73 research outputs found

    NMR as evaluation strategy for cellular uptake of nanoparticles

    Get PDF
    Advanced nanostructured materials, such as gold nanoparticles, magnetic nanoparticles, and multifunctional materials, are nowadays used in many state-of-the-art biomedical application. However, although the engineering in this field is very advanced, there remain some fundamental problems involving the interaction mechanisms between nanostructures and cells or tissues. Here we show the potential of 1H NMR in the investigation of the uptake of two different kinds of nanostructures, that is, maghemite and gold nanoparticles, and of a chemotherapy drug (Temozolomide) in glioblastoma tumor cells. The proposed experimental protocol provides a new way to investigate the general problem of cellular uptake for a variety of biocompatible nanostructures and drugs. © 2014 American Chemical Society

    Clinical phenotype and outcome of hepatitis E virus - associated neuralgic amyotrophy

    Get PDF
    Objective: To determine the clinical phenotype and outcome in hepatitis E virus–associated neuralgic amyotrophy (HEV-NA). Methods: Cases of NA were identified in 11 centers from 7 European countries, with retrospective analysis of demographics, clinical/laboratory findings, and treatment and outcome. Cases of HEV-NA were compared with NA cases without evidence of HEV infection. Results: Fifty-seven cases of HEV-NA and 61 NA cases without HEV were studied. Fifty-six of 57 HEV-NA cases were anti-HEV IgM positive; 53/57 were IgG positive. In 38 cases, HEV RNA was recovered from the serum and in 1 from the CSF (all genotype 3). Fifty-one of 57 HEV-NA cases were anicteric; median alanine aminotransferase 259 IU/L (range 12–2,961 IU/L); in 6 cases, liver function tests were normal. HEV-NA cases were more likely to have bilateral involvement (80.0% vs 8.6%, p < 0.001), damage outside the brachial plexus (58.5% vs 10.5%, p < 0.01), including phrenic nerve and lumbosacral plexus injury (25.0% vs 3.5%, p = 0.01, and 26.4% vs 7.0%, p = 0.001), reduced reflexes (p = 0.03), sensory symptoms (p = 0.04) with more extensive damage to the brachial plexus. There was no difference in outcome between the 2 groups at 12 months. Conclusions: Patients with HEV-NA are usually anicteric and have a distinct clinical phenotype, with predominately bilateral asymmetrical involvement of, and more extensive damage to, the brachial plexus. Involvement outside the brachial plexus is more common in HEV-NA. The relationship between HEV and NA is likely to be causal, but is easily overlooked. Patients presenting with NA should be tested for HEV, irrespective of liver function test results. Prospective treatment/outcome studies of HEV-NA are warranted

    Lopinavir/Ritonavir and Darunavir/Cobicistat in Hospitalized COVID-19 Patients: Findings From the Multicenter Italian CORIST Study

    Get PDF
    Background: Protease inhibitors have been considered as possible therapeutic agents for COVID-19 patients. Objectives: To describe the association between lopinavir/ritonavir (LPV/r) or darunavir/cobicistat (DRV/c) use and in-hospital mortality in COVID-19 patients. Study Design: Multicenter observational study of COVID-19 patients admitted in 33 Italian hospitals. Medications, preexisting conditions, clinical measures, and outcomes were extracted from medical records. Patients were retrospectively divided in three groups, according to use of LPV/r, DRV/c or none of them. Primary outcome in a time-to event analysis was death. We used Cox proportional-hazards models with inverse probability of treatment weighting by multinomial propensity scores. Results: Out of 3,451 patients, 33.3% LPV/r and 13.9% received DRV/c. Patients receiving LPV/r or DRV/c were more likely younger, men, had higher C-reactive protein levels while less likely had hypertension, cardiovascular, pulmonary or kidney disease. After adjustment for propensity scores, LPV/r use was not associated with mortality (HR = 0.94, 95% CI 0.78 to 1.13), whereas treatment with DRV/c was associated with a higher death risk (HR = 1.89, 1.53 to 2.34, E-value = 2.43). This increased risk was more marked in women, in elderly, in patients with higher severity of COVID-19 and in patients receiving other COVID-19 drugs. Conclusions: In a large cohort of Italian patients hospitalized for COVID-19 in a real-life setting, the use of LPV/r treatment did not change death rate, while DRV/c was associated with increased mortality. Within the limits of an observational study, these data do not support the use of LPV/r or DRV/c in COVID-19 patients

    Neutrino Physics with JUNO

    Get PDF
    The Jiangmen Underground Neutrino Observatory (JUNO), a 20 kton multi-purposeunderground liquid scintillator detector, was proposed with the determinationof the neutrino mass hierarchy as a primary physics goal. It is also capable ofobserving neutrinos from terrestrial and extra-terrestrial sources, includingsupernova burst neutrinos, diffuse supernova neutrino background, geoneutrinos,atmospheric neutrinos, solar neutrinos, as well as exotic searches such asnucleon decays, dark matter, sterile neutrinos, etc. We present the physicsmotivations and the anticipated performance of the JUNO detector for variousproposed measurements. By detecting reactor antineutrinos from two power plantsat 53-km distance, JUNO will determine the neutrino mass hierarchy at a 3-4sigma significance with six years of running. The measurement of antineutrinospectrum will also lead to the precise determination of three out of the sixoscillation parameters to an accuracy of better than 1\%. Neutrino burst from atypical core-collapse supernova at 10 kpc would lead to ~5000inverse-beta-decay events and ~2000 all-flavor neutrino-proton elasticscattering events in JUNO. Detection of DSNB would provide valuable informationon the cosmic star-formation rate and the average core-collapsed neutrinoenergy spectrum. Geo-neutrinos can be detected in JUNO with a rate of ~400events per year, significantly improving the statistics of existing geoneutrinosamples. The JUNO detector is sensitive to several exotic searches, e.g. protondecay via the pK++νˉp\to K^++\bar\nu decay channel. The JUNO detector will providea unique facility to address many outstanding crucial questions in particle andastrophysics. It holds the great potential for further advancing our quest tounderstanding the fundamental properties of neutrinos, one of the buildingblocks of our Universe

    Potential of Core-Collapse Supernova Neutrino Detection at JUNO

    Get PDF
    JUNO is an underground neutrino observatory under construction in Jiangmen, China. It uses 20kton liquid scintillator as target, which enables it to detect supernova burst neutrinos of a large statistics for the next galactic core-collapse supernova (CCSN) and also pre-supernova neutrinos from the nearby CCSN progenitors. All flavors of supernova burst neutrinos can be detected by JUNO via several interaction channels, including inverse beta decay, elastic scattering on electron and proton, interactions on C12 nuclei, etc. This retains the possibility for JUNO to reconstruct the energy spectra of supernova burst neutrinos of all flavors. The real time monitoring systems based on FPGA and DAQ are under development in JUNO, which allow prompt alert and trigger-less data acquisition of CCSN events. The alert performances of both monitoring systems have been thoroughly studied using simulations. Moreover, once a CCSN is tagged, the system can give fast characterizations, such as directionality and light curve

    Detection of the Diffuse Supernova Neutrino Background with JUNO

    Get PDF
    As an underground multi-purpose neutrino detector with 20 kton liquid scintillator, Jiangmen Underground Neutrino Observatory (JUNO) is competitive with and complementary to the water-Cherenkov detectors on the search for the diffuse supernova neutrino background (DSNB). Typical supernova models predict 2-4 events per year within the optimal observation window in the JUNO detector. The dominant background is from the neutral-current (NC) interaction of atmospheric neutrinos with 12C nuclei, which surpasses the DSNB by more than one order of magnitude. We evaluated the systematic uncertainty of NC background from the spread of a variety of data-driven models and further developed a method to determine NC background within 15\% with {\it{in}} {\it{situ}} measurements after ten years of running. Besides, the NC-like backgrounds can be effectively suppressed by the intrinsic pulse-shape discrimination (PSD) capabilities of liquid scintillators. In this talk, I will present in detail the improvements on NC background uncertainty evaluation, PSD discriminator development, and finally, the potential of DSNB sensitivity in JUNO

    NMR as Evaluation Strategy for Cellular Uptake of Nanoparticles

    No full text
    Advanced nanostructured materials, such as gold nanoparticles, magnetic nanoparticles, and multifunctional materials, are nowadays used in many state-of-the-art biomedical application. However, although the engineering in this field is very advanced, there remain some fundamental problems involving the interaction mechanisms between nanostructures and cells or tissues. Here we show the potential of <sup>1</sup>H NMR in the investigation of the uptake of two different kinds of nanostructures, that is, maghemite and gold nanoparticles, and of a chemotherapy drug (Temozolomide) in glioblastoma tumor cells. The proposed experimental protocol provides a new way to investigate the general problem of cellular uptake for a variety of biocompatible nanostructures and drugs

    The role of the Italian scientific community in the first HyMeX SOP: an outstanding multidisciplinary experience

    Get PDF
    The first Special Observation Period (SOP1) field campaign of the HyMeX (HYdrological cycle in the Mediterranean EXperiment) program was held in fall 2012 and was devoted to the investigation of heavy precipitation and floods in the Western Mediterranean. Both the Italian research and operational meteorological communities actively participated by providing a valuable contribution through the organization of an ad hoc national Operational Centre. The paper presents an overview of this participation, resulting in a fruitful multidisciplinary experience able to build a bridge between academia, researchers, forecasters, end-users and decision makers. The benefits provided by the wide national involvement and the consequent possible national impacts and progress are discussed within the context of the complex organization of meteorology in Italy
    corecore