15 research outputs found

    The ArT\'eMiS wide-field submillimeter camera: preliminary on-sky performances at 350 microns

    Full text link
    ArTeMiS is a wide-field submillimeter camera operating at three wavelengths simultaneously (200, 350 and 450 microns). A preliminary version of the instrument equipped with the 350 microns focal plane, has been successfully installed and tested on APEX telescope in Chile during the 2013 and 2014 austral winters. This instrument is developed by CEA (Saclay and Grenoble, France), IAS (France) and University of Manchester (UK) in collaboration with ESO. We introduce the mechanical and optical design, as well as the cryogenics and electronics of the ArTeMiS camera. ArTeMiS detectors are similar to the ones developed for the Herschel PACS photometer but they are adapted to the high optical load encountered at APEX site. Ultimately, ArTeMiS will contain 4 sub-arrays at 200 microns and 2x8 sub-arrays at 350 and 450 microns. We show preliminary lab measurements like the responsivity of the instrument to hot and cold loads illumination and NEP calculation. Details on the on-sky commissioning runs made in 2013 and 2014 at APEX are shown. We used planets (Mars, Saturn, Uranus) to determine the flat-field and to get the flux calibration. A pointing model was established in the first days of the runs. The average relative pointing accuracy is 3 arcsec. The beam at 350 microns has been estimated to be 8.5 arcsec, which is in good agreement with the beam of the 12 m APEX dish. Several observing modes have been tested, like On-The-Fly for beam-maps or large maps, spirals or raster of spirals for compact sources. With this preliminary version of ArTeMiS, we concluded that the mapping speed is already more than 5 times better than the previous 350 microns instrument at APEX. The median NEFD at 350 microns is 600 mJy.s1/2, with best values at 300 mJy.s1/2. The complete instrument with 5760 pixels and optimized settings will be installed during the first half of 2015.Comment: 11 pages, 11 figures. Presented at SPIE Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy VII, June 24, 2014. To be published in Proceedings of SPIE Volume 915

    Localized Surface Plasmon Resonance of Metallic Nanoparticles--Optical Property Characterization for Rational Applications

    Get PDF
    在光的激发下金属纳米结构中的自由电子能够发生群体性的振荡,进而产生表面等离激元(SPP)。发生等离激元共振时,金属纳米结构会将光束缚在表面,并在表面产生极强的电场增强。表面等离激元有两种类型:一类具有传播的特点,其表面等离激元能够在表面传播,称之为propagatingSPP;另一类不具有传播性,共振局域在一个很小的金属结构中,称之为localizedSPP,即局域表面等离激元共振(LSPR)。金属纳米颗粒就具有很强的表面等离激元共振的(LSPR)性质,使其对光产生增强的吸收和增强的散射,并表现出相关的热、光电场增强和热电子等效应。近年,随着纳米科技的发展,金属纳米粒子的LSPR效应已经成为一...The collective oscillation of free electrons in metal nanostructures excited with light is called surface plasmon polaritons (SPP). The light will be confined to a small area on the surface under the resonance condition (SPR), thus a giant enhancement in the electric field will be produced. There are two kinds of surface plasmon polaritons (SPP): one is propagating plasmon polaritons (PSPP), which...学位:理学博士院系专业:化学化工学院_物理化学(含化学物理)学号:2052010015366

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Get PDF
    The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory. Athena is a versatile observatory designed to address the Hot and Energetic Universe science theme, as selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), X-IFU aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over a hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR (i.e. in the course of its preliminary definition phase, so-called B1), browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters, such as the instrument efficiency, spectral resolution, energy scale knowledge, count rate capability, non X-ray background and target of opportunity efficiency. Finally, we briefly discuss the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, touch on communication and outreach activities, the consortium organisation and the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. The X-IFU will be provided by an international consortium led by France, The Netherlands and Italy, with ESA member state contributions from Belgium, Czech Republic, Finland, Germany, Poland, Spain, Switzerland, with additional contributions from the United States and Japan.The French contribution to X-IFU is funded by CNES, CNRS and CEA. This work has been also supported by ASI (Italian Space Agency) through the Contract 2019-27-HH.0, and by the ESA (European Space Agency) Core Technology Program (CTP) Contract No. 4000114932/15/NL/BW and the AREMBES - ESA CTP No.4000116655/16/NL/BW. This publication is part of grant RTI2018-096686-B-C21 funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe”. This publication is part of grant RTI2018-096686-B-C21 and PID2020-115325GB-C31 funded by MCIN/AEI/10.13039/501100011033

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Full text link
    The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).Comment: 48 pages, 29 figures, Accepted for publication in Experimental Astronomy with minor editin

    Enabling planetary science across light-years. Ariel Definition Study Report

    Get PDF
    Ariel, the Atmospheric Remote-sensing Infrared Exoplanet Large-survey, was adopted as the fourth medium-class mission in ESA's Cosmic Vision programme to be launched in 2029. During its 4-year mission, Ariel will study what exoplanets are made of, how they formed and how they evolve, by surveying a diverse sample of about 1000 extrasolar planets, simultaneously in visible and infrared wavelengths. It is the first mission dedicated to measuring the chemical composition and thermal structures of hundreds of transiting exoplanets, enabling planetary science far beyond the boundaries of the Solar System. The payload consists of an off-axis Cassegrain telescope (primary mirror 1100 mm x 730 mm ellipse) and two separate instruments (FGS and AIRS) covering simultaneously 0.5-7.8 micron spectral range. The satellite is best placed into an L2 orbit to maximise the thermal stability and the field of regard. The payload module is passively cooled via a series of V-Groove radiators; the detectors for the AIRS are the only items that require active cooling via an active Ne JT cooler. The Ariel payload is developed by a consortium of more than 50 institutes from 16 ESA countries, which include the UK, France, Italy, Belgium, Poland, Spain, Austria, Denmark, Ireland, Portugal, Czech Republic, Hungary, the Netherlands, Sweden, Norway, Estonia, and a NASA contribution

    Characterization of the detection chain of the Micro-channel X-ray Telescope

    No full text
    This paper describes the first performance tests and characterization of the detection chain of the Microchannel X-ray Telescope (MXT), one of the instruments on board the French-Chinese mission SVOM for the study of Gamma-Ray Bursts. The MXT detector consists of a back-illuminated 450 μm-thick fully-depleted framestore silicon pnCCD, operating in the 0.2 − 10 keV energy range. Featuring an imaging area of ≈ 4 cm2, the device is read out in parallel by two CAMEX ASICs and is powered and controlled by its dedicated Front-End Electronics. A complete setup based on a cryostat and a multi-energy X-ray source have been designed for the characterization of the detection chain. The tests, performed at ≈ −65 ◦C, demonstrate a spectral resolution of (82 ± 2) eV at 1.5 keV as well as a < 200 eV low-level threshold. Both of those results are in compliance with the performance requirements of the instrument

    The DRE, the digital readout electronics for Athena X-IFU

    No full text
    Event: SPIE Astronomical Telescopes + Instrumentation, 2014, Montréal, Quebec, Canada.We are developing the digital readout electronics (DRE) of the X-Ray Integral Field Unit (X-IFU), one of the two Athena focal plane instruments. This subsystem is made of two main parts: the DRE-DEMUX and the DRE-EP. With a frequency domain multiplexing (FDM) the DRE-DEMUX makes the readout of the 3 840 Transition Edge Sensors (TES) in 96 channels of 40 pixels each. It provides the AC signals to voltage-bias the TES, it demodulates the detector's data which are readout by a SQUID and low noise amplifiers and it linearizes the detection chain to increase its dynamic range. The feedback is computed with a specific technique, so called baseband feedback (BBFB) which ensures that the loop is stable even with long propagation and processing delays (i.e. a few μs) and with high frequency AC-bias (up to 5 MHz). This processing is partly analogue (anti aliasing and reconstruction filters) but mostly digital. The digital firmware is simultaneously applied to all the pixels in digital integrated circuits. After the demultiplexing the interface between the DRE-DEMUX and the DRE-EP has to cope with a data rate of 61.44 Gbps to transmit the data of the individual pixels. Then, the DRE-EP detects the events and computes their energy and grade according to their spectral quality: low resolution, medium resolution and high resolution (i.e. if two consecutive events are too close the estimate of the energy is less accurate). This processing is done in LEON based processor boards. At its output the DRE-EP provides the control unit of the instrument with a list including for each event its time of arrival, its energy, its location on the focal plane and its grade.Peer reviewe
    corecore