11 research outputs found

    New version of a laboratory impact device for firmness sensing of fruits.

    Get PDF
    Results of previous studies conducted by different researchers have shown that impact techniques can be used to evaluate firmness (Delwiche et al., 1989; Delwiche et al.;1996; Jaren et al., 1992; Ruiz Altisent et al., 1996). To impact the fruit with a small spherical impactor of known mass and radius of curvature and measure the acceleration of the impactor is a technique described by Chen et al. (1985) and used by several researchers for sensing fruit firmness (Jaren et al., 1992; Correa et al.; 1992). The advantages of this method vs. a force sensor that measures the force as a function of time is that the measured impact-acceleration response is independent of the fruit mass and is less sensitive to the variation in the radius of curvature of the fruit (Chen et al., 1996). Ruiz Altisent et al. (1993) developed and used a 50 g impactor with a 19 mm diameter spherical tip, dropping from different height for fruits (apples, pears, avocados, melons, peaches ...). Another impact device for firmness sensing of fruits was developed by Chen and Ruiz Altisent (1996). They designed and fabricated an experimental low-mass impact sensor for high-speed sensing of fruit firmness. The impactor consisted of a semi-spherical impacting tip attached to the end (near the centre of percussion) of a pivoting arm. Impact is done by swinging the impactor to collide with the fruit. It has been implemented for on-line use. In both devices a small accelerometer is mounted behind the impacting tip. Lateral impactor and vertical impactor have been used in laboratory and the results from non-destructive impact tests have contributed to standardise methods to measure fruit firmness: Barreiro (1992) compared impact parameters and results of Magness-Taylor penetration tests for apples, pears, apricots [and peaches; Agulheiro (1994) studied the behaviour of the impact parameters during seven weeks of cold storage of two melon varieties; Ortiz (1998) used low energy impact and NIR procedures to segregate non crispy, non firm and soft peaches. Steinmetz (1996) compared various non-destructive firmness sensors, based on sound, impact and micro-deformation

    Dispositivo impactador de laboratorio para la determinación de la firmeza en fruta: una nueva versión.

    Get PDF
    Se ha desarrollado una nueva versión de un dispositivo impactador para obtener un sistema versátil y de fácil manejo. La resolución, la precisión y la relación señal-ruido son mayores en el nuevo sistema que en prototipos anteriores. Se ha realizado un diseño de experimentos con diferentes materiales usando el nuevo y el antiguo impactador para comprobar las mejoras conseguidas

    Evaluation of soil mechanic resistance and seed depth placement in a maize crop seed under different soil management practices

    Get PDF
    Com o objetivo de estudar a influência da resistência mecânica do solo na distribuição vertical de semente obtida por semeadores numa cultura de milho, realizou-se na campanha de 2011 um estudo de campo na região do Alentejo, sendo a operação de sementeira feita sob diferentes praticas culturais: mobilização convencional, mobilização mínima e sementeira direta. Em sementeira direta foram ainda testadas duas velocidades de trabalho, 4 km-1 e 6 km-1. A profundidade de sementeira foi determinada a partir da medição do comprimento do mesocótilo do milho após a emergência da cultura. A média, desvio padrão, coeficiente de variação e correlação dos valores de resistência ao rompimento do solo e profundidade de sementeira foram determinados. Os resultados demonstraram que independentemente da pratica cultural utilizada se verificou uma correlação negativa entre os valores encontrados para a resistência ao rompimento do solo e os valores de profundidade de deposição da semente, sendo o valor mais acentuado na condição de sementeira direta (r = - 0.77) à velocidade de trabalho de 4 km-1. A melhor performance de sementeira foi conseguida em sementeira direta com o aumento de velocidade de trabalho de 4 para 6 km-1 com um coeficiente de variação de 10.1%. A análise de variância demonstrou haverem diferenças significativas nas profundidades de sementeira causadas pela resistência do solo e pela velocidade de trabalho do semeador de sementeira direta

    Calibración de una nariz electrónica tipo QCM y relación con las especificaciones para la calidad de la pera.

    Get PDF
    Las microbalanzas de cristal de cuarzo (QCM), son mecanismos piezoeléctricos, para transformarlos en sensores químicos es necesario recubrirlos con una capa de material capaz de capturar las moléculas del ambiente. Cuando una masa es adsorbida sobre la superficie del cristal, la frecuencia de oscilación cambia en proporción a la cantidad de masa (Di Natale et al. 1997). La respuesta de los sensores depende de numerosos factores que pueden ser difíciles de controlar, tales como la temperatura y la humedad del gas portador. Todos estos factores producen cambios en la selectividad de los sensores que afectan a la reproducibilidad de las medidas. A pesar de la existencia de numerosos estudios no existe ningún procedimiento establecido para la calibración de las QCM en relación con la sensibilidad necesaria en los sensores para el aseguramiento de la calidad en pera o en otras frutas

    Leaf litter traits of invasive alien species slow down decomposition compared to Spanish natives: a broad phylogenetic comparison.

    Get PDF
    Leaf traits related to the performance of invasive alien species can influence nutrient cycling through litter decomposition. However, there is no consensus yet about whether there are consistent differences in functional leaf traits between invasive and native species that also manifest themselves through their "after life" effects on litter decomposition. When addressing this question it is important to avoid confounding effects of other plant traits related to early phylogenetic divergences and to understand the mechanism underlying the observed results to predict which invasive species will exert larger effects on nutrient cycling. We compared initial leaf litter traits, and their effect on decomposability as tested in standardized incubations, in 19 invasive-native pairs of co-familial species from Spain. They included 12 woody and seven herbaceous alien species representative of the Spanish invasive flora. The predictive power of leaf litter decomposition rates followed the order: growth form > family > status (invasive vs. native) > leaf type. Within species pairs litter decomposition tended to be slower and more dependent on N and P in invaders than in natives. This difference was likely driven by the higher lignin content of invader leaves. Although our study has the limitation of not representing the natural conditions from each invaded community, it suggests a potential slowing down of the nutrient cycle at ecosystem scale upon invasion. © Springer-Verlag 2009

    White matter integrity in dyskinetic cerebral palsy : Relationship with intelligence quotient and executive function

    No full text
    Altres ajuts: Generalitat de Catalunya (2014SGR98)Dyskinetic cerebral palsy (CP) is one of the most disabling motor types of CP and has been classically associated with injury to the basal ganglia and thalamus. Although cognitive dysfunction is common in CP, there is a paucity of published quantitative analyses investigating the relationship between white matter (WM) microstructure and cognition in this CP type. This study aims (1) to compare brain WM microstructure between people with dyskinetic CP and healthy controls, (2) to identify brain regions where WM microstructure is related to intelligence and (3) to identify brain regions where WM microstructure is related to executive function in people with dyskinetic CP and (4) to identify brain regions where the correlations are different between controls and people with CP in IQ and executive functions. Thirty-three participants with dyskinetic CP (mean ± SD age: 24.42 ± 12.61, 15 female) were age and sex matched with 33 controls. Participants underwent a comprehensive neuropsychological battery to assess intelligence quotient (IQ) and four executive function domains (attentional control, cognitive flexibility, goal setting and information processing). Diffusion weighted MRI scans were acquired at 3T. Voxel-based whole brain groupwise analyses were used to compare fractional anisotropy (FA) and of the CP group to the matched controls using a general lineal model. Further general linear models were used to identify regions where white matter FA correlated with IQ and each of the executive function domains. White matter FA was significantly reduced in the CP group in all cerebral lobes, predominantly in regions connected with the parietal and to a lesser extent the temporal lobes. There was no significant correlation between IQ or any of the four executive function domains and WM microstructure in the control group. In participants with CP, lower IQ was associated with lower FA in all cerebral lobes, predominantly in locations that also showed reduced FA compared to controls. Attentional control, goal setting and information processing did not correlate with WM microstructure in the CP group. Cognitive flexibility was associated with FA in regions known to contain connections with the frontal lobe (such as the superior longitudinal fasciculus and cingulum) as well as regions not known to contain tracts directly connected with the frontal lobe (such as the posterior corona radiata, posterior thalamic radiation, retrolenticular part of internal capsule, tapetum, body and splenium of corpus callosum). The widespread loss in the integrity of WM tissue is mainly located in the parietal lobe and related to IQ in dyskinetic CP. Unexpectedly, executive functions are only related with WM microstructure in regions containing fronto-cortical and posterior cortico-subcortical pathways, and not being specifically related to the state of fronto-striatal pathways which might be due to brain reorganization. Further studies of this nature may improve our understanding of the neurobiological bases of cognitive impairments after early brain insult

    Clinical presentation, aetiology and outcome of infective endocarditis. Results of the ESC-EORP EURO-ENDO (European infective endocarditis) registry: a prospective cohort study

    No full text
    The EURO-ENDO registry aimed to study the management and outcomes of patients with infective endocarditis (IE). AIMS: The EURO-ENDO registry aimed to study the management and outcomes of patients with infective endocarditis (IE). METHODS AND RESULTS: Prospective cohort of 3116 adult patients (2470 from Europe, 646 from non-ESC countries), admitted to 156 hospitals in 40 countries between January 2016 and March 2018 with a diagnosis of IE based on ESC 2015 diagnostic criteria. Clinical, biological, microbiological, and imaging [echocardiography, computed tomography (CT) scan, 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT)] data were collected. Infective endocarditis was native (NVE) in 1764 (56.6%) patients, prosthetic (PVIE) in 939 (30.1%), and device-related (CDRIE) in 308 (9.9%). Infective endocarditis was community-acquired in 2046 (65.66%) patients. Microorganisms involved were staphylococci in 1085 (44.1%) patients, oral streptococci in 304 (12.3%), enterococci in 390 (15.8%), and Streptococcus gallolyticus in 162 (6.6%). 18F-fluorodeoxyglucose positron emission tomography/computed tomography was performed in 518 (16.6%) patients and presented with cardiac uptake (major criterion) in 222 (42.9%) patients, with a better sensitivity in PVIE (66.8%) than in NVE (28.0%) and CDRIE (16.3%). Embolic events occurred in 20.6% of patients, and were significantly associated with tricuspid or pulmonary IE, presence of a vegetation and Staphylococcus aureus IE. According to ESC guidelines, cardiac surgery was indicated in 2160 (69.3%) patients, but finally performed in only 1596 (73.9%) of them. In-hospital death occurred in 532 (17.1%) patients and was more frequent in PVIE. Independent predictors of mortality were Charlson index, creatinine > 2\u2009mg/dL, congestive heart failure, vegetation length > 10 mm, cerebral complications, abscess, and failure to undertake surgery when indicated. CONCLUSION: Infective endocarditis is still a life-threatening disease with frequent lethal outcome despite profound changes in its clinical, microbiological, imaging, and therapeutic profiles

    Predictors of embolism and death in left-sided infective endocarditis: the European Society of Cardiology EURObservational Research Programme European Infective Endocarditis registry

    No full text
    International audienceBackground and Aims Even though vegetation size in infective endocarditis (IE) has been associated with embolic events (EEs) and mortality risk, it is unclear whether vegetation size associated with these potential outcomes is different in left-sided IE (LSIE). This study aimed to seek assessing the vegetation cut-off size as predictor of EE or 30-day mortality for LSIE and to determine risk predictors of these outcomes. Methods The European Society of Cardiology EURObservational Research Programme European Infective Endocarditis is a prospective, multicentre registry including patients with definite or possible IE throughout 2016–18. Cox multivariable logistic regression analysis was performed to assess variables associated with EE or 30-day mortality. Results There were 2171 patients with LSIE (women 31.5%). Among these affected patients, 459 (21.1%) had a new EE or died in 30 days. The cut-off value of vegetation size for predicting EEs or 30-day mortality was >10 mm [hazard ratio (HR) 1.38, 95% confidence interval (CI) 1.13–1.69, P = .0015]. Other adjusted predictors of risk of EE or death were as follows: EE on admission (HR 1.89, 95% CI 1.54–2.33, P < .0001), history of heart failure (HR 1.53, 95% CI 1.21–1.93, P = .0004), creatinine >2 mg/dL (HR 1.59, 95% CI 1.25–2.03, P = .0002), Staphylococcus aureus (HR 1.36, 95% CI 1.08–1.70, P = .008), congestive heart failure (HR 1.40, 95% CI 1.12–1.75, P = .003), presence of haemorrhagic stroke (HR 4.57, 95% CI 3.08–6.79, P < .0001), alcohol abuse (HR 1.45, 95% CI 1.04–2.03, P = .03), presence of cardiogenic shock (HR 2.07, 95% CI 1.29–3.34, P = .003), and not performing left surgery (HR 1.30 95% CI 1.05–1.61, P = .016) (C-statistic = .68). Conclusions Prognosis after LSIE is determined by multiple factors, including vegetation size

    Optimization of adsorptive removal of α-toluic acid by CaO2 nanoparticles using response surface methodology

    Get PDF
    The present work addresses the optimization of process parameters for adsorptive removal of α-toluic acid by calcium peroxide (CaO2) nanoparticles using response surface methodology (RSM). CaO2 nanoparticles were synthesized by chemical precipitation method and confirmed by Transmission electron microscopy (TEM) and high-resolution TEM (HRTEM) analysis which shows the CaO2 nanoparticles size range of 5–15 nm. A series of batch adsorption experiments were performed using CaO2 nanoparticles to remove α-toluic acid from the aqueous solution. Further, an experimental based central composite design (CCD) was developed to study the interactive effect of CaO2 adsorbent dosage, initial concentration of α-toluic acid, and contact time on α-toluic acid removal efficiency (response) and optimization of the process. Analysis of variance (ANOVA) was performed to determine the significance of the individual and the interactive effects of variables on the response. The model predicted response showed a good agreement with the experimental response, and the coefficient of determination, (R2) was 0.92. Among the variables, the interactive effect of adsorbent dosage and the initial α-toluic acid concentration was found to have more influence on the response than the contact time. Numerical optimization of process by RSM showed the optimal adsorbent dosage, initial concentration of α-toluic acid, and contact time as 0.03 g, 7.06 g/L, and 34 min respectively. The predicted removal efficiency was 99.50%. The experiments performed under these conditions showed α-toluic acid removal efficiency up to 98.05%, which confirmed the adequacy of the model prediction
    corecore