92 research outputs found

    Quality factor and finesse optimization in buried InGaAsP/InP ring resonators

    Get PDF
    Quality factor and finesse of buried In1-xGaxAsyP1-y / InP ring resonators have been optimized in this paper by a very general modelling technique. Limiting effect of propagation loss within the ring has been investigated using a three-dimensional (3D) highly accurate complex mode solver based on mode matching method to analyze bending loss dependence on ring radius and wavelength. Coupling between straight input/output (I/O) bus waveguides and ring resonator has been studied by 3D Beam Propagation Method (BPM), deriving coupling loss and coupling coefficient for a large range of ring radius and bus waveguides-ring distance values (for both polarizations). Ring resonator has been modelled by the transfer-matrix approach, while finesse and quality factor dependence on radius has been estimated for two resonator architectures (including one or two I/O bus waveguides) and for quasi-TE and quasi-TM modes. Guiding structure has been optimized to enhance resonator performance. The modelling approach has been validated by comparing results obtained by our algorithm with experimental data reported in literature. Influence of rejection (at resonance wavelength) at through port on quality factor and finesse has been widely discussed. A quality factor larger than 8 x 105 has been predicted for the ring resonator employing only one I/O bus waveguide and having a radius of 400 μm. This resonator exhibits a rejection of -8 dB at through port

    Ultra-high Q/V hybrid cavity for strong light-matter interaction

    Get PDF
    The ability to confine light at the nanoscale continues to excite the research community, with the ratio between quality factor Q and volume V, i.e., the Q/V ratio, being the key figure of merit. In order to achieve strong light-matter interaction, however, it is important to confine a lot of energy in the resonant cavity mode. Here, we demonstrate a novel cavity design that combines a photonic crystal nanobeam cavity with a plasmonic bowtie antenna. The nanobeam cavity is optimised for a good match with the antenna and provides a Q of 1700 and a transmission of 90%. Combined with the bowtie, the hybrid photonic-plasmonic cavity achieves a Q of 800 and a transmission of 20%, both of which remarkable achievements for a hybrid cavity. The ultra-high Q/V of the hybrid cavity is of order of 106 (λ/n)−3, which is comparable to the state-of-the-art of photonic resonant cavities. Based on the high Q/V and the high transmission, we demonstrate the strong efficiency of the hybrid cavity as a nanotweezer for optical trapping. We show that a stable trapping condition can be achieved for a single 200 nm Au bead for a duration of several minutes (ttrap > 5 min) and with very low optical power (Pin = 190 μW)

    Cranio-Mandibular Disorders after Whiplash Injury: A Mono-Institutional Clinical Study on 31 Patients

    Get PDF
    Background: Whiplash is a consequence of traumatic injuries, mostly related to road accidents, with variable clinical manifestations, also known as Whiplash Associated Disorders, such as neck, head and temporo-cranio-mandibular pain. Methods: The current study aims to evaluate the onset and evolution of temporomandibular joint pain in people with whiplash in a study group treated with the use of Zimmer Collars (adjustable rigid cervical collars for neck immobilization), as compared to a control group. This prospective study included 31 patients followed by the Dental Prosthesis Department of the University of Bari “Aldo Moro”: 20 patients with whiplash (age range: 20–39 years) treated with Zimmer collars and 11 patients with whiplash (age range: 20–33 years) who were not. Immediately after the whiplash occurred, a visual analogue scale (VAS) was used to describe the intensity of pain and to complete the chart of the European Academy of Craniomandibular Disorders. Five out of twenty patients, already treated with a Zimmer collar, wore an occlusal splint as well because of persistent pain reported at the 28-day and 60-day follow-up and were supported by pharmacological therapy with analgesics (paracetamol) and muscle relaxants (thiocolchicoside). Results: During the last follow-up (at six months), three out of five patients displayed a residual VAS score of 3, 4, and 5, respectively, while the remaining two displayed a VAS of 0. In the control group, four out of eleven patients needed to wear an occlusal splint but without muscle relaxants and analgesics pharmacological therapy; these four corresponded to the patients showing a residual painful symptomatology, with VAS reaching value of 2, and also were the oldest patients of the group. Data regarding VAS values and Zimmer collar use, both at the first visit and six months later, were statistically analyzed. Conclusion: Our prospective study highlights how whiplash-associated acute disorders are often self-limiting over a period of few months, thus reducing the possibility of symptom chronicity; the latter seems to be strictly related to lesion severity, pre-existence of a craniomandibular dysfunction and patient age, but appears to be independent from Zimmer collar use, as statistically confirmed

    Recent advances in miniaturized optical gyroscopes

    Get PDF
    Low-cost chip-scale optoelectronic gyroscopes having a resolution ≤ 10 °/h and a good reliability also in harsh environments could have a strong impact on the medium/high performance gyro market, which is currently dominated by well-established bulk optical angular velocity sensors. The R&D activity aiming at the demonstration of those miniaturized sensors is crucial for aerospace/defense industry, and thus it is attracting an increasing research effort and notably funds.  In this paper the recent technological advances on the compact optoelectronic gyroscopes with low weight and high energy saving are reviewed. Attention is paid to both the so-called gyroscope-on-a-chip, which is a novel sensor, at the infantile stage, whose optical components are monolithically integrated on a single indium phosphide chip, and to a new ultra-high Q ring resonator for gyro applications with a configuration including a 1D photonic crystal in the resonant path. The emerging field of the gyros based on passive ring cavities, which have already shown performance comparable with that of optical fiber gyros, is also discussed

    Primary diffuse large B-cell lymphoma of the breast: prognostic factors and outcomes of a study by the International Extranodal Lymphoma Study Group

    Get PDF
    Background: Primary diffuse large B-cell lymphoma (DLBCL) of breast is rare. We aimed to define clinical features, prognostic factors, patterns of failure, and treatment outcomes. Patients and methods: A retrospective international study of 204 eligible patients presenting to the International Extranodal Lymphoma Study Group-affiliated institutions from 1980 to 2003. Results: Median age was 64 years, with 95% of patients presenting with unilateral disease. Median overall survival (OS) was 8.0 years, and median progression-free survival 5.5 years. In multifactor analysis, favourable International Prognostic Index score, anthracycline-containing chemotherapy, and radiotherapy (RT) were significantly associated with longer OS (each P ≤ 0.03). There was no benefit from mastectomy, as opposed to biopsy or lumpectomy only. At a median follow-up time of 5.5 years, 37% of patients had progressed—16% in the same or contralateral breast, 5% in the central nervous system, and 14% in other extranodal sites. Conclusions: The combination of limited surgery, anthracycline-containing chemotherapy, and involved-field RT produced the best outcome in the pre-rituximab era. A prospective trial on the basis of these results should be pursued to confirm these observations and to determine whether the impact of rituximab on the patterns of relapse and outcome parallels that of DLBCL presenting at other site
    corecore