8 research outputs found

    A Prognostic Framework for Wheel Treads Integrating Parameter Correlation and Multiple Uncertainties

    No full text
    As crucial rotary components of high-speed trains, wheel treads in realistic operation environment usually suffer severe cyclic shocks, which damage the health status and ultimately cause safety risks. Timely and precise health prognosis based on vibration signals is an effective technology to mitigate such risks. In this work, a new parameter-related Wiener process model is proposed to capture multiple uncertainties existed in on-site prognosis of wheel treads. The proposed model establishes a quantitative relationship between degradation rate and variations, and integrates uncertainties via heterogeneity analysis of both criterions. A maximum-likelihood-based method is presented to initialize the unknown model parameters, followed by a recursive update algorithm with fully utilization of historical lifetime information. An investigation of real-world wheel tread signals demonstrates the superiority of the proposed model in accuracy improvement

    CMISG1701: a multicenter prospective randomized phase III clinical trial comparing neoadjuvant chemoradiotherapy to neoadjuvant chemotherapy followed by minimally invasive esophagectomy in patients with locally advanced resectable esophageal squamous cell carcinoma (cT3-4aN0-1M0) (NCT03001596)

    No full text
    Abstract Background Neoadjuvant chemoradiation is not recommended as an approach for treatment of esophageal squamous cell carcinoma due to its significant postoperative mortality. However, it is assumed the combination of neoadjuvant chemoradiation with minimally invasive esophagectomy (MIE) may reduce postoperative mortality, which can revive preoperative chemoradiation. No randomized controlled studies comparing neoadjuvant chemoradiation plus MIE with neoadjuvant chemotherapy plus MIE have been performed so far. The present trial is initiated to obtain valid information whether neoadjuvant chemoradiation plus MIE yields better survival without worse postoperative morbidity and mortality in the treatment of locally advanced resectable esophageal squamous cell carcinoma(cT3-4aN0-1M0). Methods/design CMISG1701 is a multicenter, prospective, randomized, phase III clinical trial, investigating the safety and efficacy of neoadjuvant chemoradiation plus MIE compared with neoadjuvant chemotherapy plus MIE. Patients with locally advanced resectable esophageal squamous cell carcinoma (cT3-4aN0-1M0) are eligible for the study. A total of 264 patients are randomly assigned to neoadjuvant chemoradiation (arm A) or neoadjuvant chemotherapy (arm B) with a 1:1 allocation ratio. The primary outcome is overall survival assessed with a minimum follow-up of 36 months. Secondary outcomes are progression-free survival, recurrence-free survival, postoperative pathologic stage, treatment-related complications, postoperative mortality as well as quality of life. Discussion The objective of this trial is to identify the superior protocol with regard to patient survival, treatment morbidity/mortality and quality of life between neoadjuvant chemoradiation plus MIE and neoadjuvant chemotherapy plus MIE. Trial registration NCT03001596 (December 17, 2016)

    The Society for Translational Medicine: Clinical practice guidelines for the postoperative management of chest tube for patients undergoing lobectomy

    No full text
    The Society for Translational Medicine and The Chinese Society for Thoracic and Cardiovascular Surgery conducted a systematic review of the literature in an attempt to improve our understanding in the postoperative management of chest tubes of patients undergoing pulmonary lobectomy. Recommendations were produced and classified based on an internationally accepted GRADE system. The following recommendations were extracted in the present review: (I) chest tubes can be removed safely with daily pleural fluid of up to 450 mL (non-chylous and non-sanguinous), which may reduce chest tube duration and hospital length of stay (2B); (II) in rare instances, e.g., persistent abundant fluid production, the use of PrRP/B< 0.5 when evaluating fluid output to determine chest tube removal might be beneficial (2B); (III) it is recommended that one chest tube is adequate following pulmonary lobectomy, except for hemorrhage and space problems (2A); (IV) chest tube clearance by milking and stripping is not recommended after lung resection (2B); (V) chest tube suction is not necessary for patients undergoing lobectomy after first postoperative day (2A); (VI) regulated chest tube suction [-11 (-1.08 kPa) to -20 (1.96 kPa) cmH2O depending upon the type of lobectomy] is not superior to regulated seal [-2 (0.196 kPa) cmH2O] when electronic drainage systems are used after lobectomy by thoracotomy (2B); (VII) chest tube removal recommended at the end of expiration and may be slightly superior to removal at the end of inspiration (2A); (VIII) electronic drainage systems are recommended in the management of chest tube in patients undergoing lobectomy (2B)
    corecore