3,012 research outputs found

    Prognostic value of bcl-2 expression in invasive breast cancer.

    Get PDF
    Expression of the bcl-2 proto-oncogene was studied immunohistochemically in 251 invasive ductal breast carcinomas (median follow-up time 91 months, range 24-186 months) and the results were correlated with clinicopathological data and prognostic variables. Sixty-three (25%) tumours were scored bcl-2 negative and 188 (75%) tumours were bcl-2 positive. No relationship could be observed between bcl-2 status and tumour grade, pTNM staging or menopausal status. A strong positive relationship was demonstrated between bcl-2 immunoreactivity and oestrogen receptor status (P < 0.001) and progesterone receptor status (P < 0.001). No prognostic value was demonstrated for bcl-2 expression on disease-free survival and overall survival in axillary node-negative breast cancer patients. However, in axillary node-positive breast cancer patients multivariate analysis demonstrated absence of bcl-2 expression to be independently related to shortened disease-free survival (P = 0.003) and shortened overall survival (P < 0.001). Our results suggest a potential important role for bcl-2 expression as a modulator of response to adjuvant therapy in breast cancer

    Multiregional Satellite Precipitation Products Evaluation over Complex Terrain

    Get PDF
    An extensive evaluation of nine global-scale high-resolution satellite-based rainfall (SBR) products is performed using a minimum of 6 years (within the period of 2000-13) of reference rainfall data derived from rain gauge networks in nine mountainous regions across the globe. The SBR products are compared to a recently released global reanalysis dataset from the European Centre for Medium-Range Weather Forecasts (ECMWF). The study areas include the eastern Italian Alps, the Swiss Alps, the western Black Sea of Turkey, the French Cévennes, the Peruvian Andes, the Colombian Andes, the Himalayas over Nepal, the Blue Nile in East Africa, Taiwan, and the U.S. Rocky Mountains. Evaluation is performed at annual, monthly, and daily time scales and 0.25° spatial resolution. The SBR datasets are based on the following retrieval algorithms: Tropical Rainfall Measuring Mission Multisatellite Precipitation Analysis (TMPA), the NOAA/Climate Prediction Center morphing technique (CMORPH), Precipitation Estimation from Remotely Sensed Information Using Artificial Neural Networks (PERSIANN), and Global Satellite Mapping of Precipitation (GSMaP). SBR products are categorized into those that include gauge adjustment versus unadjusted. Results show that performance of SBR is highly dependent on the rainfall variability. Many SBR products usually underestimate wet season and overestimate dry season precipitation. The performance of gauge adjustment to the SBR products varies by region and depends greatly on the representativeness of the rain gauge network

    Characterisation of Medipix3 Silicon Detectors in a Charged-Particle Beam

    Get PDF
    While designed primarily for X-ray imaging applications, the Medipix3 ASIC can also be used for charged-particle tracking. In this work, results from a beam test at the CERN SPS with irradiated and non-irradiated sensors are presented and shown to be in agreement with simulation, demonstrating the suitability of the Medipix3 ASIC as a tool for characterising pixel sensors.Comment: 16 pages, 13 figure

    Precision scans of the pixel cell response of double sided 3D pixel detectors to pion and x-ray beams

    Get PDF
    hree-dimensional (3D) silicon sensors offer potential advantages over standard planar sensors for radiation hardness in future high energy physics experiments and reduced charge-sharing for X-ray applications, but may introduce inefficiencies due to the columnar electrodes. These inefficiencies are probed by studying variations in response across a unit pixel cell in a 55Όm pitch double-sided 3D pixel sensor bump bonded to TimePix and Medipix2 readout ASICs. Two complementary characterisation techniques are discussed: the first uses a custom built telescope and a 120GeV pion beam from the Super Proton Synchrotron (SPS) at CERN; the second employs a novel technique to illuminate the sensor with a micro-focused synchrotron X-ray beam at the Diamond Light Source, UK. For a pion beam incident perpendicular to the sensor plane an overall pixel efficiency of 93.0±0.5% is measured. After a 10o rotation of the device the effect of the columnar region becomes negligible and the overall efficiency rises to 99.8±0.5%. The double-sided 3D sensor shows significantly reduced charge sharing to neighbouring pixels compared to the planar device. The charge sharing results obtained from the X-ray beam study of the 3D sensor are shown to agree with a simple simulation in which charge diffusion is neglected. The devices tested are found to be compatible with having a region in which no charge is collected centred on the electrode columns and of radius 7.6±0.6Όm. Charge collection above and below the columnar electrodes in the double-sided 3D sensor is observed

    Performance of the LHCb Vertex Detector Alignment Algorithm determined with Beam Test Data

    Full text link
    LHCb is the dedicated heavy flavour experiment at the Large Hadron Collider at CERN. The partially assembled silicon vertex locator (VELO) of the LHCb experiment has been tested in a beam test. The data from this beam test have been used to determine the performance of the VELO alignment algorithm. The relative alignment of the two silicon sensors in a module and the relative alignment of the modules has been extracted. This alignment is shown to be accurate at a level of approximately 2 micron and 0.1 mrad for translations and rotations, respectively in the plane of the sensors. A single hit precision at normal track incidence of about 10 micron is obtained for the sensors. The alignment of the system is shown to be stable at better than the 10 micron level under air to vacuum pressure changes and mechanical movements of the assembled system.Comment: accepted for publication in NIM

    First results from the NA60 experiment at CERN

    Full text link
    Since 1986, several heavy ion experiments have studied some signatures of the formation of the quark-gluon plasma and a few exciting results have been found. However, some important questions are still unanswered and require new measurements. The NA60 experiment, with a new detector concept that vastly improves dimuon detection in proton-nucleus and heavy-ion collisions, studies several of those open questions, including the production of open charm. This paper presents the experiment and some first results from data collected in 2002.Comment: Paper presented at the XXXVIII Rencontres de Moriond, QCD and High Energy Hadronic Interactions, Les Arcs, March 22-29, 2003. 4 pages, 6 figure

    Timing performance of the LHCb VELO Timepix3 Telescope

    Full text link
    We performed a detailed study of the timing performance of the LHCb VELO Timepix3 Telescope with a 180 GeV/c mixed hadron beam at the CERN SPS. A twofold method was developed to improve the resolution of single-plane time measurements, resulting in a more precise overall track time measurement. The first step uses spatial information of reconstructed tracks in combination with the measured signal charge in the sensor to correct for a mixture of different effects: variations in charge carrier drift time; variations in signal induction, which are the result of a non-uniform weighting field in the pixels; and lastly, timewalk in the analog front-end. The second step corrects for systematic timing offsets in Timepix3 that vary from -2 ns to 2 ns. By applying this method, we improved the track time resolution from 438 ± \,\pm\,16 ps to 276 ± \,\pm\,4 ps

    First results from NA60 on low mass muon pair production in In-In collisions at 158 GeV/nucleon

    Full text link
    The NA60 experiment at the CERN SPS studies dimuon production in proton-nucleus and nucleus-nucleus collisions. The combined information from a novel vertex telescope made of radiation-tolerant silicon pixel detectors and from the muon spectrometer previously used in NA50 allows for a precise measurement of the muon vertex and a much improved dimuon mass resolution. We report on first results from the data taken for Indium-Indium collisions at 158 AGeV/nucleon in 2003, concentrating on a subsample of about 370 000 muon pairs in the mass range <1.2<1.2 GeV/c2c^{2}. The light vector mesons ω\omega and ϕ\phi are completely resolved, with a mass resolution of about 23 MeV/c2c^{2} at the ϕ\phi. The transverse momentum spectra of the ϕ\phi are measured over the continuous range 0<pT<2.50<p_{\rm T}<2.5 GeV/c; the inverse slope parameter of the spectra is found to increase with centrality, with an average value of T=252±3T=252\pm3 MeV.Comment: 9 pages, 6 figures. Plenary talk, SQM2004 conference, Cape Town, South Africa 15-20 September, 2004. To be published in Journal of Physics G: Nuclear and Particle Physic

    Radiation damage in the LHCb vertex locator

    Get PDF
    The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have been exposed to a range of fluences up to a maximum value of approximately 45 × 1012 1 MeV neutron equivalent (1 MeV neq). At the operational sensor temperature of approximately −7 °C, the average rate of sensor current increase is 18 ÎŒA per fb−1, in excellent agreement with predictions. The silicon effective bandgap has been determined using current versus temperature scan data after irradiation, with an average value of Eg = 1.16±0.03±0.04 eV obtained. The first observation of n+-on-n sensor type inversion at the LHC has been made, occurring at a fluence of around 15 × 1012 of 1 MeV neq. The only n+-on-p sensors in use at the LHC have also been studied. With an initial fluence of approximately 3 × 1012 1 MeV neq, a decrease in the Effective Depletion Voltage (EDV) of around 25 V is observed. Following this initial decrease, the EDV increases at a comparable rate to the type inverted n+-on-n type sensors, with rates of (1.43±0.16) × 10−12 V/ 1 MeV neq and (1.35±0.25) × 10−12 V/ 1 MeV neq measured for n+-on-p and n+-on-n type sensors, respectively. A reduction in the charge collection efficiency due to an unexpected effect involving the second metal layer readout lines is observed

    In transition: current health challenges and priorities in Sudan

    Get PDF
    A recent symposium and workshop in Khartoum, the capital of the Republic of Sudan, brought together broad expertise from three universities to address the current burden of communicable and non-communicable diseases facing the Sudanese healthcare system. These meetings identified common challenges that impact the burden of diseases in the country, most notably gaps in data and infrastructure which are essential to inform and deliver effective interventions. Non-communicable diseases, including obesity, type 2 diabetes, renal disease and cancer are increasing dramatically, contributing to multimorbidity. At the same time, progress against communicable diseases has been slow, and the burden of chronic and endemic infections remains considerable, with parasitic diseases (such as malaria, leishmaniasis and schistosomiasis) causing substantial morbidity and mortality. Antimicrobial resistance has become a major threat throughout the healthcare system, with an emerging impact on maternal, neonatal, and paediatric populations. Meanwhile, malnutrition, micronutrient deficiency, and poor perinatal outcomes remain common and contribute to a lifelong burden of disease. These challenges echo the UN sustainable development goals and concentrating on them in a unified strategy will be necessary to address the national burden of disease. At a time when the country is going through societal and political transition, we draw focus on the country and the need for resolution of its healthcare needs
    • 

    corecore