111 research outputs found

    Molecular Clusters in Mesoporous Materials as Precursors to Nanoparticles of a New Lacunar Ternary Compound PdxMoyP

    Get PDF
    Bimetallic clusters of composition Pd2Mo2(g5-C5H5)2(l3-CO)2(l2-CO)4 (PR3)2 (R = ethyl or phenyl) were incorporated by impregnation from solution into two different silica matrices, amorphous xerogels and ordered SBA-15, and a study of their thermal decomposition under a reducing atmosphere is reported. With both matrices, a suitable thermal treatment afforded nanoparticles of a new bimetallic phosphide. Although nanoparticles of composition PdxMoyP, isostructural with Mo3P, were formed in both matrices, they were more uniformly distributed in the SBA-15 framework and showed a narrower size distribution. The samples have been characterized by powder XRD, chemical analysis, FT-IR spectroscopy, TEM and electron tomography (3D TEM)

    Observation of a single protein by ultrafast X-ray diffraction

    Get PDF
    The idea of using ultrashort X-ray pulses to obtain images of single proteins frozen in time has fascinated and inspired many. It was one of the arguments for building X-ray free-electron lasers. According to theory1, the extremely intense pulses provide sufficient signal to dispense with using crystals as an amplifier, and the ultrashort pulse duration permits capturing the diffraction data before the sample inevitably explodes2. This was first demonstrated on biological samples a decade ago on the giant mimivirus3. Since then a large collaboration4 has been pushing the limit of the smallest sample that can be imaged5,6. The ability to capture snapshots on the timescale of atomic vibrations, while keeping the sample at room temperature, may allow probing the entire conformational phase space of macromolecules. Here we show the first observation of an X-ray diffraction pattern from a single protein, that of Escherichia coli GroEL which at 14 nm in diameter7 is the smallest biological sample ever imaged by X-rays, and demonstrate that the concept of diffraction before destruction extends to single proteins. From the pattern, it is possible to determine the approximate orientation of the protein. Our experiment demonstrates the feasibility of ultrafast imaging of single proteins, opening the way to single-molecule time-resolved studies on the femtosecond timescale

    Test beam performance measurements for the Phase I upgrade of the CMS pixel detector

    Get PDF
    A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is (99.95 ± 0.05) %, while the intrinsic spatial resolutions are (4.80 ± 0.25) μm and (7.99 ± 0.21) μm along the 100 μm and 150 μm pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.Peer reviewe
    • …
    corecore