741 research outputs found
Slow and Smooth: A Bayesian Theory for the Combination of Local Motion Signals in Human Vision
In order to estimate the motion of an object, the visual system needs to combine multiple local measurements, each of which carries some degree of ambiguity. We present a model of motion perception whereby measurements from different image regions are combined according to a Bayesian estimator --- the estimated motion maximizes the posterior probability assuming a prior favoring slow and smooth velocities. In reviewing a large number of previously published phenomena we find that the Bayesian estimator predicts a wide range of psychophysical results. This suggests that the seemingly complex set of illusions arise from a single computational strategy that is optimal under reasonable assumptions
Does Perceptual Belongingness Affect Lightness Constancy?
Scientists have shown that two equal grey patches may differ in lightness when belonging to different reflecting surfaces. We extend this investigation to the constancy domain. In a CRT simulation of a bipartite field of illumination, we manipulated the arrangement of twelve patches: six squares and six diamonds. Patches of the same shape could be placed: (i) all within the same illumination field; or (ii) forming a row across the illumination fields. Furthermore, we manipulated proximity between the innermost patches and the illumination edge. The patches could be (i) touching (forming an X-junction); or (ii) not touching (not forming an X-junction). Observers were asked to perform a lightness match between two additional patches, one illuminated and the other in shadow. We found better lightness constancy when the patches of the same shape formed a row across the fields, with no effect of X-junctions
Millimeter and Submillimeter Survey of the R Corona Australis Region
Using a combination of data from the Antarctic Submillimeter Telescope and
Remote Observatory (AST/RO), the Arizona Radio Observatory Kitt Peak 12m
telescope and the Arizona Radio Observatory 10m Heinrich Hertz Telescope, we
have studied the most active part of the R CrA molecular cloud in multiple
transitions of Carbon Monoxide, HCO and 870\micron continuum emission.
Since R CrA is nearby (130 pc), we are able to obtain physical spatial
resolution as high as 0.01pc over an area of 0.16 pc, with velocity
resolution finer than 1 km/s. Mass estimates of the protostar driving the
mm-wave emission derived from HCO, dust continuum emission and kinematic
techniques point to a young, deeply embedded protostar of 0.5-0.75
M, with a gaseous envelope of similar mass. A molecular outflow is
driven by this source that also contains at least 0.8 M of molecular
gas with 0.5 L of mechanical luminosity. HCO lines show the
kinematic signature of infall motions as well as bulk rotation. The source is
most likely a Class 0 protostellar object not yet visible at near-IR
wavelengths. With the combination of spatial and spectral resolution in our
data set, we are able to disentangle the effects of infall, rotation and
outflow towards this young object.Comment: 29 pages, 9 figures. Accepted for publication in the Astrophysical
Journa
Provably scale-covariant networks from oriented quasi quadrature measures in cascade
This article presents a continuous model for hierarchical networks based on a
combination of mathematically derived models of receptive fields and
biologically inspired computations. Based on a functional model of complex
cells in terms of an oriented quasi quadrature combination of first- and
second-order directional Gaussian derivatives, we couple such primitive
computations in cascade over combinatorial expansions over image orientations.
Scale-space properties of the computational primitives are analysed and it is
shown that the resulting representation allows for provable scale and rotation
covariance. A prototype application to texture analysis is developed and it is
demonstrated that a simplified mean-reduced representation of the resulting
QuasiQuadNet leads to promising experimental results on three texture datasets.Comment: 12 pages, 3 figures, 1 tabl
Local biases drive, but do not determine, the perception of illusory trajectories
When a dot moves horizontally across a set of tilted lines of alternating orientations, the dot appears to be moving up and down along its trajectory. This perceptual phenomenon, known as the slalom illusion, reveals a mismatch between the veridical motion signals and the subjective percept of the motion trajectory, which has not been comprehensively explained. In the present study, we investigated the empirical boundaries of the slalom illusion using psychophysical methods. The phenomenon was found to occur both under conditions of smooth pursuit eye movements and constant fixation, and to be consistently amplified by intermittently occluding the dot trajectory. When the motion direction of the dot was not constant, however, the stimulus display did not elicit the expected illusory percept. These findings confirm that a local bias towards perpendicularity at the intersection points between the dot trajectory and the tilted lines cause the illusion, but also highlight that higher-level cortical processes are involved in interpreting and amplifying the biased local motion signals into a global illusion of trajectory perception
Local biases drive, but do not determine, the perception of illusory trajectories
When a dot moves horizontally across a set of tilted lines of alternating orientations, the dot appears to be moving up and down along its trajectory. This perceptual phenomenon, known as the slalom illusion, reveals a mismatch between the veridical motion signals and the subjective percept of the motion trajectory, which has not been comprehensively explained. In the present study, we investigated the empirical boundaries of the slalom illusion using psychophysical methods. The phenomenon was found to occur both under conditions of smooth pursuit eye movements and constant fixation, and to be consistently amplified by intermittently occluding the dot trajectory. When the motion direction of the dot was not constant, however, the stimulus display did not elicit the expected illusory percept. These findings confirm that a local bias towards perpendicularity at the intersection points between the dot trajectory and the tilted lines cause the illusion, but also highlight that higher-level cortical processes are involved in interpreting and amplifying the biased local motion signals into a global illusion of trajectory perception
IND-Enabling Studies for a Clinical Trial to Genetically Program a Persistent Cancer-Targeted Immune System
PURPOSE:
To improve persistence of adoptively transferred T-cell receptor (TCR)-engineered T cells and durable clinical responses, we designed a clinical trial to transplant genetically-modified hematopoietic stem cells (HSCs) together with adoptive cell transfer of T cells both engineered to express an NY-ESO-1 TCR. Here, we report the preclinical studies performed to enable an investigational new drug (IND) application.
EXPERIMENTAL DESIGN:
HSCs transduced with a lentiviral vector expressing NY-ESO-1 TCR and the PET reporter/suicide gene HSV1-sr39TK and T cells transduced with a retroviral vector expressing NY-ESO-1 TCR were coadministered to myelodepleted HLA-A2/Kb mice within a formal Good Laboratory Practice (GLP)-compliant study to demonstrate safety, persistence, and HSC differentiation into all blood lineages. Non-GLP experiments included assessment of transgene immunogenicity and in vitro viral insertion safety studies. Furthermore, Good Manufacturing Practice (GMP)-compliant cell production qualification runs were performed to establish the manufacturing protocols for clinical use.
RESULTS:
TCR genetically modified and ex vivo-cultured HSCs differentiated into all blood subsets in vivo after HSC transplantation, and coadministration of TCR-transduced T cells did not result in increased toxicity. The expression of NY-ESO-1 TCR and sr39TK transgenes did not have a detrimental effect on gene-modified HSC's differentiation to all blood cell lineages. There was no evidence of genotoxicity induced by the lentiviral vector. GMP batches of clinical-grade transgenic cells produced during qualification runs had adequate stability and functionality.
CONCLUSIONS:
Coadministration of HSCs and T cells expressing an NY-ESO-1 TCR is safe in preclinical models. The results presented in this article led to the FDA approval of IND 17471
The detection of temporally defined objects does not require focused attention.
Perceptual grouping is crucial to distinguish objects from their background. Recent studies have shown that observers can detect an object that does not have any unique qualities other than unique temporal properties. A crucial question is whether focused attention is needed for this type of grouping. In two visual search experiments, we show that searching for an object defined by temporal grouping can occur in parallel. These findings suggest that focused attention is not needed for temporal grouping to occur. It is proposed that temporal grouping may occur because the neurons representing the changing object elements adopt firing frequencies that cause the visual system to bind these elements together without the need for focused attention. © 2008 The Experimental Psychology Society
- …