6 research outputs found

    Intraperitoneal drain placement and outcomes after elective colorectal surgery: international matched, prospective, cohort study

    Get PDF
    Despite current guidelines, intraperitoneal drain placement after elective colorectal surgery remains widespread. Drains were not associated with earlier detection of intraperitoneal collections, but were associated with prolonged hospital stay and increased risk of surgical-site infections.Background Many surgeons routinely place intraperitoneal drains after elective colorectal surgery. However, enhanced recovery after surgery guidelines recommend against their routine use owing to a lack of clear clinical benefit. This study aimed to describe international variation in intraperitoneal drain placement and the safety of this practice. Methods COMPASS (COMPlicAted intra-abdominal collectionS after colorectal Surgery) was a prospective, international, cohort study which enrolled consecutive adults undergoing elective colorectal surgery (February to March 2020). The primary outcome was the rate of intraperitoneal drain placement. Secondary outcomes included: rate and time to diagnosis of postoperative intraperitoneal collections; rate of surgical site infections (SSIs); time to discharge; and 30-day major postoperative complications (Clavien-Dindo grade at least III). After propensity score matching, multivariable logistic regression and Cox proportional hazards regression were used to estimate the independent association of the secondary outcomes with drain placement. Results Overall, 1805 patients from 22 countries were included (798 women, 44.2 per cent; median age 67.0 years). The drain insertion rate was 51.9 per cent (937 patients). After matching, drains were not associated with reduced rates (odds ratio (OR) 1.33, 95 per cent c.i. 0.79 to 2.23; P = 0.287) or earlier detection (hazard ratio (HR) 0.87, 0.33 to 2.31; P = 0.780) of collections. Although not associated with worse major postoperative complications (OR 1.09, 0.68 to 1.75; P = 0.709), drains were associated with delayed hospital discharge (HR 0.58, 0.52 to 0.66; P < 0.001) and an increased risk of SSIs (OR 2.47, 1.50 to 4.05; P < 0.001). Conclusion Intraperitoneal drain placement after elective colorectal surgery is not associated with earlier detection of postoperative collections, but prolongs hospital stay and increases SSI risk

    Studying the combined effect of layer thickness and solid loading percentage for improving the compressive strength of 3D printed β-TCP scaffold by LCD technique

    No full text
    Customized 3D printed bio-ceramic scaffolds with complex shapes can be fabricated by Liquid Crystal Display (LCD) technology. In this study we investigated the combined effect of the solid loading percentage of the β-Tricalcium phosphate (β-TCP) bio-ceramic powder and the 3D printing layer thickness on the compressive strength of the 3D printed bio-ceramic scaffolds using LCD technique. Three different high solid loadings (40, 60 and 80 vol%) of β-TCP were mixed with resin in the presence of Oleic acid prior to the 3D printing. The β-TCP:resin slurry was used to fabricate scaffolds by using three different layer thicknesses (50 μm, 100 μm and 150 μm). The 3D printed green scaffolds were thermally debinded at 530 °C for 8 h and sintered at 1000 °C for 6 h based on the TGA and DSC thermal analysis of the β-TCP-resin slurry. The x-ray diffraction (XRD) and the Fourier transform infrared (FTIR) spectroscopy analysis confirmed that the β-TCP structure is preserved after scaffold fabrication. The Scanning Electron Microscopy (SEM) analysis showed the surface morphology of the scaffolds with internal pores, micro porosity, and localized delamination. The main finding of the results suggests that decreasing the layer thickness and the solid loading will enhance the compressive strength of the scaffold. Maximum compressive strength attained was (0.19 ± 0.01 MPa) for scaffolds with 40 % solid loadings, layer thickness of 50 μm and porosity 83.49 %. These results demonstrate the potential of using the low-cost LCD 3D printing in fabricating a customized porous β-TCP scaffolds for bone tissue engineering

    Intraperitoneal drain placement and outcomes after elective colorectal surgery: international matched, prospective, cohort study

    Get PDF
    Many surgeons routinely place intraperitoneal drains after elective colorectal surgery. However, enhanced recovery after surgery guidelines recommend against their routine use owing to a lack of clear clinical benefit. This study aimed to describe international variation in intraperitoneal drain placement and the safety of this practice

    Evaluation of prognostic risk models for postoperative pulmonary complications in adult patients undergoing major abdominal surgery: a systematic review and international external validation cohort study

    Get PDF
    Background Stratifying risk of postoperative pulmonary complications after major abdominal surgery allows clinicians to modify risk through targeted interventions and enhanced monitoring. In this study, we aimed to identify and validate prognostic models against a new consensus definition of postoperative pulmonary complications. Methods We did a systematic review and international external validation cohort study. The systematic review was done in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We searched MEDLINE and Embase on March 1, 2020, for articles published in English that reported on risk prediction models for postoperative pulmonary complications following abdominal surgery. External validation of existing models was done within a prospective international cohort study of adult patients (≥18 years) undergoing major abdominal surgery. Data were collected between Jan 1, 2019, and April 30, 2019, in the UK, Ireland, and Australia. Discriminative ability and prognostic accuracy summary statistics were compared between models for the 30-day postoperative pulmonary complication rate as defined by the Standardised Endpoints in Perioperative Medicine Core Outcome Measures in Perioperative and Anaesthetic Care (StEP-COMPAC). Model performance was compared using the area under the receiver operating characteristic curve (AUROCC). Findings In total, we identified 2903 records from our literature search; of which, 2514 (86·6%) unique records were screened, 121 (4·8%) of 2514 full texts were assessed for eligibility, and 29 unique prognostic models were identified. Nine (31·0%) of 29 models had score development reported only, 19 (65·5%) had undergone internal validation, and only four (13·8%) had been externally validated. Data to validate six eligible models were collected in the international external validation cohort study. Data from 11 591 patients were available, with an overall postoperative pulmonary complication rate of 7·8% (n=903). None of the six models showed good discrimination (defined as AUROCC ≥0·70) for identifying postoperative pulmonary complications, with the Assess Respiratory Risk in Surgical Patients in Catalonia score showing the best discrimination (AUROCC 0·700 [95% CI 0·683–0·717]). Interpretation In the pre-COVID-19 pandemic data, variability in the risk of pulmonary complications (StEP-COMPAC definition) following major abdominal surgery was poorly described by existing prognostication tools. To improve surgical safety during the COVID-19 pandemic recovery and beyond, novel risk stratification tools are required. Funding British Journal of Surgery Society

    Safety and efficacy of intraperitoneal drain placement after emergency colorectal surgery. An international, prospective cohort study

    No full text
    Intraperitoneal drains are often placed during emergency colorectal surgery. However, there is a lack of evidence supporting their use. This study aimed to describe the efficacy and safety of intraperitoneal drain placement after emergency colorectal surgery. Method: COMPlicAted intra-abdominal collectionS after colorectal Surgery (COMPASS) is a prospective, international, cohort study into which consecutive adult patients undergoing emergency colorectal surgery were enrolled (from 3 February 2020 to 8 March 2020). The primary outcome was the rate of intraperitoneal drain placement. Secondary outcomes included rate and time-to-diagnosis of postoperative intraperitoneal collections, rate of surgical site infections (SSIs), time to discharge and 30-day major postoperative complications (Clavien-Dindo III-V). Multivariable logistic and Cox proportional hazards regressions were used to estimate the independent association of the outcomes with drain placement. Results: Some 725 patients (median age 68.0 years; 349 [48.1%] women) from 22 countries were included. The drain insertion rate was 53.7% (389 patients). Following multivariable adjustment, drains were not significantly associated with reduced rates (odds ratio [OR] = 1.56, 95% CI: 0.48-5.02, p = 0.457) or earlier detection (hazard ratio [HR] = 1.07, 95% CI: 0.61-1.90, p = 0.805) of collections. Drains were not significantly associated with worse major postoperative complications (OR = 1.26, 95% CI: 0.67-2.36, p = 0.478), delayed hospital discharge (HR = 1.11, 95% CI: 0.91-1.36, p = 0.303) or increased risk of SSIs (OR = 1.61, 95% CI: 0.87-2.99, p = 0.128). Conclusion: This is the first study investigating placement of intraperitoneal drains following emergency colorectal surgery. The safety and clinical benefit of drains remain uncertain. Equipoise exists for randomized trials to define the safety and efficacy of drains in emergency colorectal surgery
    corecore