125 research outputs found

    The year 2017 in the European Heart Journal-Cardiovascular Imaging: Part I.

    Get PDF
    The European Heart Journal - Cardiovascular Imaging was launched in 2012. It has gained an impressive impact factor of 8.336 during its first 6 years and is now established as one of the top 10 cardiovascular journals in the world and the most important cardiovascular imaging journal in Europe. The most important studies published in the journal in 2017 will be highlighted in two reports. Part I will focus on studies about myocardial function, coronary artery disease and myocardial ischaemia, and emerging techniques and applications in cardiovascular imaging, whereas Part II will focus on valvular heart disease, heart failure, cardiomyopathies, and congenital heart disease

    Classification of human coronary atherosclerotic plaques with T1, T2 and Ultrashort TE MRI

    Get PDF
    Multicontrast MRI with T1, T2 and Ultrashort TE (UTE) sequences is used to image atherosclerotic plaque in human coronary arteries. MRI classification of the plaques is compared with their histological classification and found to correlate extremely well. The addition of UTE MRI adds significant value to the imaging of human coronary artery plaque by MRI

    Preoperative Chest Computed Tomography Screening for Coronavirus Disease 2019 in Asymptomatic Patients Undergoing Cardiac Surgery

    Get PDF
    Due to the outbreak of Severe Acute Respiratory Syndrome coronavirus (SARS-Cov-2), an efficient COVID-19 screening strategy is required for patients undergoing cardiac surgery. The objective of this prospective observational study was to evaluate the role of preoperative computed tomography (CT) screening for COVID-19 in a population of COVID-19 asymptomatic patients scheduled for cardiac surgery. Between the 29th of March and the 26th of May 2020, patients asymptomatic for COVID-19 underwent a CT-scan the day before surgery, with reverse-transcriptase polymerase-chain reaction (RT-PCR) reserved for abnormal scan results. The primary endpoint was the prevalence of abnormal scans, which was evaluated using the CO-RADS score, a COVID-19 specific grading system. In a secondary analysis, the rate of abnormal scans was compared between the screening cohort and matched historical controls who underwent routine preoperative CT-screening prior to the SARS-Cov-2 outbreak. Of the 109 patients that underwent CT-screening, an abnormal scan result was observed in 7.3% (95% confidence interval: 3.2–14.0%). One patient, with a normal screening CT, was tested positive for COVID-19, with the first positive RT-PCR on the ninth day after surgery. A rate of preoperative CT-scan abnormalities of 8% (n = 8) was found in the unexposed historical controls (P &gt; 0.999). In asymptomatic patients undergoing cardiac surgery, preoperative screening for COVID-19 using computed tomography will identify pulmonary abnormalities in a small percentage of patients that do not seem to have COVID-19. Depending on the prevalence of COVID-19, this results in an unfavorable positive predictive value of CT screening. Care should be taken when considering CT as a screening tool prior to cardiac surgery.</p

    Left ventricular remodeling following myocardial infarction revealed with a quantitative diffusion MRI tractography framework

    Get PDF
    A cardiac-tailored framework for 3D Diffusion Tensor MRI tractography is developed and used to characterize myofiber architecture in normal and remodeled myocardium. We show that myofibers in the subepicardium of the remote infarct zone become less oblique (more circumferential) as the heart dilates and remodels. This fiber realignment may play an important role in the loss of contractile function in the remote zone over time

    Left atrial appendage size is a marker of atrial fibrillation recurrence after radiofrequency catheter ablation in patients with persistent atrial fibrillation

    Get PDF
    Introduction There are no consistently confirmed predictors of atrial fibrillation (AF) recurrence after catheter ablation. Therefore, we aimed to study whether left atrial appendage volume (LAAV) and function influence the long-term recurrence of AF after catheter ablation, depending on AF type. Methods AF patients who underwent point-by-point radiofrequency catheter ablation after cardiac computed tomography (CT) were included in this analysis. LAAV and LAA orifice area were measured by CT. Uni- and multivariable Cox proportional hazard regression models were performed to determine the predictors of AF recurrence. Results In total, 561 AF patients (61.9 +/- 10.2 years, 34.9% females) were included in the study. Recurrence of AF was detected in 40.8% of the cases (34.6% in patients with paroxysmal and 53.5% in those with persistent AF) with a median recurrence-free time of 22.7 (9.3-43.1) months. Patients with persistent AF had significantly higher body surface area-indexed LAV, LAAV, and LAA orifice area and lower LAA flow velocity, than those with paroxysmal AF. After adjustment left ventricular ejection fraction (LVEF) <50% (HR = 2.17; 95% CI = 1.38-3.43; p < .001) and LAAV (HR = 1.06; 95% CI = 1.01-1.12; p = .029) were independently associated with AF recurrence in persistent AF, while no independent predictors could be identified in paroxysmal AF. Conclusion The current study demonstrates that beyond left ventricular systolic dysfunction, LAA enlargement is associated with higher rate of AF recurrence after catheter ablation in persistent AF, but not in patients with paroxysmal AF.Cardiovascular Aspects of Radiolog

    Dual-Energy X-Ray Absorptiometry for Quantification of Visceral Fat

    Get PDF
    Obesity is the major risk factor for metabolic syndrome and through it diabetes as well as cardiovascular disease. Visceral fat (VF) rather than subcutaneous fat (SF) is the major predictor of adverse events. Currently, the reference standard for measuring VF is abdominal X-ray computed tomography (CT) or magnetic resonance imaging (MRI), requiring highly used clinical equipment. Dual-energy X-ray absorptiometry (DXA) can accurately measure body composition with high-precision, low X-ray exposure, and short-scanning time. The purpose of this study was to validate a new fully automated method whereby abdominal VF can be measured by DXA. Furthermore, we explored the association between DXA-derived abdominal VF and several other indices for obesity: BMI, waist circumference, waist-to-hip ratio, and DXA-derived total abdominal fat (AF), and SF. We studied 124 adult men and women, aged 18–90 years, representing a wide range of BMI values (18.5–40 kg/m2) measured with both DXA and CT in a fasting state within a one hour interval. The coefficient of determination (r2) for regression of CT on DXA values was 0.959 for females, 0.949 for males, and 0.957 combined. The 95% confidence interval for r was 0.968 to 0.985 for the combined data. The 95% confidence interval for the mean of the differences between CT and DXA VF volume was −96.0 to −16.3 cm3. Bland–Altman bias was +67 cm3 for females and +43 cm3 for males. The 95% limits of agreement were −339 to +472 cm3 for females and −379 to +465 cm3 for males. Combined, the bias was +56 cm3 with 95% limits of agreement of −355 to +468 cm3. The correlations between DXA-derived VF and BMI, waist circumference, waist-to-hip ratio, and DXA-derived AF and SF ranged from poor to modest. We conclude that DXA can measure abdominal VF precisely in both men and women. This simple noninvasive method with virtually no radiation can therefore be used to measure VF in individual patients and help define diabetes and cardiovascular risk

    International impact of COVID-19 on the diagnosis of heart disease

    Get PDF
    Background: The coronavirus disease 2019 (COVID-19) pandemic has adversely affected diagnosis and treatment of noncommunicable diseases. Its effects on delivery of diagnostic care for cardiovascular disease, which remains the leading cause of death worldwide, have not been quantified. Objectives: The study sought to assess COVID-19's impact on global cardiovascular diagnostic procedural volumes and safety practices. Methods: The International Atomic Energy Agency conducted a worldwide survey assessing alterations in cardiovascular procedure volumes and safety practices resulting from COVID-19. Noninvasive and invasive cardiac testing volumes were obtained from participating sites for March and April 2020 and compared with those from March 2019. Availability of personal protective equipment and pandemic-related testing practice changes were ascertained. Results: Surveys were submitted from 909 inpatient and outpatient centers performing cardiac diagnostic procedures, in 108 countries. Procedure volumes decreased 42% from March 2019 to March 2020, and 64% from March 2019 to April 2020. Transthoracic echocardiography decreased by 59%, transesophageal echocardiography 76%, and stress tests 78%, which varied between stress modalities. Coronary angiography (invasive or computed tomography) decreased 55% (p < 0.001 for each procedure). In multivariable regression, significantly greater reduction in procedures occurred for centers in countries with lower gross domestic product. Location in a low-income and lower–middle-income country was associated with an additional 22% reduction in cardiac procedures and less availability of personal protective equipment and telehealth. Conclusions: COVID-19 was associated with a significant and abrupt reduction in cardiovascular diagnostic testing across the globe, especially affecting the world's economically challenged. Further study of cardiovascular outcomes and COVID-19–related changes in care delivery is warranted
    corecore