519 research outputs found

    Time dependent transformations in deformation quantization

    Full text link
    We study the action of time dependent canonical and coordinate transformations in phase space quantum mechanics. We extend the covariant formulation of the theory by providing a formalism that is fully invariant under both standard and time dependent coordinate transformations. This result considerably enlarges the set of possible phase space representations of quantum mechanics and makes it possible to construct a causal representation for the distributional sector of Wigner quantum mechanics.Comment: 16 pages, to appear in the J. Math. Phy

    Generalized Weyl-Wigner map and Vey quantum mechanics

    Get PDF
    The Weyl-Wigner map yields the entire structure of Moyal quantum mechanics directly from the standard operator formulation. The covariant generalization of Moyal theory, also known as Vey quantum mechanics, was presented in the literature many years ago. However, a derivation of the formalism directly from standard operator quantum mechanics, clarifying the relation between the two formulations is still missing. In this paper we present a covariant generalization of the Weyl order prescription and of the Weyl-Wigner map and use them to derive Vey quantum mechanics directly from the standard operator formulation. The procedure displays some interesting features: it yields all the key ingredients and provides a more straightforward interpretation of the Vey theory including a direct implementation of unitary operator transformations as phase space coordinate transformations in the Vey idiom. These features are illustrated through a simple example.Comment: 15 pages, LaTe

    Quantification of GHB and GHB-GLUC in an 1,4-butanediol intoxication: a case report

    Get PDF
    Gamma-hydroxybutyric acid (GHB) is an endogenous compound with known action at the neural level. Its psychoactive effects led to an illicit use context including recreational purposes, muscle building effects in bodybuilders and drug-facilitated crimes, specifically in sexual assaults. Besides the misuse of the main compound, there are precursors like Gammabutyrolactone (GBL) and 1,4-butanediol (1,4-BD), usually non controlled substances, becoming a much easier way to obtain the target-compound. The authors present the first reported intoxication case in Portugal with 1,4-Butanediol, including the quantification of GHB and GHB-GLUC in serum, by GC-MS/MS TQD. A suspicious liquid and a serum sample were sent by an hospital ER and analysed by GC-MS-single quadrupole and GC-MS/MS TQD, respectively. A methodology including protein precipitation and GC-MS/MS TQD analysis was used to detect and quantify GHB and GHB-GLUC in serum. Toxicological analysis revealed the presence of 1,4-Butanediol in the liquid and GHB [171 mg/L] and GHB-GLUC [13,7 mg/L] in serum. The victim reverted the coma with no neurological sequelae. This was the first detected case, in Portugal, with 1,4-Butanediol, suggesting that it is important to be aware that consumers have different options to obtain illicit compounds, such as GHB. On the other hand, GHB-GLUC was identified and quantified for the first time in a real case, due to intoxication. This case highlights the importance of analysing all samples for active compounds, precursors and metabolites that can lead to the main intoxication origin.publishe

    Assessment of habitat suitability for common cockles in the Ria the Aveiro Lagoon under average and projected environmental conditions

    Get PDF
    The common cockle Cerastoderma edule is a widespread bivalve species inhabiting estuarine systems across the North East Atlantic, where it provides several ecosystem services, and represents a valuable fishery resource for local economies. However, anthropogenic pressure and more frequent extreme weather events threaten the resilience of the species. Spatially explicit information on species distribution is critical for the implementation of management and conservation practices. This study assessed the potential distribution of C. edule in the Ria de Aveiro by estimating the habitat suitability using an ensemble approach based on ecological niche modeling and recently developed hydrodynamic and water quality models to forecast both average and projected estuarine conditions. The models were developed for the summer of 2013 and spring of 2019 and potential range shifts in the species distribution were forecasted under projected environmental conditions: high and low estimates of freshwater discharge, a 2 °C increase in water temperature, and the combined effect of low freshwater discharge and increased water temperature. The results suggest that salinity, time of submersion, and current velocity play an important role in the distribution of cockles, and large areas were consistently classified with high habitat suitability. Increased freshwater discharge (both seasons) and low discharge coupled to increased temperature (spring) resulted in large decreases in suitable habitat. Conversely, low freshwater discharges and average (unchanged) temperatures increased the suitable habitat in the outermost regions of the Ria. The spatially explicit information provided contributes to a better understanding of the vulnerability of C. edule in the Ria de Aveiro to extreme weather events (e.g., droughts, river floods) and may support adaptive management strategies of the cockle fishery during these conditions. Moreover, this approach can be transferred to other estuarine ecosystems for which data describing the environmental conditions (e.g., derived from numerical models), and information about species presence are available (including data-poor species).publishe

    On the implementation of the gamma function for image correction on a endoscopic camera

    Get PDF
    This paper describes part of project that implemented the image processing of a CMOS sensor for endoscopic purposes. The sensor is a small sized device of 1x1mm2 and the image processing has been done inside a FPGA. This part of the work describes the implementation of the Gamma function with a balance between the resources needed and the accuracy. A linear piecewise solution was used that stores the values for 31 gamma functions with values ranging from 1 to 4 with 0.1 steps. The solution developed is 10 bit based, was coded in VHDL and is implemented in a Spartan 6 FPGA. The results show that it is an accurate solution that has a small footprint in terms of used resources.info:eu-repo/semantics/publishedVersio

    Full image-processing pipeline in field-programmable gate array for a small endoscopic camera

    Get PDF
    Endoscopy is an imaging procedure used for diagnosis as well as for some surgical purposes. The camera used for the endoscopy should be small and able to produce a good quality image or video, to reduce discomfort of the patients, and to increase the efficiency of the medical team. To achieve these fundamental goals, a small endoscopy camera with a footprint of 1 mm × 1 mm × 1.65 mm is used. Due to the physical prop erties of the sensors and human vision system limitations, different image-processing algorithms, such as noise reduction, demosaicking, and gamma correction, among others, are needed to faithfully reproduce the image or video. A full image-processing pipeline is implemented using a field-programmable gate array (FPGA) to accomplish a high frame rate of 60 fps with minimum processing delay. Along with this, a viewer has also been developed to display and control the image-processing pipeline. The control and data transfer are done by a USB 3.0 end point in the computer. The full developed system achieves real-time processing of the image and fits in a Xilinx Spartan-6LX150 FPGA.info:eu-repo/semantics/publishedVersio

    Modelo impresso em 3D usado num planeamento cirúrgico de um cão com radius curvus

    Get PDF
    An 8 month-old, 10 kg male Azawakh dog was presented due to worsening forelimb gait and exercise intolerance. The right forelimb presented gross angular limb deformity with carpal valgus and radial procurvatum. Surgical planning based on radiographs allowed calculation of the centers of rotation and angularity (CORAs). The computer tomography data were used to generate 3D reconstructions of the antebrachium to aid the detection of the orthopaedic problems. With proper imaging software, the nature of the deformity and its degree were quantified using a previously unreported method based on the CORAs as a 3D printed model of anatomical area of interest. This 3D printed model was used by the surgeon to simulate the surgery with all orthopaedic steps, which included a partial ulna osteotomy and a double cuneiform osteotomy of the radius performed at the level of CORAs and stabilized with bone plates and screws. After 7 weeks, radiographs revealed bone union. At 8 months after surgery the animal presented a complete recovery of the involved forelimb. CORAs method combined with computed tomography and 3D model was useful to plan and simulate surgical procedures, including the corrective surgery of forelimb deformities in a dog which improved the surgical efficiency comparatively to the conventional pre-operative study.Um cão com 8 meses de idade, 10kg de peso vivo, macho da raça Azawakh foi apresentado à clínica devido à intolerância ao exercício e agravamento da marcha do membro anterior. O membro anterior direito apresentou uma deformidade angular com valgus carpal e com um procarvatum radial. O planeamento cirúrgico inicialmente baseado em exames radiográficos possibilitou o cálculo dos centros de rotação e angulação articulares (CORAs). O exame de tomografia computadorizada foi utilizado juntamente com um software de imagiologia para obter o modelo 3D virtual da área anatómica de interesse que foi posteriormente impresso em 3D e que permitiu quantificar micrometricamente a deformação óssea presente. Este modelo 3D foi utilizado pelos cirurgiões para executar uma simulação cirúrgica completa que englobou todos os procedimentos cirúrgicos, que incluiu a realização de várias osteotomias e aplicação do material cirúrgico (placas e parafusos). Com base na simulação cirúrgica foi executada a cirurgia ao animal. Decorridas sete semanas, as radiografias demonstraram uma correta regeneração óssea. Oito meses após a cirurgia o animal apresentou uma recuperação completa. O método dos CORAs juntamente com a tomografia computadorizada e com a utilização do modelo 3D revelou-se útil no planeamento e na simulação dos vários procedimentos cirúrgicos, resultando numa melhoria significativa da eficiência cirúrgica
    corecore