12 research outputs found

    Changes in lumbar muscle diffusion tensor indices with age

    Get PDF
    © 2024 The Authors. Published by OUP. This is an open access article available under a Creative Commons licence. The published version can be accessed at the following link on the publisher’s website: https://doi.org/10.1093/bjro/tzae002Objective To investigate differences in diffusion tensor imaging (DTI) parameters and proton density fat fraction (PDFF) in the spinal muscles of younger and older adult males. Methods Twelve younger (19-30 years) and 12 older (61-81years) healthy, physically active male participants underwent T1W, T2W, Dixon and DTI of the lumbar spine. The eigenvalues (λ1, λ2, and λ3), fractional anisotropy (FA), and mean diffusivity (MD) from the DTI together with the PDFF were determined in the multifidus, medial and lateral erector spinae (ESmed, ESlat), and quadratus lumborum (QL) muscles. A two-way ANOVA was used to investigate differences with age and muscle and t-tests for differences in individual muscles with age. Results The ANOVA gave significant differences with age for all DTI parameters and the PDFF (P < .01) and with muscle (P < .01) for all DTI parameters except for λ1 and for the PDFF. The mean of the eigenvalues and MD were lower and the FA higher in the older age group with differences reaching statistical significance for all DTI measures for ESlat and QL (P < .01) but only in ESmed for λ3 and MD (P < .05). Conclusions Differences in DTI parameters of muscle with age result from changes in both in the intra- and extra-cellular space and cannot be uniquely explained in terms of fibre length and diameter. Advances in knowledge Previous studies looking at age have used small groups with uneven age spacing. Our study uses two well defined and separated age groups.Published versio

    The DUNE far detector vertical drift technology. Technical design report

    Get PDF
    DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise. In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered. This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals

    The Middlesex University rehabilitation robot

    Get PDF
    This paper outlines the historical developments of Wheelchair-Mounted Robot Arms (WMRA's) and then focuses on the ongoing research at Middlesex to develop a low-cost aid to daily living for users with high-level quadriplegia. A detailed review is given explaining the design specification. It describes the construction of the robotic device and its control architecture. The prototype robot used several gesture recognition and other input systems. The prototype has been tested on disabled and non-disabled users with positive feedback. They observed that it was easy to use, but issues about speed of operation were resolved after further development. The robot has a payload of greater than 1kg with a maximum reach of 0.7–0.9m. Published by the Taylor &amp; Francis Publishing Group, this publication is one of the only journals to cover the multi-disciplinary area of medical technology research. Currently, research bids are being formulated with the School of Computing Science to continue this researc

    Steganographic Techniques for Hiding Data in SWF Files

    No full text

    Extending the IT service quality measurement framework through a systematic literature review

    Get PDF
    Continuous improvement of service quality results in enhanced customer satisfaction, increased efficiency and maximisation of business value of the service within the company. Decision-making on the course of service quality improvement is based on the current status of the measurable service quality attributes. The aim of the paper is to describe the IT service quality attributes that could be measured to improve IT service quality. We report on a systematic literature review of IT service quality measurement. The review was based on 134 relevant journal articles related to IT service quality management. Of these, 91 articles were selected for analysis. We propose a detailed and comprehensive quality measurement framework for IT services using the results of the systematic literature review to extend previous work. The framework presents six common issue areas with their associated measurement categories, measures, and indicators. IT service providers can choose the measures to satisfy their specific information needs from the proposed IT service quality measurement framework. We conclude that IT service quality improvement efforts could benefit from considering the internal IT service quality attributes from the viewpoint of the value the provided IT service could bring to both the customer and the provider

    The Institute of Archaeology Field Course 2014: The Search for the Lost Hunting Lodge of the Earls of Arundel at Downley, Singleton, West Sussex, UK

    No full text
    This paper discusses research into the area of the medieval and post-medieval deer park, at Downley in West Sussex, which is the focus of the Institute’s current training excavations. The excavations constitute part of a wider project attempting to learn more about the development and function of the park through time. A range of information, which indicated the presence of a substantial lodge building within the park was considered and the 2014 excavations have revealed evidence almost certainly corroborating its presence. The project will continue both on and off site in 2015

    Performance of a modular ton-scale pixel-readout liquid argon time projection chamber

    No full text
    The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations

    Performance of a modular ton-scale pixel-readout liquid argon time projection chamber

    No full text
    International audienceThe Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations

    Performance of a modular ton-scale pixel-readout liquid argon time projection chamber

    No full text
    International audienceThe Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations
    corecore