155 research outputs found

    INTERACTION BETWEEN ARGON AND DOPANTS IN SPUTTERED a-Si : H

    No full text
    The concentrations of As, B, H, Ar and Si in sputtered a-Si : H are measured by helium Rutherford backscattering and nuclear reactions analysis. Excess or deficit of hydrogen and argon by comparison with intrinsic a-Si : H are found in presence of dopants at high deposition rate. This is related to the plasma deposition method and would suggest micro grain structure in the deposited layer

    Optical properties of hydrogenated amorphous silicon

    Get PDF
    A detailed study of the optical properties of sputtered hydrogenated amorphous silicon films with varying hydrogen concentration is presented here. The energy dependence of the absorption coefficient is looked into, in detail, from a point of view of understanding the well known Tauc rule and the alternate relations being proposed in recent years. Spectroscopic and band‐structural models like Wemple-Didomenico and Penn are then utilized to analyze the optical parameters near the band‐gap region of the wavelength spectra. Extensive comparisons of our results are made with those of sputtered a‐Si:H films of other workers, glow discharge prepared a‐Si:H, chemically vapor deposited and evaporated a‐Si, and also crystalline silicon. The similarities in the variation of the optical properties of a‐Si:H with increasing hydrogen concentration (or decreasing measurement temperature) to that of crystalline silicon with decreasing measurement temperature lead us to interesting conclusions. Thus, it seems that decreasing disorder (topological or thermal) in a‐Si:H is equivalent to decreasing thermal disorder in c‐Si, at least as far as the disorder‐optical property relationships are concerned

    Macrorheology of cystic fibrosis, chronic obstructive pulmonary disease & normal sputum

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Prior microrheologic assessments of selected, microlitre plugs of cystic fibrosis (CF) sputum suggest no intrinsic rheologic abnormality. However, such analyses may not be representative of CF sputum as a whole. We therefore reassessed this question using whole sputum macrorheology. Additionally, we wished to further explore the relationships between sputum rheology, inflammation and infection.</p> <p>Methods</p> <p>Dynamic oscillatory macrorheometry was performed on whole expectorated sputum from stable adults with CF (n = 18) and COPD (n = 12) and induced sputum from normal controls (n = 7). Concomitant sputum inflammatory mediator levels were measured in CF and COPD samples. Sputum collected from CF subjects (n = 6) at commencement and completion of intravenous antibiotic therapy for an infective exacerbation was also assessed.</p> <p>Results</p> <p>CF sputum neutrophil elastase activity (NE) was significantly related to degree of sputum purulence (p = 0.049) and correlated significantly with measures of sputum viscoelasticity (r = 0.696, p = 0.008 for storage modulus G' at 9 Hz). There were significant differences in viscoelasticity between subject groups when samples were compared irrespective of appearance/degree of sputum purulence. However, the macrorheology of mucoid CF sputum did not differ from normal sputum (eg median (range) G' at 9 Hz 2.25 (0.79, 3.26) vs 2.04 (1.4,4.6) Pa, p = 1). In contrast, mucoid COPD samples demonstrated significantly greater viscoelasticity (G' at 9 Hz 4.5 (2.4, 23) Pa) than sputum from both CF (p = 0.048) & normal subjects (p = 0.009). Antibiotic therapy during exacerbations was associated with significant reductions in CF sputum viscoelasticity, with mean (SD) G' at 9 Hz decreasing from 28.5 (11.5) Pa at commencement to 6.4 (4.6) Pa on day 7 (p = 0.01).</p> <p>Conclusion</p> <p>The macrorheologic properties of whole, mucoid CF sputum are not different from normal, confirming the results of prior microrheologic studies. Instead, CF sputum viscoelasticity is related to secondary infection, decreases with intravenous antibiotic therapy and correlates with inflammation. In contrast, COPD sputum demonstrates inherently greater viscoelasticity, providing a novel target for potential therapeutic interventions.</p

    The CF-CIRC study: a French collaborative study to assess the accuracy of Cystic Fibrosis diagnosis in neonatal screening

    Get PDF
    BACKGROUND: Cystic fibrosis (CF) is caused by mutations in the gene encoding for the CF transmembrane conductance regulator (CFTR) protein, which acts as a chloride channel after activation by cyclic AMP (cAMP). Newborn screening programs for CF usually consist of an immunoreactive trypsinogen (IRT) assay, followed when IRT is elevated by testing for a panel of CF-causing mutations. Some children, however, may have persistent hypertrypsinogenemia, only one or no identified CFTR gene mutation, and sweat chloride concentrations close to normal values. In vivo demonstration of abnormal CFTR protein function would be an important diagnostic aid in this situation. Measurements of transepithelial nasal potential differences (NPD) in adults accurately characterize CFTR-related ion transport. The aim of the present study is to establish reference values for NPD measurements for healthy children and those with CF aged 3 months to 3 years, the age range of most difficult-to-diagnose patients with suspected CF. The ultimate goal of our study is to validate NPD testing as a diagnostic tool for children with borderline results in neonatal screening. METHODS/DESIGN: We adapted the standard NPD protocol for young children, designed a special catheter for them, used a slower perfusion rate, and shortened the protocol to include only measurement of basal PD, transepithelial sodium (Na(+)) transport in response to the Na(+ )channel inhibitor amiloride, and CFTR-mediated chloride (Cl(-)) secretion in response to isoproterenol, a ÎČ-agonist in a Cl(- )free solution. The study will include 20 children with CF and 20 healthy control children. CF children will be included only if they carry 2 CF-causing mutations in the CFTR gene or have sweat chloride concentrations > 60 mEq/L or both. The healthy children will be recruited among the siblings of the CF patients, after verification that they do not carry the familial mutation. DISCUSSION: A preliminary study of 3 adult control subjects and 4 children older than 12 years with CF verified that the new protocol was well tolerated and produced NPD measurements that did not differ significantly from those obtained with the standard protocol. This preliminary study will provide a basis for interpreting NPD measurements in patients with suspected CF after neonatal screening. Earlier definitive diagnosis should alleviate parental distress and allow earlier therapeutic intervention and genetic counseling

    Performance of irradiated CVD diamond micro-strip sensors

    Get PDF
    CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a ÎČ\beta-source and the performance before and after intense (>1015/cm2>10^{15}/{\rm cm^2}) proton- and pion-irradiations. We find that low dose irradiations increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiations with protons (2.2×1015 p/cm22.2\times 10^{15}~p/{\rm cm^2}) lowers the signal-to-noise ratio slightly. Intense irradiation with pions (2.9×1015 π/cm22.9\times 10^{15}~\pi/{\rm cm^2}) lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations

    Development of CVD diamond radiation detectors

    Get PDF
    Diamond is a nearly ideal material for detecting ionizing radiation. Its outstanding radiation hardness, fast charge collection and low leakage current allow a diamond detector to be used in high ra diation, high temperature and in aggressive chemical media. We have constructed charged particle detectors using high quality CVD diamond. Characterization of the diamond samples and various detect ors are presented in terms of collection distance, d=ÎŒEτd=\mu E \tau, the average distance electron-hole pairs move apart under the influence of an electric field, where ÎŒ\mu is the sum of carrier mo bilities, EE is the applied electric field, and τ\tau is the mobility weighted carrier lifetime. Over the last two years the collection distance increased from ∌\sim 75 ÎŒ\mum to over 200 ÎŒ\mu m. With this high quality CVD diamond a series of micro-strip and pixel particle detectors have been constructed. These devices were tested to determine their position resolution and signal to n oise performance. Diamond detectors were exposed to large fluences of pions, protons and neutrons to establish their radiation hardness properties. The results of these tests and their correlati on with the characterization studies are presented
    • 

    corecore