4,816 research outputs found
Rare occult macular dystrophy with a pathogenic variant in the RP1L1 gene in a patient of Swiss descent
Purpose: We report a first case of bilateral occult macular dystrophy (OMD) with a c.133C>T (p.Arg45Trp) pathogenic variant in the retinitis pigmentosa 1-like 1 (RP1L1) gene in a patient of Caucasian Swiss decent. Observations: A 34-year-old man presented with decreased visual acuity known since childhood. Fundus examination of both eyes revealed no pathology other than mildly increased granularity of the foveal retinal pigment epithelium. The full-field electroretinogram (ffERG) presented with normal findings while the multifocal electroretinogram (mfERG) showed severely reduced amplitudes of the foveal response. Optical coherence tomography (OCT) showed foveal outer retinal atrophy. Fundus autofluorescence (FAF) imaging demonstrated near-normal findings with minimal mottling at the posterior pole. The genetic analysis revealed a heterozygous pathogenic variant (c.133C>T, p.Arg45Trp) in the RP1L1 gene. Conclusion and importance: Our present case suggests that OMD shows a wide range of clinical presentations with a variety of ophthalmological findings, age of disease onset, visual acuity, and genetic diversity
Electrochemical and optical study of the confined aqueous layer adsorbed on gold electrodes cycled in phosphate and dodecylsulphate solutions
The properties of the confined aqueous layer potentiodynamically formed on polycrystalline gold in aqueous phosphate and sodium dodecylsulphate solutions were studied using voltammetry, ellipsometry, and contact angle measurements. The nature of the incipient oxide layer was analyzed as a function of the cycling time in the double layer-oxide monolayer potential region. The replacement of the electrolyte by hexane allows the increase of the optical signal. Different potential cycling conditions change the homogeneity of the confined aqueous incipient oxide layer leading to different structural characteristics.Instituto de Investigaciones Fisicoquímicas Teóricas y AplicadasFacultad de Ciencias Exacta
IgD Multiple Myeloma Paraproteinemia as a Cause of Myositis
A 48-years old man was diagnosed an IgD-k multiple myeloma (MM) at age 38 years for which he successfully underwent chemotherapy and bone marrow transplant. He then developed a graft-versus-host disease (GVHD) whose manifestations included, three years later, a polymyositis, diagnosed at muscle biopsy and successfully treated with steroids. Few months after polymyositis remission, myeloma relapsed and the patient was treated with thalidomide for six years with good remission. Soon after thalidomide suspension, MM relapsed again and the patient came to our observation for a new onset of neuromuscular symptoms. He underwent both muscle and peripheral nerve biopsy to discriminate between myositis (paraproteinemia versus GVHD), amyloidosis, and thalidomide toxicity. The first muscle biopsy showed an inflammatory pattern with necrotic fibres, macrophagical invasion (CD68 positive), rare interstitial cellular infiltrates (CD8 positive and CD4 negative), widespread anti-HLA positivity and negative antiMAC. The second muscle biopsy showed the same inflammatory pattern plus an involvement of blood vessels. Direct immunofluorescence for IgD showed diffuse positivity along the sarcolemmal in both muscle biopsies. Sural nerve biopsy demonstrated both demyelinating and axonal aspects with no inflammatory infiltrates, but positivity for HLA and MAC. Congo Red was negative in both skeletal muscle and peripheral nerve
Lightweight Model for Session-Based Recommender Systems with Seasonality Information in the Fashion Domain
This paper presents the solution designed by the team "Boston Team Party"for the ACM RecSys Challenge 2022. The competition was organized by Dressipi and was framed under the session-based fashion recommendations domain. Particularly, the task was to predict the purchased item at the end of each anonymous session. Our proposed two-stage solution is effective, lightweight, and scalable. First, it leverages the expertise of several strong recommendation models to produce a pool of candidate items. Then, a Gradient-Boosting Decision Tree model aggregates these candidates alongside several hand-crafted features to produce the final ranking. Our model achieved a score of 0.18800 in the public leaderboard. To aid in the reproducibility of our findings, we open-source our materials
Electrochemical and optical study of the confined aqueous layer adsorbed on gold electrodes cycled in phosphate and dodecylsulphate solutions
The properties of the confined aqueous layer potentiodynamically formed on polycrystalline gold in aqueous phosphate and sodium dodecylsulphate solutions were studied using voltammetry, ellipsometry, and contact angle measurements. The nature of the incipient oxide layer was analyzed as a function of the cycling time in the double layer-oxide monolayer potential region. The replacement of the electrolyte by hexane allows the increase of the optical signal. Different potential cycling conditions change the homogeneity of the confined aqueous incipient oxide layer leading to different structural characteristics.Instituto de Investigaciones Fisicoquímicas Teóricas y AplicadasFacultad de Ciencias Exacta
Implantable hearing devices in clinical practice. Systematic review and consensus statements
Objective. Implantable hearing devices represent a modern and innovative solution for hearing restoration. Over the years, these high-tech devices have increasingly evolved but their use in clinical practice is not universally agreed in the scientific literature. Congresses, meetings, conferences, and consensus statements to achieve international agreement have been made. This work follows this line and aims to answer unsolved questions regarding examinations, selection criteria and surgery for implantable hearing devices. Materials and methods. A Consensus Working Group was established by the Italian Society of Otorhinolaryngology. A method group performed a systematic review for each single question to identify the current best evidence on the topic and to guide a multidisciplinary panel in developing the statements. Results. Twenty-nine consensus statements were approved by the Italian Society of Otorhinolaryngology. These were associated with 4 key area subtopics regarding pre -operative tests, otological, audiological and surgical indications. Conclusions. This consensus can be considered a further step forward to establish realistic guidelines on the debated topic of implantable hearing devices
Large scale characterization and calibration strategy of a SiPM-based camera for gamma-ray astronomy
The SST-1M is a 4-m diameter mirror Davies-Cotton gamma-ray telescope. It has
been designed to cover the energy range above 500 GeV and to be part of an
array of telescopes separated by 150-200 m. Its innovative camera is featuring
large area hexagonal silicon photo-multipliers as photon detectors and a fully
digital trigger and readout system. Here, the strategy and the methods for its
calibration are presented, together with the obtained results. In particular,
the off and on-site calibration strategies are demonstrated on the first camera
prototype. The performances of the camera in terms of charge and time
resolution are described
Evidence for the existence of powder sub-populations in micronized materials : Aerodynamic size-fractions of aerosolized powders possess distinct physicochemical properties
This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.Purpose: To investigate the agglomeration behaviour of the fine ( 12.8 µm) particle fractions of salmeterol xinafoate (SX) and fluticasone propionate (FP) by isolating aerodynamic size fractions and characterising their physicochemical and re-dispersal properties. Methods: Aerodynamic fractionation was conducted using the Next Generation Impactor (NGI). Re-crystallized control particles, unfractionated and fractionated materials were characterized for particle size, morphology, crystallinity and surface energy. Re-dispersal of the particles was assessed using dry dispersion laser diffraction and NGI analysis. Results: Aerosolized SX and FP particles deposited in the NGI as agglomerates of consistent particle/agglomerate morphology. SX particles depositing on Stages 3 and 5 had higher total surface energy than unfractionated SX, with Stage 5 particles showing the greatest surface energy heterogeneity. FP fractions had comparable surface energy distributions and bulk crystallinity but differences in surface chemistry. SX fractions demonstrated higher bulk disorder than unfractionated and re-crystallized particles. Upon aerosolization, the fractions differed in their intrinsic emission and dispersion into a fine particle fraction (< 5.0 µm). Conclusions: Micronized powders consisted of sub-populations of particles displaying distinct physicochemical and powder dispersal properties compared to the unfractionated bulk material. This may have implications for the efficiency of inhaled drug deliveryPeer reviewe
Reproducibility of postural control measurement during unstable sitting in low back pain patients
<p>Abstract</p> <p>Background</p> <p>Postural control tests like standing and sitting stabilometry are widely used to evaluate neuromuscular control related to trunk balance in low back pain patients. Chronic low back pain patients have lesser postural control compared to healthy subjects. Few studies have assessed the reproducibility of the centre of pressure deviations and to our knowledge no studies have investigated the reproducibility of three-dimensional kinematics of postural control tests in a low back pain population. Therefore the aim of this study was to assess the test-retest reproducibility of a seated postural control test in low back pain patients.</p> <p>Methods</p> <p>Postural control in low back pain patients was registered by a three dimensional motion analysis system combined with a force plate. Sixteen chronic low back pain patients having complaints for at least six months, were included based on specific clinical criteria. Every subject performed 4 postural control tests. Every test was repeated 4 times and lasted 40 seconds. The force plate registered the deviations of the centre of pressure. A Vicon-612-datastation, equipped with 7 infra-red M1 camera's, was used to track 13 markers attached to the torso and pelvis in order to estimate their angular displacement in the 3 cardinal planes.</p> <p>Results</p> <p>All Intraclass Correlation Coefficients (ICC) calculated for the force plate variables did not exceed 0.73 (ranging between 0.11 and 0.73). As for the torso, ICC's of the mean flexion-extension and rotation angles ranged from 0.65 to 0.93 and of the mean lateral flexion angle from 0.50 to 0.67. For the pelvis the ICC of the mean flexion-extension angle varied between 0.66 and 0.83, the mean lateral flexion angle between 0.16 and 0.81 and the mean rotation angle between 0.40 and 0.62.</p> <p>Consecutive data suggest that the low test-retest reproducibility is probably due to a learning effect.</p> <p>Conclusion</p> <p>The test-retest reproducibility of these postural control tests in an unstable sitting position can globally be considered as rather moderate. In order to improve the test-retest reproducibility, a learning period may be advisable at the beginning of the test.</p
A Multicenter Clinical Evaluation of Data Logging in Cochlear Implant Recipients Using Automated Scene Classification Technologies
Currently, there are no studies assessing everyday use of cochlear implant (CI) processors by recipients by means of objective tools. The Nucleus 6 sound processor features a data logging system capable of real-time recording of CI use in different acoustic environments and under various categories of loudness levels. In this study, we report data logged for the different scenes and different loudness levels of 1,366 CI patients, as recorded by SCAN. Monitoring device use in cochlear implant recipients of all ages provides important information about the listening conditions encountered in recipients' daily lives that may support counseling and assist in the further management of their device settings. The findings for this large cohort of active CI users confirm differences between age groups concerning device use and exposure to various noise environments, especially between the youngest and oldest age groups, while similar levels of loudness were observed
- …