotation and abduction-adduction before surgery, and 76.5° (SD 4.1°), 21.7° (SD 4.9°) and 10.2° (SD 4.6°) 1year following the reconstruction. The results for the pathologic knee were 64.5° (SD 6.9°), 20.6° (SD 4.0°) and 19.7° (8.2°) during the first evaluation, and 72.3° (SD 2.4°), 25.8° (SD 6.4°) and 12.4° (SD 2.3°) during the second one. The performance of the system enabled us to detect knee function modifications in the sagittal and transverse plane. Prior to the reconstruction, the ROM of the injured knee was lower in flexion-extension and internal-external rotation in comparison with the controlateral knee. One year after the surgery, four patients were classified normal (A) and one almost normal (B), according to the IKDC score, and changes in the kinematics of the five patients remained: lower flexion-extension ROM and higher internal-external rotation ROM in comparison with the controlateral knee. The 3D kinematics was changed after an ACL lesion and remained altered one year after the surger

    The relationship between video display terminals (VDTs) usage and dermatologic manifestations : a cross sectional study

    Get PDF
    BACKGROUND: Recently, it has been observed that Video Display Terminals (VDTs) usage for long periods can cause some dermatological manifestations on the face. An analytical cross-sectional study was designed in order to determine this relationship. METHODS: In this study, 600 office workers were chosen randomly from an organization in Tehran (Iran). The subjects were then divided into two groups based on their exposure to VDTs. 306 workers were considered exposure negative (non VDT user) who worked less than 7 hours a week with VDTs. The remainders 294 were exposure-positive, who worked 7 hours or more with VDTs. The frequency of dermatologic manifestations was compared in these two groups. RESULTS: In the exposure-positive and exposure-negative groups, the frequency of these dermatologic manifestations were 27 and 5 respectively. After statistical analysis, a P.value of < 0.05 was obtained indicating a statistically significant difference between these two groups for dermatological manifestations. CONCLUSION: According to our study, there is a relationship between dermatologic manifestations on the face and exposure to VDTs

    Cardiac chronotropic hypo-responsiveness and atrial fibrosis in rats chronically treated with lithium

    Get PDF
    Lithium is a widely used mood-stabilizing agent; however, it causes a variety of cardiovascular side effects including sinus node dysfunction. In this study we explored the potential adverse effects of lithium on cardiac chronotropic responsiveness, atrial tissue histology and gene expression in rats that were chronically treated with therapeutic doses of lithium. Male Wistar albino rats were given lithium chloride (2.5 g/kg) orally for 2 or 3 months. Following treatment, the atria were isolated and spontaneously beating rate and chronotropic responsiveness to β-adrenergic stimulation was evaluated in an organ bath. Development of cardiac fibrosis was examined by histological methods. The expression of atrial Col1a1 (collagen I, alpha 1) and β-arrestin2 was also assessed using quantitative RT-PCR. Treatment with lithium induced a significant hypo-responsiveness to adrenergic stimulation (P < 0.001) and caused fibrosis in the atrial tissue of treated rats. In addition, the expression of atrial Col1a1 mRNA was significantly increased in atrial tissues of lithium-treated animals, while β-arrestin2 mRNA expression did not show a significant difference compared with control animals. Altogether, these findings indicate that cardiac chronotropic hypo responsiveness and associated cardiac fibrosis are side effects of chronic lithium treatment. Moreover, it seems that lithium treatment does not influence β-arrestin2 mRNA expressio

    Distal Versus Conventional Radial Access for Coronary Angiography and Intervention The DISCO RADIAL Trial

    Get PDF
    BACKGROUND Currently, transradial access (TRA) is the recommended access for coronary procedures because of increased safety, with radial artery occlusion (RAO) being its most frequent complication, which will increasingly affect patients undergoing multiple procedures during their lifetimes. Recently, distal radial access (DRA) has emerged as a promising alternative access to minimize RAO risk. A large-scale, international, randomized trial comparing RAO with TRA and DRA is lacking. OBJECTIVES The aim of this study was to assess the superiority of DRA compared with conventional TRA with respect to forearm RAO. METHODS DISCO RADIAL (Distal vs Conventional Radial Access) was an international, multicenter, randomized controlled trial in which patients with indications for percutaneous coronary procedure using a 6-F Slender sheath were randomized to DRA or TRA with systematic implementation of best practices to reduce RAO. The primary endpoint was the incidence of forearm RAO assessed by vascular ultrasound at discharge. Secondary endpoints include crossover, hemostasis time, and access site-related complications. RESULTS Overall, 657 patients underwent TRA, and 650 patients underwent DRA. Forearm RAO did not differ between groups (0.91% vs 0.31%; P = 0.29). Patent hemostasis was achieved in 94.4% of TRA patients. Crossover rates were higher with DRA (3.5% vs 7.4%; P = 0.002), and median hemostasis time was shorter (180 vs 153 minutes; P < 0.001). Radial artery spasm occurred more with DRA (2.7% vs 5.4%; P = 0.015). Overall bleeding events and vascular complications did not differ between groups. CONCLUSIONS With the implementation of a rigorous hemostasis protocol, DRA and TRA have equally low RAO rates. DRA is associated with a higher crossover rate but a shorter hemostasis time. (C) 2022 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation

    Cognitive loading affects motor awareness and movement kinematics but not locomotor trajectories during goal-directed walking in a virtual reality environment.

    Get PDF
    The primary purpose of this study was to investigate the effects of cognitive loading on movement kinematics and trajectory formation during goal-directed walking in a virtual reality (VR) environment. The secondary objective was to measure how participants corrected their trajectories for perturbed feedback and how participants' awareness of such perturbations changed under cognitive loading. We asked 14 healthy young adults to walk towards four different target locations in a VR environment while their movements were tracked and played back in real-time on a large projection screen. In 75% of all trials we introduced angular deviations of ±5° to ±30° between the veridical walking trajectory and the visual feedback. Participants performed a second experimental block under cognitive load (serial-7 subtraction, counter-balanced across participants). We measured walking kinematics (joint-angles, velocity profiles) and motor performance (end-point-compensation, trajectory-deviations). Motor awareness was determined by asking participants to rate the veracity of the feedback after every trial. In-line with previous findings in natural settings, participants displayed stereotypical walking trajectories in a VR environment. Our results extend these findings as they demonstrate that taxing cognitive resources did not affect trajectory formation and deviations although it interfered with the participants' movement kinematics, in particular walking velocity. Additionally, we report that motor awareness was selectively impaired by the secondary task in trials with high perceptual uncertainty. Compared with data on eye and arm movements our findings lend support to the hypothesis that the central nervous system (CNS) uses common mechanisms to govern goal-directed movements, including locomotion. We discuss our results with respect to the use of VR methods in gait control and rehabilitation

    A robust walking detection algorithm using a single foot-worn inertial sensor: validation in real-life settings

    Get PDF
    Walking activity and gait parameters are considered among the most relevant mobility-related parameters. Currently, gait assessments have been mainly analyzed in laboratory or hospital settings, which only partially reflect usual performance (i.e., real world behavior). In this study, we aim to validate a robust walking detection algorithm using a single foot-worn inertial measurement unit (IMU) in real-life settings. We used a challenging dataset including 18 individuals performing free-living activities. A multi-sensor wearable system including pressure insoles, multiple IMUs, and infrared distance sensors (INDIP) was used as reference. Accurate walking detection was obtained, with sensitivity and specificity of 98 and 91% respectively. As robust walking detection is needed for ambulatory monitoring to complete the processing pipeline from raw recorded data to walking/mobility outcomes, a validated algorithm would pave the way for assessing patient performance and gait quality in real-world conditions

    Razine antinuklearnoga antitijela i reumatoidnoga faktora u radnika izloženih silicijevu dioksidu

    Get PDF
    A lot of workers in industries such as foundry, stonecutting, and sandblasting are exposed to higher than permissible levels of crystalline silica. Various alterations in humoral immune function have been reported in silicosis patients and workers exposed to silica dust. The aim of this study was to measure antinuclear antibody (ANA) and rheumatoid factor (RF) levels in foundry workers exposed to silica and to compare them with a control group without such exposure. ANA and RF were measured in 78 exposed and 73 non-exposed workers, and standard statistical methods were used to compare them. The two groups did not significantly differ in age and smoking. Mean work duration of the exposed and non-exposed workers was (14.9±4.72) years and (12.41±6.3) years, respectively. Ten exposed workers had silicosis. ANA was negative in all workers in either group. Its mean titer did not differ significantly between the exposed and control workers [(0.39±0.15) IU mL-1 vs. (0.36±0.17) IU mL-1, respectively]. RF was positive in two workers of each group. Other studies have reported an increase in ANA and RF associated with exposure to silica dust and silicosis. In contrast, our study suggests that exposure to silica dust does not increase the level of ANA and RF in exposed workers.Mnogi su radnici izloženi kristalnomu silicijevu dioksidu u razinama iznad dopuštenih. U oboljelih od silikoze i radnika izloženih prašinama koje sadržavaju silicijev dioksid zamijećen je niz oštećenja humoralne obrane. Budući da su radnici u ljevaonicama izloženi visokim razinama kristalnoga silicijeva dioksida, u njih bismo očekivali ovakve humoralne poremećaje. Cilj je ovog ispitivanja bio izmjeriti i usporediti razine antinuklearnih protutijela (ANA) i reumatoidnoga faktora (RF) u krvi radnika u ljevaonici izloženih silicijevu dioksidu i neizložene kontrolne skupine. ANA i RF izmjereni su u 78 izloženih radnika i 73 neizložena radnika te su uspoređeni s pomoću standardnih statističkih metoda. Dvije se skupine nisu bitno razlikovale u broju pušača i u dobi. Prosječna duljina radnog vijeka izloženih radnika bila je (14,9±4,72) godine, a neizloženih (12,41±6,3) godine. Deset izloženih radnika imalo je silikozu. Nalazi ANA bili su negativni u obje skupine radnika. Srednja vrijednost titra ANA iznosila je (0,39±0,15) IU mL-1 u izloženih ispitanika, a (0,36±0,17) IU mL-1 u kontrola, što je statistički zanemariva razlika. Nalaz RF-a bio je pozitivan u dva izložena te dva kontrolna radnika. Naše ispitivanje upućuje na to da prašine silicijeva dioksida ne uzrokuju porast razina ANA i RF-a u izloženih radnika
    corecore