485 research outputs found

    RP-LC and HPTLC Methods for the Determination of Olmesartan Medoxomil and Hydrochlorothiazide in Combined Tablet Dosage Forms

    Get PDF
    Two new, rapid, precise, accurate and specific chromatographic methods were described for the simultaneous determination of olmesartan medoxomil and hydrochlorothiazide in combined tablet dosage forms. The first method was based on reversed phase liquid chromatography using an Eurosphere 100 RP C18 column (250 × 4.6 mm ID, 5 μm). The mobile phase was methanol–0.05% o-phosphoric acid (60:40 v/v) at a flow rate of 1.0 mL min−1. Commercially available tablets and laboratory mixtures containing both drugs were assayed and detected using a UV detector at 270 nm. The second method involved silica gel 60 F254 high performance thin layer chromatography and densitometric detection at 254 nm using acetonitrile–ethyl acetate–glacial acid (7:3:0.4 v/v/v) as the mobile phase. Calibration curves ranged between 200–600 and 125–375 ng spot−1 for olmesartan and hydrochlorothiazide, respectively

    Effect of Salt Valency and Concentration on Shear and Extensional Rheology of Aqueous Polyelectrolyte Solutions For Enhanced Oil Recovery

    Get PDF
    The injection of polymer solutions into an oil basin can lead to enhanced oil recovery (EOR) by increasing the microscopic sweep of the reservoir, improving the water-oil motility ratio, and thus leading to greater yield from oil fields. In this contribution, we characterize both shear and extensional rheological response of aqueous solutions of partially hydrolyzed polyacrylamide (HPAM), the most commonly used polymer for EOR, for velocity gradients in both the flow direction (extensional) and perpendicular to flow (shear) arise in EOR applications. As HPAM is a charged polymer, to better emulate the environment in oil basins, the rheological response was investigated in presence of salt, sodium chloride, and calcium chloride, with concentrations 3.7 × 10−4 − 1.5 M, as a function of polymer molecular weight (2–10 million g/mol) and concentration (0.005–0.3 wt%). The extensional relaxation times and extensional viscosity are measured using dripping-onto-substrate (DoS) rheometry protocols, and a commercial shear rheometer was utilized for characterizing the shear rheology response. The polyelectrolyte solutions formed by HPAM exhibit shear thinning in steady shear, but show strain hardening in response to extensional flow. Even though an increase in monovalent salt concentration leads to a decrease in both shear viscosity and extensional relaxation times, an increase in divalent salt concentration leads to an increase in extensional viscosity and relaxation time, implying that ion coordination can play a role in the presence of multivalent ions

    A fast and intuitive method for calculating dynamic network reconfiguration and node flexibility

    Get PDF
    Dynamic interactions between brain regions, either during rest or performance of cognitive tasks, have been studied extensively using a wide variance of methods. Although some of these methods allow elegant mathematical interpretations of the data, they can easily become computationally expensive or difficult to interpret and compare between subjects or groups. Here, we propose an intuitive and computationally efficient method to measure dynamic reconfiguration of brain regions, also termed flexibility. Our flexibility measure is defined in relation to an a-priori set of biologically plausible brain modules (or networks) and does not rely on a stochastic data-driven module estimation, which, in turn, minimizes computational burden. The change of affiliation of brain regions over time with respect to these a-priori template modules is used as an indicator of brain network flexibility. We demonstrate that our proposed method yields highly similar patterns of whole-brain network reconfiguration (i.e., flexibility) during a working memory task as compared to a previous study that uses a data-driven, but computationally more expensive method. This result illustrates that the use of a fixed modular framework allows for valid, yet more efficient estimation of whole-brain flexibility, while the method additionally supports more fine-grained (e.g. node and group of nodes scale) flexibility analyses restricted to biologically plausible brain networks.</p

    Enantiopure Dinaphtho[2,3-b:2,3-f]thieno[3,2-b]thiophenes: Reaching High Magnetoresistance Effect in OFETs

    Get PDF
    Chiral molecules are known to behave as spin filters due to the chiral induced spin selectivity (CISS) effect. Chirality can be implemented in molecular semiconductors in order to study the role of the CISS effect in charge transport and to find new materials for spintronic applications. In this study, the design and synthesis of a new class of enantiopure chiral organic semiconductors based on the well-known dinaphtho[2,3-b:2,3-f]thieno[3,2-b]thiophene (DNTT) core functionalized with chiral alkyl side chains is presented. When introduced in an organic field-effect transistor (OFET) with magnetic contacts, the two enantiomers, (R)-DNTT and (S)-DNTT, show an opposite behavior with respect to the relative direction of the magnetization of the contacts, oriented by an external magnetic field. Each enantiomer displays an unexpectedly high magnetoresistance over one preferred orientation of the spin current injected from the magnetic contacts. The result is the first reported OFET in which the current can be switched on and off upon inversion of the direction of the applied external magnetic field. This work contributes to the general understanding of the CISS effect and opens new avenues for the introduction of organic materials in spintronic devices

    New aerodynamic lens injector for single particle diffractive imaging

    Get PDF
    An aerodynamic lens injector was developed specifically for the needs of single-particle diffractive imaging experiments at free-electron lasers. Its design allows for quick changes of injector geometries and focusing properties in order to optimize injection for specific individual samples. Here, we present results of its first use at the FLASH free-electron-laser facility. Recorded diffraction patterns of polystyrene spheres are modeled using Mie scattering, which allowed for the characterization of the particle beam under diffractive-imaging conditions and yield good agreement with particle-trajectory simulations

    Point of care coagulometry in prehospital emergency care: an observational study

    Get PDF
    Background: Haemostatic impairment can have a crucial impact on the outcome of emergency patients, especially in cases of concomitant antithrombotic drug treatment. In this prospective observational study we used a point of care (POC) coagulometer in a prehospital physician-based emergency medical system in order to test its validity and potential value in the treatment of emergency patients. Methods: During a study period of 12 months, patients could be included if venous access was mandatory for further treatment. The POC device CoaguChek® was used to assess international normalized ratio (INR) after ambulance arrival at the scene. Results were compared with in-hospital central laboratory assessment of INR. The gain of time was analysed as well as the potential value of POC testing through a questionnaire completed by the responsible prehospital emergency physician. Results: A total of 103 patients were included in this study. POC INR results were highly correlated with results of conventional assessment of INR (Bland-Altman-bias: 0.014). Using a cutoff value of INR >1.3, the device’s sensitivity to detect coagulopathy was 100 % with a specificity of 98.7 %. The median gain of time was 69 min. Treating emergency physicians considered the value of prehospital POC INR testing ‘high’ in 9 % and ‘medium’ in 21 % of all patients. In patients with tracer diagnosis ‘neurology’, the value of prehospital INR assessment was considered ‘high’ or ‘medium’ (63 %) significantly more often than in patients with non-neurological tracer diagnoses (24 %). Conclusions: Assessment of INR through a POC coagulometer is feasible in prehospital emergency care and provides valuable information on haemostatic parameters in patients. Questionnaire results suggest that POC INR testing may present a valuable technique in selected patients. Whether this information translates into an improved management of respective patients has to be evaluated in further studies
    • …
    corecore