10 research outputs found

    A 17-gene Assay to Predict Prostate Cancer Aggressiveness in the Context of Gleason Grade Heterogeneity, Tumor Multifocality, and Biopsy Undersampling

    Full text link
    avai lable at www.sciencedirect.com journal homepage: www.europeanurology.com Genomic Prostate Score Outcome measures and statistical analysis: The main outcome measures defining aggressive PCa were clinical recurrence, PCa death, and adverse pathology at prostatec-predictive of aggressClinical validation Clinical utility tomy. Cox proportional hazards regressionmodels were used to evaluate the association between gene expression and time to event end points. Results from the prostatectomy and biopsy studies were used to develop and lock a multigene-expression-based signature, called the Genomic Prostate Score (GPS); in the validation study, logistic regression was used to test the association between the GPS and pathologic stage and grade at prostatectomy. Decision-curve analysis and risk profileswere used together with clinical and pathologic characteristics to evaluate clinical utility. Results and limitations: Of the 732 candidate genes analyzed, 288 (39%) were found to predict clinical recurrence despite heterogeneity and multifocality, and 198 (27%) were ive disease after adjustment for prostate-specific antigen, GleasonArticle inf

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data
    corecore