92 research outputs found

    Automated Quality Control for Sensor Based Symptom Measurement Performed Outside the Lab

    Get PDF
    The use of wearable sensing technology for objective, non-invasive and remote clinimetric testing of symptoms has considerable potential. However, the accuracy achievable with such technology is highly reliant on separating the useful from irrelevant sensor data. Monitoring patient symptoms using digital sensors outside of controlled, clinical lab settings creates a variety of practical challenges, such as recording unexpected user behaviors. These behaviors often violate the assumptions of clinimetric testing protocols, where these protocols are designed to probe for specific symptoms. Such violations are frequent outside the lab and affect the accuracy of the subsequent data analysis and scientific conclusions. To address these problems, we report on a unified algorithmic framework for automated sensor data quality control, which can identify those parts of the sensor data that are sufficiently reliable for further analysis. Combining both parametric and nonparametric signal processing and machine learning techniques, we demonstrate that across 100 subjects and 300 clinimetric tests from three different types of behavioral clinimetric protocols, the system shows an average segmentation accuracy of around 90%. By extracting reliable sensor data, it is possible to strip the data of confounding factors in the environment that may threaten reproducibility and replicability

    TSDF: A simple yet comprehensive, unified data storage and exchange format standard for digital biosensor data in health applications

    Full text link
    Digital sensors are increasingly being used to monitor the change over time of physiological processes in biological health and disease, often using wearable devices. This generates very large amounts of digital sensor data, for which, a consensus on a common storage, exchange and archival data format standard, has yet to be reached. To address this gap, we propose Time Series Data Format (TSDF): a unified, standardized format for storing all types of physiological sensor data, across diverse disease areas. We pose a series of format design criteria and review in detail current storage and exchange formats. When judged against these criteria, we find these current formats lacking, and propose a very simple, intuitive standard for both numerical sensor data and metadata, based on raw binary data and JSON-format text files, for sensor measurements/timestamps and metadata, respectively. By focusing on the common characteristics of diverse biosensor data, we define a set of necessary and sufficient metadata fields for storing, processing, exchanging, archiving and reliably interpreting, multi-channel biological time series data. Our aim is for this standardized format to increase the interpretability and exchangeability of data, thereby contributing to scientific reproducibility in studies where digital biosensor data forms a key evidence base

    Probabilistic modelling of gait for robust passive monitoring in daily life

    Get PDF
    Passive monitoring in daily life may provide valuable insights into a person's health throughout the day. Wearable sensor devices play a key role in enabling such monitoring in a non-obtrusive fashion. However, sensor data collected in daily life reflect multiple health and behavior-related factors together. This creates the need for a structured principled analysis to produce reliable and interpretable predictions that can be used to support clinical diagnosis and treatment. In this work we develop a principled modelling approach for free-living gait (walking) analysis. Gait is a promising target for non-obtrusive monitoring because it is common and indicative of many different movement disorders such as Parkinson's disease (PD), yet its analysis has largely been limited to experimentally controlled lab settings. To locate and characterize stationary gait segments in free-living using accelerometers, we present an unsupervised probabilistic framework designed to segment signals into differing gait and non-gait patterns. We evaluate the approach using a new video-referenced dataset including 25 PD patients with motor fluctuations and 25 age-matched controls, performing unscripted daily living activities in and around their own houses. Using this dataset, we demonstrate the framework's ability to detect gait and predict medication induced fluctuations in PD patients based on free-living gait. We show that our approach is robust to varying sensor locations, including the wrist, ankle, trouser pocket and lower back

    Usability and utility of a remote monitoring system to support physiotherapy for people with Parkinson's disease

    Get PDF
    BackgroundPhysiotherapy for persons with Parkinson's disease (PwPD) could benefit from objective and continuous tracking of physical activity and falls in daily life.ObjectivesWe designed a remote monitoring system for this purpose and describe the experiences of PwPD and physiotherapists who used the system in daily clinical practice.MethodsTwenty-one PwPD (15 men) wore a sensor necklace to passively record physical activity and falls for 6 weeks. They also used a smartphone app to self-report daily activities, (near-)falls and medication intake. They discussed those data with their PD-specialized physiotherapist (n = 9) during three regular treatment sessions. User experiences and aspects to be improved were gathered through interviews with PwPD and physiotherapists, resulting in system updates. The system was evaluated in a second pilot with 25 new PwPD (17 men) and eight physiotherapists.ResultsWe applied thematic analysis to the interview data resulting in two main themes: usability and utility. First, the usability of the system was rated positively, with the necklace being easy to use. However, some PwPD with limited digital literacy or cognitive impairments found the app unclear. Second, the perceived utility of the system varied among PwPD. While many PwPD were motivated to increase their activity level, others were not additionally motivated because they perceived their activity level as high. Physiotherapists appreciated the objective recording of physical activity at home and used the monitoring of falls to enlarge awareness of the importance of falls for PwPD. Based on the interview data of all participants, we drafted three user profiles for PwPD regarding the benefits of remote monitoring for physiotherapy: for profile 1, a monitoring system could act as a flagging dashboard to signal the need for renewed treatment; for profile 2, a monitoring system could be a motivational tool to maintain physical activity; for profile 3, a monitoring system could passively track physical activity and falls at home. Finally, for a subgroup of PwPD the burdens of monitoring will outweigh the benefits.ConclusionsOverall, both PwPD and physiotherapists underline the potential of a remote monitoring system to support physiotherapy by targeting physical activity and (near-)falls. Our findings emphasize the importance of personalization in remote monitoring technology, as illustrated by our user profiles

    Impact of motor fluctuations on real-life gait in Parkinson’s patients

    Get PDF
    Background people with PD (PWP) have an increased risk of becoming inactive. Wearable sensors can provide insights into daily physical activity and walking patterns. Research questions (1) is the severity of motor fluctuations associated with sensor-derived average daily walking quantity? (2) is the severity of motor fluctuations associated with the amount of change in sensor-derived walking quantity after levodopa intake? Methods 304 Dutch PWP from the Parkinson@Home study were included. At baseline, all participants received a clinical examination. During the follow-up period (median: 97 days; 25-Interquartile range-IQR: 91 days, 75-IQR: 188 days), participants used the Fox Wearable Companion app and streamed smartwatch accelerometer data to a cloud platform. The first research question was assessed by linear regression on the sensor-derived mean time spent walking/day with the severity of fluctuations (MDS-UPDRS item 4.4) as independent variable, controlled for age and MDS-UPDRS part-III score. The second research question was assessed by linear regression on the sensor-derived mean post-levodopa walking quantity, with the sensor-derived mean pre-levodopa walking quantity and severity of fluctuations as independent variables, controlled for mean time spent walking per day, age and MDS-UPDRS part-III score. Results PWP spent most time walking between 8am and 1pm, summing up to 72 ± 39 (mean ± standard deviation) minutes of walking/day. The severity of motor fluctuations did not influence the mean time spent walking (B = 2.4 ± 1.9, p = 0.20), but higher age (B = −1.3 ± 0.3, p = < 0.001) and greater severity of motor symptoms (B = −0.6 ± 0.2, p < 0.001) was associated with less time spent walking (F(3,216) = 14.6, p<.001, R2 =.17). The severity of fluctuations was not associated with the amount of change in time spent walking in relation to levodopa intake in any part of the day. Significance Analysis of sensor-derived gait quantity suggests that the severity of motor fluctuations is not associated with changes in real-life walking patterns in mildly to moderate affected PWP

    Real-Life Gait Performance as a Digital Biomarker for Motor Fluctuations: The Parkinson@Home Validation Study

    Get PDF
    Background: Wearable sensors have been used successfully to characterize bradykinetic gait in patients with Parkinson disease (PD), but most studies to date have been conducted in highly controlled laboratory environments. Objective: This paper aims to assess whether sensor-based analysis of real-life gait can be used to objectively and remotely monitor motor fluctuations in PD. Methods: The Parkinson@Home validation study provides a new reference data set for the development of digital biomarkers to monitor persons with PD in daily life. Specifically, a group of 25 patients with PD with motor fluctuations and 25 age-matched controls performed unscripted daily activities in and around their homes for at least one hour while being recorded on video. Patients with PD did this twice: once after overnight withdrawal of dopaminergic medication and again 1 hour after medication intake. Participants wore sensors on both wrists and ankles, on the lower back, and in the front pants pocket, capturing movement and contextual data. Gait segments of 25 seconds were extracted from accelerometer signals based on manual video annotations. The power spectral density of each segment and device was estimated using Welch’s method, from which the total power in the 0.5- to 10-Hz band, width of the dominant frequency, and cadence were derived. The ability to discriminate between before and after medication intake and between patients with PD and controls was evaluated using leave-one-subject-out nested cross-validation. Results: From 18 patients with PD (11 men; median age 65 years) and 24 controls (13 men; median age 68 years), ≥10 gait segments were available. Using logistic LASSO (least absolute shrinkage and selection operator) regression, we classified whether the unscripted gait segments occurred before or after medication intake, with mean area under the receiver operator curves (AUCs) varying between 0.70 (ankle of least affected side, 95% CI 0.60-0.81) and 0.82 (ankle of most affected side, 95% CI 0.72-0.92) across sensor locations. Combining all sensor locations did not significantly improve classification (AUC 0.84, 95% CI 0.75-0.93). Of all signal properties, the total power in the 0.5- to 10-Hz band was most responsive to dopaminergic medication. Discriminating between patients with PD and controls was generally more difficult (AUC of all sensor locations combined: 0.76, 95% CI 0.62-0.90). The video recordings revealed that the positioning of the hands during real-life gait had a substantial impact on the power spectral density of both the wrist and pants pocket sensor. Conclusions: We present a new video-referenced data set that includes unscripted activities in and around the participants’ homes. Using this data set, we show the feasibility of using sensor-based analysis of real-life gait to monitor motor fluctuations with a single sensor location. Future work may assess the value of contextual sensors to control for real-world confounders

    Long-term unsupervised mobility assessment in movement disorders

    Get PDF
    Mobile health technologies (wearable, portable, body-fixed sensors, or domestic-integrated devices) that quantify mobility in unsupervised, daily living environments are emerging as complementary clinical assessments. Data collected in these ecologically valid, patient-relevant settings can overcome limitations of conventional clinical assessments, as they capture fluctuating and rare events. These data could support clinical decision making and could also serve as outcomes in clinical trials. However, studies that directly compared assessments made in unsupervised and supervised (eg, in the laboratory or hospital) settings point to large disparities, even in the same parameters of mobility. These differences appear to be affected by psychological, physiological, cognitive, environmental, and technical factors, and by the types of mobilities and diagnoses assessed. To facilitate the successful adaptation of the unsupervised assessment of mobility into clinical practice and clinical trials, clinicians and researchers should consider these disparities and the multiple factors that contribute to them
    • …
    corecore