169 research outputs found

    Development of a novel system for linear displacement sensor calibration

    Get PDF
    This paper presents the development of semi-autonomous metrological devices, capable of calibrating variety of linear displacement sensors, like Linear Variable Differential Transformers (LVDT), string potentiometers, laser displacement sensors and other. Data acquisition equipment that could be used for measuring objects of various shapes and sizes are already available; however, devices specifically tailored for the calibration of displacement sensors are not currently offered. Advantages of this new technology, that we are investigating and developing, include reduction of time, costs and human resources required to perform calibration. In addition to that, the advantages of an affordable calibration device will allow calibrations to be carried out internally, as opposed to outsourcing to dedicated facilities. The scope of the project encompasses research into the device's compliance with ISO/IEC 17025 to obtain NATA accreditation, research into design, and selection of material and manufacturing processes to ensure an acceptable measurement of uncertainty is achievable across all varieties of linear displacement sensors. The sensors are used to measure suspension displacement, steered angle and various other geometries on vehicles and test equipment. Outcomes of this research project offer experimental evidence that proves the feasibility of developing and manufacturing devices that produce an acceptable uncertainty that meets testing standards requirements at a fraction of the cost of comparable measuring devices

    Morphometrical features of left atrial appendage in the AF patients subjected to left atrial appendage closure

    Get PDF
    Background: This study aimed to evaluate the morphometrical features of left atrial appendage (LAA) in patients with atrial fibrillation, subjected to left atrial appendage percutaneous closure (LARIAT) for stroke prevention. Materials and methods: Computed tomography (CT) scans of 51 patients with atrial fibrillation subjected to LARIAT procedure were comparatively evaluated with 50 patients with sinus rhythm (control group). Three-dimensional (3D) reconstructions were created using volume-rendering for evaluation. Results: No differences were found in LAA types of distribution (cauliflower: 25.5 vs. 34.0%, chicken wing: 45.1 vs. 46.0%, windsock: 29.4 vs. 20.0%, all p>0.05) between groups. However, the study group was characterized by LAAs with a lower number of lobes. The LAA orifice anteroposterior and transverse diameters (19.3±4.12 vs. 17.2±4.0mm, p=0.01 and 25.1±5.1 vs. 20.5±4.4mm, p=0.001), orifice area (387.2±133.9 vs. 327.1±128.3mm2, p=0.02) and orifice perimeter (70.2±12.5 vs. 61.2±11.6mm, p=0.04) was significantly larger in atrial fibrillation patients. More oval LAA orifices was found in atrial fibrillation group (94.0 vs. 70.4%, p=0.001). No statistically significant differences were found in LAA body length (47.4±15.4 vs. 43.7±10.9mm, p=0.17), body width (24.7±5.6 vs. 24.4±5.8mm, p=0.81), and chamber depth (17.7±3.5 vs. 16.5±3.8mm, p=0.11). Calculated LAA ejection fraction was significantly lower in study group compared to healthy patients (16.4±14.9 vs. 48.2±12.9%, p=0.001). Conclusions: Important morphometrical differences in LAA orifice have been found, which was significantly larger and more oval in patients with atrial fibrillation compared to healthy controls. Although no difference in LAA body type and size was observed; the LAA ejection fraction was significantly lower in atrial fibrillation rhythm patients

    Evaluating assumptions of scales for subjective assessment of thermal environments – Do laypersons perceive them the way, we researchers believe?

    Get PDF
    International audienc

    Ovarian carcinoma associated with pregnancy: A clinicopathologic analysis of 23 cases and review of the literature

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aim of this study was to analyze and describe cases of ovarian cancer in pregnant women treated at our center and to review the literature concerned, and to discuss the rationale for therapy.</p> <p>Methods</p> <p>Twenty-Three patients of ovarian malignancies during pregnancy were treated at Vali- Asr Hospital between 1991 and 2002. Data on treatment and follow-up were evaluated.</p> <p>Results</p> <p>The incidence of ovarian carcinoma associated with pregnancy in our series was 0.083/1000 deliveries. Eleven (47.8%) were found with ovarian malignant germ cell tumors, five (21.7%) with low malignant potential tumors, four (17.4%) with invasive epithelial tumors, and three (13%) with sex cord stromal tumors. Seventeen (73.9%) of the patients were diagnosed in stage I and had complete remission. Five of the six in advanced stage died. The mean follow-up was 36.3 months. The prognosis was significantly related with stage and histological type (<it>P </it>< 0.05). Sixteen healthy live babies were recorded in this group, and two premature newborn died of respiratory distress syndrome. Chemotherapy was administered to 44% of the patients, in two cases during pregnancy. Overall survival at 5 years was 61%. In most of case conservative surgical treatment could be performed with adequate staging and debulking.</p> <p>Conclusion</p> <p>Early finding of ascitis by ultrasound and persistent large ovarian mass during pregnancy may be related to malignancy and advanced stage. Pregnant women in advanced stage of ovarian cancer seem to have poor prognosis.</p

    Involvement of Complexin 2 in Docking, Locking and Unlocking of Different SNARE Complexes during Sperm Capacitation and Induced Acrosomal Exocytosis

    Get PDF
    Acrosomal exocytosis (AE) is an intracellular multipoint fusion reaction of the sperm plasma membrane (PM) with the outer acrosomal membrane (OAM). This unique exocytotic event enables the penetration of the sperm through the zona pellucida of the oocyte. We previously observed a stable docking of OAM to the PM brought about by the formation of the trans-SNARE complex (syntaxin 1B, SNAP 23 and VAMP 3). By using electron microscopy, immunochemistry and immunofluorescence techniques in combination with functional studies and proteomic approaches, we here demonstrate that calcium ionophore-induced AE results in the formation of unilamellar hybrid membrane vesicles containing a mixture of components originating from the two fused membranes. These mixed vesicles (MV) do not contain the earlier reported trimeric SNARE complex but instead possess a novel trimeric SNARE complex that contained syntaxin 3, SNAP 23 and VAMP 2, with an additional SNARE interacting protein, complexin 2. Our data indicate that the earlier reported raft and capacitation-dependent docking phenomenon between the PM and OAM allows a specific rearrangement of molecules between the two docked membranes and is involved in (1) recruiting SNAREs and complexin 2 in the newly formed lipid-ordered microdomains, (2) the assembly of a fusion-driving SNARE complex which executes Ca2+-dependent AE, (3) the disassembly of the earlier reported docking SNARE complex, (4) the recruitment of secondary zona binding proteins at the zona interacting sperm surface. The possibility to study separate and dynamic interactions between SNARE proteins, complexin and Ca2+ which are all involved in AE make sperm an ideal model for studying exocytosis

    The Scales Project, a cross-national dataset on the interpretation of thermal perception scales

    Get PDF
    Thermal discomfort is one of the main triggers for occupants’ interactions with components of the built environment such as adjustments of thermostats and/or opening windows and strongly related to the energy use in buildings. Understanding causes for thermal (dis-)comfort is crucial for design and operation of any type of building. The assessment of human thermal perception through rating scales, for example in post-occupancy studies, has been applied for several decades; however, long-existing assumptions related to these rating scales had been questioned by several researchers. The aim of this study was to gain deeper knowledge on contextual influences on the interpretation of thermal perception scales and their verbal anchors by survey participants. A questionnaire was designed and consequently applied in 21 language versions. These surveys were conducted in 57 cities in 30 countries resulting in a dataset containing responses from 8225 participants. The database offers potential for further analysis in the areas of building design and operation, psycho-physical relationships between human perception and the built environment, and linguistic analyses
    • …
    corecore