15 research outputs found

    Reconfiguração ótima de sistemas de distribuição para minimização de perdas de energia

    Get PDF
    This paper presents an algorithm for reconfiguration of Electrical Distribution Systems in order to minimize energy losses considering different load levels. This problem is considered as mixed integer non linear programming, in which a continuous function is used to handle the discrete variables. As consequence, the proposed model is solved using a step by step approach where the primal-dual interior point technique is solved at each step. The Lagrange multiplies are used to evaluate the sensitivity index for the reconfiguration process. The developed algorithm is tested in three systems of the literature.Este artigo apresenta um algoritmo para a reconfiguração ótima de Sistemas de Distribuição de Energia Elétrica (SDE), com o objetivo de minimizar a perda total de energia considerando diferentes níveis de carregamento. Trata-se de um problema de programação não linear inteira mista onde a variável discreta é modelada como uma função contínua. Como conseqüência, o problema proposto é resolvido através de um algoritmo passo a passo, onde em cada passo é utilizado o Método Primal-Dual de Pontos Interiores. Os multiplicadores de Lagrange são utilizados para compor o índice de sensibilidade no processo de reconfiguração. O algoritmo proposto é testado em três sistemas encontrados na literatura

    Influência da variação da produtividade das usinas hidroelétricas no cálculo da energia firme

    Get PDF
    In the present work, the problem associated to the firm energy evaluation is treated as a non linear optimization model, which allows the representation of the productivity variation of the hydro plants. The proposed model takes into account the individualized representation of the plants and the historical series of flows since the month of January of 1931. The proposed optimization problem will be solved using the Primal-Dual Interior Point Method. A case study will be presented including the Brazilian Interconnected National System. The results obtained show that the proposed methodology is promising, since it presents an energy market value more realistic when compared with existing methodologies.No presente trabalho, o problema associado ao cálculo da energia firme é tratado como um modelo não linear de otimização, o que permite a representação da variação da produtividade das usinas. No modelo proposto é considerada a representação individualizada das usinas bem como a série histórica de vazões desde o mês de janeiro de 1931. O problema de otimização proposto é resolvido através do método primal-dual de pontos interiores. Adicionalmente, é apresentado um estudo de caso abrangendo o Sistema Interligado Nacional Brasileiro. Os resultados obtidos mostram que a metodologia proposta é promissora, tendo em vista que apresenta um valor de mercado de energia mais realista quando comparado com outras metodologias

    Programming of thermoelectric generation systems based on a heuristic composition of ant colonies

    Get PDF
    a b s t r a c t Studies related to biologically inspired optimization techniques, which are used for daily operational scheduling of thermoelectric generation systems, indicate that combinations of biologically inspired computation methods together with other optimization techniques have an important role to play in obtaining the best solutions in the shortest amount of processing time. Following this line of research, this article uses a methodology based on optimization by an ant colony to minimize the daily scheduling cost of thermoelectric units. The proposed model uses a Sensitivity Matrix (SM) based on the information provided by the Lagrange multipliers to improve the biologically inspired search process. Thus, a percentage of the individuals in the colony use this information in the evolutionary process of the colony. The results achieved through the simulations indicate that the use of the SM results in quality solutions with a reduced number of individuals

    Stochastic Dynamic Programming Applied to Hydrothermal Power Systems Operation Planning Based on the Convex Hull Algorithm

    Get PDF
    This paper presents a new approach for the expected cost-to-go functions modeling used in the stochastic dynamic programming (SDP) algorithm. The SDP technique is applied to the long-term operation planning of electrical power systems. Using state space discretization, the Convex Hull algorithm is used for constructing a series of hyperplanes that composes a convex set. These planes represent a piecewise linear approximation for the expected cost-to-go functions. The mean operational costs for using the proposed methodology were compared with those from the deterministic dual dynamic problem in a case study, considering a single inflow scenario. This sensitivity analysis shows the convergence of both methods and is used to determine the minimum discretization level. Additionally, the applicability of the proposed methodology for two hydroplants in a cascade is demonstrated. With proper adaptations, this work can be extended to a complete hydrothermal system

    NLP based model for individual plant dispatch in long term hydrothermal planning

    Get PDF
    This paper presents a method to the hydrothermal dispatch using optimization techniques based on non linear programming techniques. To do so, the expected cost-to-go functions from a long term operation plannning strategic decision model are used. This decision model is based on stochastic dual dynamic programming and energy equivalent reservoirs. The proposed method considers a set of historical water inflow scenarios to the hydroelectric reservoirs. Those scenarios are used to simulate the long term operation planning to a given horizon. The results obtained from this disaggregation model (MIUH) are compared with those from the model officially adopted in the Brazilian power system, SUISHI-O. The latter is based on operation heuristics aiming at operating the reservoir maintaining the water storag e in similar levels, that is, trying to operate them in parallel.Este trabalho apresenta um modelo de despacho hidrotérmico à usinas individualizadas, utilizando métodos de otimização baseados em programação não linear. Para tanto, considera-se funções de custo futuro geradas por um modelo de decisão estratégica baseado em programação dinâmica e sistemas equivalentes de energia. O modelo proposto considera diversos cenários históricos de afluências hidrológicas às usinas hidrelétricas, os quais são simulados para um horizonte de planejamento da operação de médio/longo prazo. Os resultados obtidos através do modelo proposto, denominado Modelo Individualizado de Usinas Hidráulicas (MIUH), são comparados com os resultados obtidos a partir da utilização do modelo SUISHI-O adotado pelo Operador Nacional do Sistema Elétrico Brasileiro (ONS)

    Diretriz da Sociedade Brasileira de Cardiologia sobre Diagnóstico e Tratamento de Pacientes com Cardiomiopatia da Doença de Chagas

    Get PDF
    This guideline aimed to update the concepts and formulate the standards of conduct and scientific evidence that support them, regarding the diagnosis and treatment of the Cardiomyopathy of Chagas disease, with special emphasis on the rationality base that supported it.  Chagas disease in the 21st century maintains an epidemiological pattern of endemicity in 21 Latin American countries. Researchers and managers from endemic and non-endemic countries point to the need to adopt comprehensive public health policies to effectively control the interhuman transmission of T. cruzi infection, and to obtain an optimized level of care for already infected individuals, focusing on diagnostic and therapeutic opportunistic opportunities.   Pathogenic and pathophysiological mechanisms of the Cardiomyopathy of Chagas disease were revisited after in-depth updating and the notion that necrosis and fibrosis are stimulated by tissue parasitic persistence and adverse immune reaction, as fundamental mechanisms, assisted by autonomic and microvascular disorders, was well established. Some of them have recently formed potential targets of therapies.  The natural history of the acute and chronic phases was reviewed, with enhancement for oral transmission, indeterminate form and chronic syndromes. Recent meta-analyses of observational studies have estimated the risk of evolution from acute and indeterminate forms and mortality after chronic cardiomyopathy. Therapeutic approaches applicable to individuals with Indeterminate form of Chagas disease were specifically addressed. All methods to detect structural and/or functional alterations with various cardiac imaging techniques were also reviewed, with recommendations for use in various clinical scenarios. Mortality risk stratification based on the Rassi score, with recent studies of its application, was complemented by methods that detect myocardial fibrosis.  The current methodology for etiological diagnosis and the consequent implications of trypanonomic treatment deserved a comprehensive and in-depth approach. Also the treatment of patients at risk or with heart failure, arrhythmias and thromboembolic events, based on pharmacological and complementary resources, received special attention. Additional chapters supported the conducts applicable to several special contexts, including t. cruzi/HIV co-infection, risk during surgeries, in pregnant women, in the reactivation of infection after heart transplantation, and others.     Finally, two chapters of great social significance, addressing the structuring of specialized services to care for individuals with the Cardiomyopathy of Chagas disease, and reviewing the concepts of severe heart disease and its medical-labor implications completed this guideline.Esta diretriz teve como objetivo principal atualizar os conceitos e formular as normas de conduta e evidências científicas que as suportam, quanto ao diagnóstico e tratamento da CDC, com especial ênfase na base de racionalidade que a embasou. A DC no século XXI mantém padrão epidemiológico de endemicidade em 21 países da América Latina. Investigadores e gestores de países endêmicos e não endêmicos indigitam a necessidade de se adotarem políticas abrangentes, de saúde pública, para controle eficaz da transmissão inter-humanos da infecção pelo T. cruzi, e obter-se nível otimizado de atendimento aos indivíduos já infectados, com foco em oportunização diagnóstica e terapêutica. Mecanismos patogênicos e fisiopatológicos da CDC foram revisitados após atualização aprofundada e ficou bem consolidada a noção de que necrose e fibrose sejam estimuladas pela persistência parasitária tissular e reação imune adversa, como mecanismos fundamentais, coadjuvados por distúrbios autonômicos e microvasculares. Alguns deles recentemente constituíram alvos potenciais de terapêuticas. A história natural das fases aguda e crônica foi revista, com realce para a transmissão oral, a forma indeterminada e as síndromes crônicas. Metanálises recentes de estudos observacionais estimaram o risco de evolução a partir das formas aguda e indeterminada e de mortalidade após instalação da cardiomiopatia crônica. Condutas terapêuticas aplicáveis aos indivíduos com a FIDC foram abordadas especificamente. Todos os métodos para detectar alterações estruturais e/ou funcionais com variadas técnicas de imageamento cardíaco também foram revisados, com recomendações de uso nos vários cenários clínicos. Estratificação de risco de mortalidade fundamentada no escore de Rassi, com estudos recentes de sua aplicação, foi complementada por métodos que detectam fibrose miocárdica. A metodologia atual para diagnóstico etiológico e as consequentes implicações do tratamento tripanossomicida mereceram enfoque abrangente e aprofundado. Também o tratamento de pacientes em risco ou com insuficiência cardíaca, arritmias e eventos tromboembólicos, baseado em recursos farmacológicos e complementares, recebeu especial atenção. Capítulos suplementares subsidiaram as condutas aplicáveis a diversos contextos especiais, entre eles o da co-infecção por T. cruzi/HIV, risco durante cirurgias, em grávidas, na reativação da infecção após transplante cardíacos, e outros.    Por fim, dois capítulos de grande significado social, abordando a estruturação de serviços especializados para atendimento aos indivíduos com a CDC, e revisando os conceitos de cardiopatia grave e suas implicações médico-trabalhistas completaram esta diretriz.&nbsp

    Despacho de unidades termoelétricas considerando a rede de gás e a rede elétrica

    Get PDF
    Este artigo apresenta uma modelagem para o problema de Unit Commitment térmico incluindo as restrições de fluxo na rede elétrica e a disponibilidade de gás para a geração termoelétrica. O modelo proposto é formulado através de um problema de programação não linear onde inicialmente um problema de otimização linear é resolvido para determinar o sentido de fluxo de gás na rede. A formulação proposta para o problema não linear considera as restrições de pressão nos nós da rede bem como a priorização do gás para a indústria de base. Os resultados obtidos com a metodologia proposta evidenciam a forte influência dos limites da rede elétrica e da disponibilidade de gás no despacho das unidades termoelétricas
    corecore