11 research outputs found
Effect of blood glucose level on standardized uptake value (SUV) in F-18- FDG PET-scan : a systematic review and meta-analysis of 20,807 individual SUV measurements
Objectives To evaluate the effect of pre-scan blood glucose levels (BGL) on standardized uptake value (SUV) in F-18-FDG-PET scan. Methods A literature review was performed in the MEDLINE, Embase, and Cochrane library databases. Multivariate regression analysis was performed on individual datum to investigate the correlation of BGL with SUVmax and SUVmean adjusting for sex, age, body mass index (BMI), diabetes mellitus diagnosis, F-18-FDG injected dose, and time interval. The ANOVA test was done to evaluate differences in SUVmax or SUVmean among five different BGL groups (200 mg/dl). Results Individual data for a total of 20,807 SUVmax and SUVmean measurements from 29 studies with 8380 patients was included in the analysis. Increased BGL is significantly correlated with decreased SUVmax and SUVmean in brain (p <0.001, p <0.001,) and muscle (p <0.001, p <0.001) and increased SUVmax and SUVmean in liver (p = 0.001, p = 0004) and blood pool (p=0.008, p200 mg/dl had significantly lower SUVmax. Conclusion If BGL is lower than 200mg/dl no interventions are needed for lowering BGL, unless the liver is the organ of interest. Future studies are needed to evaluate sensitivity and specificity of FDG-PET scan in diagnosis of malignant lesions in hyperglycemia.Peer reviewe
Paclitaxel-induced dermal hypersensitivity lesions: 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/computed tomography
Paclitaxel is frequently used for the treatment of patients with nonsmall cell lung cancer. Hypersensitivity reactions (HSRs) have been one of the toxicities observed with administration of paclitaxel. Here, we presented a case of a 49-year-old man with a history of right lung mass proven by biopsy to be a nonsmall cell lung cancer (squamous cell carcinoma) who developed HSR during therapy. In addition to the hypermetabolic primary malignancy, a positron emission tomography/computed tomography (PET/CT) scan showed multiple hypermetabolic skin lesions at several parts of the body. These cutaneous lesions were resolved in the restaging PET/CT scan performed after completion of the six cycles of chemotherapy. This is the first documented case of comparative PET/CT findings of a paclitaxel-induced hypersensitivity
Presentation of genital tuberculosis detected on FDG PET/CT scan resembling a primary gynecologic tumor and metastases
Gastric cancer (GC) is a common cause of cancer-related deaths in the world. In addition to the patient’s clinical history and clinical examination, nuclear medicine tools are required for diagnosis. [18F]FDG PET/CT has been commonly used for cancer patients for staging, restaging, evaluation of treatment response. This study aimed to review the current literature on the role of [18F]FDG PET/CT for GC management
Pulmonary alveolar microlithiasis with low fluorodeoxyglucose accumulation in PET/computed tomography
Pulmonary alveolar microlithiasis (PAM) is an uncommon lung disease characterized by accumulation of intraalveolar calcifications. The disease can be diagnosed based on the radiological findings. We present a 27-year-old women with five-year history of shortness of breath. She was diagnosed with PAM due to the presence of the characteristic chest X-ray and thorax computed tomography (CT) findings. We performed 18F-fluorodeoxyglucose (FDG)-PET/CT imaging in order to detect any evidence of inflamation in the lung before deciding an anti-inflammatory treatment. The lung regions with dense calcifications revealed low FDG uptakes (SUVmax: 2.7) and the lung regions without calcifications showed lower FDG uptakes. No further treatment modality was planned besides inhaler salbutamol. Herein, we discuss this rare entity with literature search
Occipital Hypometabolism on FDG PET/CT Scan in a Child with Hodgkin’s Lymphoma
It is known that Fluorodeoxyglucose (FDG) Positron Emission/Computed Tomography (PET/CT) images may be helpful for evaluation of brain function in newborns. Here we described the fluorine-18 [18-F] FDG PET/CT imaging findings of encephalomalacia due to perinatal asphyxia in a child with refractory Hodgkin’s Lymphoma (HL) who underwent PET/CT scan to stage the primary disease. Prominent hypometabolism was incidentally detected in the occipital regions bilaterally apart from the FDG uptakes in the malign lymphatic infiltrations. This case highlights the potential coexistence of a malignancy and a functional brain disorder
Occipital Hypometabolism on FDG PET/CT Scan in a Child with Hodgkin’s Lymphoma
It is known that Fluorodeoxyglucose (FDG) Positron Emission/Computed Tomography (PET/CT) images may be helpful for evaluation of brain function in newborns. Here we described the fluorine-18 [18-F] FDG PET/CT imaging findings of encephalomalacia due to perinatal asphyxia in a child with refractory Hodgkin’s Lymphoma (HL) who underwent PET/CT scan to stage the primary disease. Prominent hypometabolism was incidentally detected in the occipital regions bilaterally apart from the FDG uptakes in the malign lymphatic infiltrations. This case highlights the potential coexistence of a malignancy and a functional brain disorder
The role of FDG PET/CT in evaluation of mediastinal masses and neurogenic tumors of chest wall
WOS: 000361557500103PubMed ID: 26379916We evaluated the efficiency of FDG PET/CT for the differentiation of malignant from benign mediastinal masses and neurogenic tumors of chest-wall. Methods: The 88 patients with chest wall-mediastinal masses who underwent examination before operation were retrospectively reviewed. Size, CT density (HU mean) and SUVmax of mediastinal and chest wall lesions were determined. Statistical differences of these parameters were compared between groups by Mann-Whitney U test. Receiver-operating characteristic curve (ROC) analysis with respect to SUVmax was performed to determine the best cutoff value for differentiating benign from malignant masses. Results: The overall sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) of PET/CT in detection of malignancy were 90%, 55.17%, 67%, 50.94% and 91.43%, respectively. The SUVmax, HU mean and size were higher in malignant cases (P < 0.05). To distinguish benign and malignant lesions, the cut off value of SUVmax was 4.67. The lesion SUVmax was significantly associated with the lesion size and lesion HU mean values (P < 0.05). The value of SUVmax and HU mean were higher in solid benign lesions than those of cystic benign lesions (P < 0.05). The lesion size was higher in cystic lesions (P = 0.000). The mean SUVmax was significantly higher in invasive thymomas than those of non-invasive forms (P = 0.029). Conclusion: FDG PET/CT may be complementary to conventional imaging methods for the evaluation of mediastinal and chest wall masses. PET/CT may reduce unnecessary invasive investigations for diagnosis in patients with nonavid or low avid FDG lesions. However confirmatory tissue sampling is required to confirm PET positive findings for the definite diagnosis
Risk factors and maximum standardized uptake values within lymph nodes of anthracosis diagnosed by endobronchial ultrasound-guided transbronchial needle aspiration
Background/aim: Enlarged mediastinal lymph nodes can result from serious
etiologies including granulomatous disease, neoplasia, etc., and a rare
condition called anthracosis. The aim of this study was to determine the
incidence of risk factors and the uptake values within the anthracotic
lymph nodes.
Materials and methods: 106 patients who underwent endobronchial
ultrasound transbronchial needle aspiration and were diagnosed as having
anthracosis were analyzed retrospectively. Patients with positive
confirmation by surgical biopsies or a 1-year follow-up period were
enrolled.
Results: 201 lymph nodes were sampled from 106 patients. Subcarinal and
interlobar lymph nodes were the most commonly affected stations (36.8\%
and 34.3\%, respectively). The mean durations of exposure to biomass and
cigarette smoke were 35.5 and 33 years, respectively. The mean maximum
standardized uptake value (SUVmax) within the lymph nodes was 4.76. The
SUVmax of the patients with associated malignancy was 4.19 and the
SUVmax of nonmalignant patients was 5.28. This difference was
statistically significant (P = 0.009).
Conclusion: These findings suggest that anthracosis also affects the
mediastinal and hilar stations; it should be considered in differential
diagnosis in patients with mediastinal and hilar lymphadenopathies with
intense uptake on positron emission tomography scans, especially when
there is a history of exposure to known risk factors
18F-Fdg Pet/Ct Rarely Provides Additional Information Other Than Primary Tumor Detection In Patients With Pulmonary Carcinoid Tumors
Aim: The purpose of this study was to assess the contribution of (18) F-fluorodeoxyglucose (FDG) Positron Emission Tomography (PET)/Computed Tomography (CT) in detection and staging of pulmonary carcinoid tumors. Methods: A total of 22 patients with pulmonary carcinoid tumors (14 typical, 8 atypical) were reviewed in this retrospective study. PET/CT images of all patients were evaluated for primary tumor as well as metastatic regional lymph nodes, bone and other distant metastases. PET/CT positivity of primary tumors was determined by visual interpretation. Tumor size, SUVmax and Hounsfield Unit (HU) values of the tumors were used to test for differences between tumor groups (typical carcinoids and atypical carcinoids). Results: SUVmax of carcinoids ranged from 1.24 to 11.1 (mean, 5.0; median, 2.67). The mean largest diameter of primary tumors was 2.7 1.3 cm, ranging from 1 to 5.5 cm. The overall sensitivity of FDG PET/CT for detection of pulmonary carcinoid tumors was 81.8%. Tumor size, SUVmax and Hounsfield Unit (HU) values of the atypical carcinoids were higher than those for typical carcinoids. However, the results were not statistically meaningful (P > 0.05). The sensitivity and specificity of FDG PET/CT in the detection of mediastinal and hilar lymph nodes metastases were 25% and 83% respectively. One patient had bone metastasis. Conclusion: Although FDG PET/CT can be a useful tool for the detection of pulmonary carcinoid tumors and distant metastasis, it cannot discriminate typical carcinoids from atypical ones and absence of an FDG avid lesion cannot exclude pulmonary carcinoid tumors. Moreover, PET/CT is not a reliable tool in the staging of mediastinal and hilar lymph nodes especially for those patients with typical carcinoids.Wo