295 research outputs found

    Band-Limited Coronagraphs using a halftone-dot process: II. Advances and laboratory results for arbitrary telescope apertures

    Full text link
    The band-limited coronagraph is a nearly ideal concept that theoretically enables perfect cancellation of all the light of an on-axis source. Over the past years, several prototypes have been developed and tested in the laboratory, and more emphasis is now on developing optimal technologies that can efficiently deliver the expected high-contrast levels of such a concept. Following the development of an early near-IR demonstrator, we present and discuss the results of a second-generation prototype using halftone-dot technology. We report improvement in the accuracy of the control of the local transmission of the manufactured prototype, which was measured to be less than 1%. This advanced H-band band-limited device demonstrated excellent contrast levels in the laboratory, down to 10-6 at farther angular separations than 3 lambda/D over 24% spectral bandwidth. These performances outperform the ones of our former prototype by more than an order of magnitude and confirm the maturity of the manufacturing process. Current and next generation high-contrast instruments can directly benefit from such capabilities. In this context, we experimentally examine the ability of the band-limited coronagraph to withstand various complex telescope apertures.Comment: Accepted in ApJ - under pres

    Line Emission from an Accretion Disk around a Black hole: Effects of Disk Structure

    Get PDF
    The observed iron K-alpha fluorescence lines in Seyfert-1 galaxies provide strong evidence for an accretion disk near a supermassive black hole as a source of the line emission. These lines serve as powerful probes for examining the structure of inner regions of accretion disks. Previous studies of line emission have considered geometrically thin disks only, where the gas moves along geodesics in the equatorial plane of a black hole. Here we extend this work to consider effects on line profiles from finite disk thickness, radial accretion flow and turbulence. We adopt the Novikov and Thorne (1973) solution, and find that within this framework, turbulent broadening is the dominant new effect. The most prominent change in the skewed, double-horned line profiles is a substantial reduction in the maximum flux at both red and blue peaks. The effect is most pronounced when the inclination angle is large, and when the accretion rate is high. Thus, the effects discussed here may be important for future detailed modeling of high quality observational data.Comment: 21 pages including 8 figures; LaTeX; ApJ format; accepted by ApJ; short results of this paper appeared before as a conference proceedings (astro-ph/9711214

    Characterization and Compensation of the Residual Chirp in a Mach-Zehnder-Type Electro-Optical Intensity Modulator

    Full text link
    We utilize various techniques to characterize the residual phase modulation of a fiber-based Mach-Zehnder electro-optical intensity modulator. A heterodyne technique is used to directly measure the phase change due to a given change in intensity, thereby determining the chirp parameter of the device. This chirp parameter is also measured by examining the ratio of sidebands for sinusoidal amplitude modulation. Finally, the frequency chirp caused by an intensity pulse on the nanosecond time scale is measured via the heterodyne signal. We show that this chirp can be largely compensated with a separate phase modulator. The various measurements of the chirp parameter are in reasonable agreement.Comment: 11 pages, 6 figure

    Design, analysis and test of a microdots apodizer for the Apodized Pupil Lyot Coronagraph

    Full text link
    Coronagraphic techniques are required to detect exoplanets with future Extremely Large Telescopes. One concept, the Apodized Pupil Lyot Coronagraph (APLC), is combining an apodizer in the entrance aperture and a Lyot opaque mask in the focal plane. This paper presents the manufacturing and tests of a microdots apodizer optimized for the near IR. The intent of this work is to demonstrate the feasibility and performance of binary apodizers for the APLC. This study is also relevant for any coronagraph using amplitude pupil apodization. A binary apodizer has been designed using a halftone dot process, where the binary array of pixels with either 0% or 100% transmission is calculated to fit the required continuous transmission, i.e. local transmission control is obtained by varying the relative density of the opaque and transparent pixels. An error diffusion algorithm was used to optimize the distribution of pixels that best approximates the required field transmission. The prototype was tested with a coronagraphic setup in the near IR. The transmission profile of the prototype agrees with the theoretical shape within 3% and is achromatic. The observed apodized and coronagraphic images are consistent with theory. However, binary apodizers introduce high frequency noise that is a function of the pixel size. Numerical simulations were used to specify pixel size in order to minimize this effect, and validated by experiment. This paper demonstrates that binary apodizers are well suited for being used in high contrast imaging coronagraphs. The correct choice of pixel size is important and must be adressed considering the scientific field of view.Comment: A&A accepted, 8 page

    Characteristic QSO Accretion Disk Temperatures from Spectroscopic Continuum Variability

    Full text link
    Using Sloan Digital Sky Survey (SDSS) quasar spectra taken at multiple epochs, we find that the composite flux density differences in the rest frame wavelength range 1300-6000 AA can be fit by a standard thermal accretion disk model where the accretion rate has changed from one epoch to the next (without considering additional continuum emission components). The fit to the composite residual has two free parameters: a normalizing constant and the average characteristic temperature Tˉ\bar{T}^*. In turn the characteristic temperature is dependent on the ratio of the mass accretion rate to the square of the black hole mass. We therefore conclude that most of the UV/optical variability may be due to processes involving the disk, and thus that a significant fraction of the UV/optical spectrum may come directly from the disk.Comment: 31 pages, 8 figure

    Implementation of quantum search algorithm using classical Fourier optics

    Get PDF
    We report on an experiment on Grover's quantum search algorithm showing that {\em classical waves} can search a NN-item database as efficiently as quantum mechanics can. The transverse beam profile of a short laser pulse is processed iteratively as the pulse bounces back and forth between two mirrors. We directly observe the sought item being found in N\sim\sqrt{N} iterations, in the form of a growing intensity peak on this profile. Although the lack of quantum entanglement limits the {\em size} of our database, our results show that entanglement is neither necessary for the algorithm itself, nor for its efficiency.Comment: 4 pages, 3 figures; minor revisions plus extra referenc

    Coherent Dual Comb Spectroscopy at High Signal to Noise

    Full text link
    Two frequency combs can be used to measure the full complex response of a sample in a configuration which can be alternatively viewed as the equivalent of a dispersive Fourier transform spectrometer, infrared time domain spectrometer, or a multiheterodyne laser spectrometer. This dual comb spectrometer retains the frequency accuracy and resolution inherent to the comb sources. We discuss, in detail, the specific design of our coherent dual-comb spectrometer and demonstrate the potential of this technique by measuring the first overtone vibration of hydrogen cyanide, centered at 194 THz (1545 nm). We measure the fully normalized, complex response of the gas over a 9 THz bandwidth at 220 MHz frequency resolution yielding 41,000 resolution elements. The average spectral signal-to-noise ratio (SNR) is 2,500 for both the fractional absorption and the phase, with a peak SNR of 4,000 corresponding to a fractional absorption sensitivity of 0.025% and phase sensitivity of 250 microradians. As the spectral coverage of combs expands, this dual-comb spectroscopy could provide high frequency accuracy and resolution measurements of a complex sample response across a range of spectral regions.Comment: 18 pages, 8 figures updated references, updated to match publication versio

    Prospects for precision measurements of atomic helium using direct frequency comb spectroscopy

    Full text link
    We analyze several possibilities for precisely measuring electronic transitions in atomic helium by the direct use of phase-stabilized femtosecond frequency combs. Because the comb is self-calibrating and can be shifted into the ultraviolet spectral region via harmonic generation, it offers the prospect of greatly improved accuracy for UV and far-UV transitions. To take advantage of this accuracy an ultracold helium sample is needed. For measurements of the triplet spectrum a magneto-optical trap (MOT) can be used to cool and trap metastable 2^3S state atoms. We analyze schemes for measuring the two-photon 23S43S2^3S \to 4^3S interval, and for resonant two-photon excitation to high Rydberg states, 23S33Pn3S,D2^3S \to 3^3P \to n^3S,D. We also analyze experiments on the singlet-state spectrum. To accomplish this we propose schemes for producing and trapping ultracold helium in the 1^1S or 2^1S state via intercombination transitions. A particularly intriguing scenario is the possibility of measuring the 11S21S1^1S \to 2^1S transition with extremely high accuracy by use of two-photon excitation in a magic wavelength trap that operates identically for both states. We predict a ``triple magic wavelength'' at 412 nm that could facilitate numerous experiments on trapped helium atoms, because here the polarizabilities of the 1^1S, 2^1S and 2^3S states are all similar, small, and positive.Comment: Shortened slightly and reformatted for Eur. Phys. J.
    corecore