30 research outputs found

    Balance between matrix metalloproteinases (MMP) and tissue inhibitors of metalloproteinases (TIMP) in the cervical mucus plug estimated by determination of free non-complexed TIMP

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The cervical mucus plug (CMP) is a semi-solid structure with antibacterial properties positioned in the cervical canal during pregnancy. The CMP contains high concentrations of matrix metalloproteinase 8 and 9 (MMP-8, MMP-9) and tissue inhibitor of metalloproteinase 1 (TIMP-1). This indicates a potential to degrade extracellular matrix components depending on the balance between free non-complexed inhibitors and active enzymes.</p> <p>Methods</p> <p>Thirty-two CMPs collected during active labor at term were analyzed. Twelve CMPs were separated into a cellular and an extracellular/fluid phase and analyzed by gelatin and reverse zymography to reveal MMP and TIMP location. Twenty samples were homogenized, extracted and studied by the TIMP activity assay based on gelatin zymography. Enzyme-linked immunosorbent assay (ELISA) was used to determine TIMP-1, MMP-8 and MMP-9 protein concentrations, and gelatin and reverse zymography used to identify gelatinases and TIMPs, respectively. The Western blotting technique was applied for semi-quantification of alpha2-macroglobulin. An ELISA activity assay was used to detect MMP-8 and MMP-9 activity.</p> <p>Results</p> <p>ProMMP-2, proMMP-9, TIMP-1 and TIMP-2 were almost exclusively located in the fluid phase compared to the cellular phase of the CMP. All the extracted samples contained MMP-8, MMP-9, TIMP-1, TIMP-2 and alpha2-macroglobulin. Free non-complexed TIMP was detected in all the samples analyzed by the TIMP activity assay and was associated with TIMP-1 protein (R = 0.71, p < 0.001) and with the TIMP/MMP molar ratio (1.7 (1.1–2.5) (mean (95% confidence interval)) (R = 0.65, p = 0.002). The ELISA activity assay showed no activity from MMP-8 or MMP-9.</p> <p>Conclusion</p> <p>Due to their extracellular location, potential proteolytic activity from neutrophil-derived MMPs in the CMP could exert a biological impact on cervical dilatation and fetal membrane rupture at term. The functional TIMP activity assay, revealing excess non-complexed TIMP, and a molar inhibitor/enzyme ratio above unity, indicate that refined MMP control prevents CMP-originated proteolytic activity in the surrounding tissue.</p

    Function and failure of the fetal membrane : modelling the mechanics of the chorion and amnion

    Get PDF
    The fetal membrane surrounds the fetus during pregnancy and is a thin tissue composed of two layers, the chorion and the amnion. While rupture of this membrane normally occurs at term, preterm rupture can result in increased risk of fetal mortality and morbidity, as well as danger of infection in the mother. Although structural changes have been observed in the membrane in such cases, the mechanical behaviour of the human fetal membrane in vivo remains poorly understood and is challenging to investigate experimentally. Therefore, the objective of this study was to develop simplified finite element models to investigate the mechanical behaviour and rupture of the fetal membrane, particularly its constituent layers, under various physiological conditions. It was found that modelling the chorion and amnion as a single layer predicts remarkably different behaviour compared with a more anatomically-accurate bilayer, significantly underestimating stress in the amnion and under-predicting the risk of membrane rupture. Additionally, reductions in chorion-amnion interface lubrication and chorion thickness (reported in cases of preterm rupture) both resulted in increased membrane stress. Interestingly, the inclusion of a weak zone in the fetal membrane that has been observed to develop overlying the cervix would likely cause it to fail at term, during labour. Finally, these findings support the theory that the amnion is the dominant structural component of the fetal membrane and is required to maintain its integrity. The results provide a novel insight into the mechanical effect of structural changes in the chorion and amnion, in cases of both normal and preterm rupture

    A model for the compressible, viscoelastic behavior of human amnion addressing tissue variability through a single parameter

    Get PDF
    A viscoelastic, compressible model is proposed to rationalize the recently reported response of human amnion in multiaxial relaxation and creep experiments. The theory includes two viscoelastic contributions responsible for the short- and long-term time- dependent response of the material. These two contributions can be related to physical processes: water flow through the tissue and dissipative characteristics of the collagen fibers, respectively. An accurate agreement of the model with the mean tension and kinematic response of amnion in uniaxial relaxation tests was achieved. By variation of a single linear factor that accounts for the variability among tissue samples, the model provides very sound predictions not only of the uniaxial relaxation but also of the uniaxial creep and strip-biaxial relaxation behavior of individual samples. This suggests that a wide range of viscoelastic behaviors due to patient-specific variations in tissue composition

    Mussel-mimetic tissue adhesive for fetal membrane repair: a standardized ex vivo evaluation using elastomeric membranes

    Full text link
    Objective Iatrogenic preterm premature rupture of membranes (iPPROM), the main complication of invasive interventions in the prenatal period, seriously limits the benefit of diagnostic or surgical prenatal procedures. This study aimed to evaluate preventive plugging of punctured fetal membranes in an ex vivo situation using a new mussel-mimetic tissue adhesive (mussel glue) to inhibit leakage. Methods A novel biomechanical test device that tests the closure of injured membranes under nearphysiological conditions was used. Mussel glue, a poly(ethylene glycol)-based hydrogel, was used to seal membrane defects of up to 3mm in mechanically well-defined elastomeric membranes with three different degrees of stiffness. Results Elastomeric test membranes were successfully employed for testing mussel glue under welldefined conditions. Mussel glue plugs were distended by up to 94%, which translated to an improved sealing efficiency on elastomeric membranes with high stiffness. For the stiffest membrane tested, a critical burst pressure of 48mbar (36mmHg) was accomplished in this ex vivo setting. Conclusions Mussel glue appears to efficiently seal membrane defects under well standardized ex vivo conditions. As repaired membranes resist pressures measured in amniotic cavities, mussel glue might represent a novel sealing method for iatrogenic membrane defects
    corecore