13 research outputs found

    A new MRI rating scale for progressive supranuclear palsy and multiple system atrophy: validity and reliability

    Get PDF
    AIM To evaluate a standardised MRI acquisition protocol and a new image rating scale for disease severity in patients with progressive supranuclear palsy (PSP) and multiple systems atrophy (MSA) in a large multicentre study. METHODS The MRI protocol consisted of two-dimensional sagittal and axial T1, axial PD, and axial and coronal T2 weighted acquisitions. The 32 item ordinal scale evaluated abnormalities within the basal ganglia and posterior fossa, blind to diagnosis. Among 760 patients in the study population (PSP = 362, MSA = 398), 627 had per protocol images (PSP = 297, MSA = 330). Intra-rater (n = 60) and inter-rater (n = 555) reliability were assessed through Cohen's statistic, and scale structure through principal component analysis (PCA) (n = 441). Internal consistency and reliability were checked. Discriminant and predictive validity of extracted factors and total scores were tested for disease severity as per clinical diagnosis. RESULTS Intra-rater and inter-rater reliability were acceptable for 25 (78%) of the items scored (≥ 0.41). PCA revealed four meaningful clusters of covarying parameters (factor (F) F1: brainstem and cerebellum; F2: midbrain; F3: putamen; F4: other basal ganglia) with good to excellent internal consistency (Cronbach α 0.75-0.93) and moderate to excellent reliability (intraclass coefficient: F1: 0.92; F2: 0.79; F3: 0.71; F4: 0.49). The total score significantly discriminated for disease severity or diagnosis; factorial scores differentially discriminated for disease severity according to diagnosis (PSP: F1-F2; MSA: F2-F3). The total score was significantly related to survival in PSP (p<0.0007) or MSA (p<0.0005), indicating good predictive validity. CONCLUSIONS The scale is suitable for use in the context of multicentre studies and can reliably and consistently measure MRI abnormalities in PSP and MSA. Clinical Trial Registration Number The study protocol was filed in the open clinical trial registry (http://www.clinicaltrials.gov) with ID No NCT00211224

    Radiotherapy for Prostate Cancer: is it ‘what you do’ or ‘the way that you do it’? A UK Perspective on Technique and Quality Assurance

    Full text link

    Cutting Edge:Retrobulbar inflammation, adipogenesis, and acute orbital congestion in a preclinical female mouse model of Graves' orbitopathy induced by thyrotropin receptor plasmid-in vivo electroporation

    No full text
    Graves' orbitopathy (GO) is a complication in Graves' disease (GD) but mechanistic insights into pathogenesis remain unresolved, hampered by lack of animal model. The TSH receptor (TSHR) and perhaps IGF-1 receptor (IGF-1R) are considered relevant antigens. We show that genetic immunization of human TSHR (hTSHR) A-subunit plasmid leads to extensive remodeling of orbital tissue, recapitulating GO. Female BALB/c mice immunized with hTSHR A-subunit or control plasmids by in vivo muscle electroporation were evaluated for orbital remodeling by histopathology and magnetic resonance imaging (MRI). Antibodies to TSHR and IGF-1R were present in animals challenged with hTSHR A-subunit plasmid, with predominantly TSH blocking antibodies and were profoundly hypothyroid. Orbital pathology was characterized by interstitial inflammation of extraocular muscles with CD3+ T cells, F4/80+ macrophages, and mast cells, accompanied by glycosaminoglycan deposition with resultant separation of individual muscle fibers. Some animals showed heterogeneity in orbital pathology with 1) large infiltrate surrounding the optic nerve or 2) extensive adipogenesis with expansion of retrobulbar adipose tissue. A striking finding that underpins the new model were the in vivo MRI scans of mouse orbital region that provided clear and quantifiable evidence of orbital muscle hypertrophy with protrusion (proptosis) of the eye. Additionally, eyelid manifestations of chemosis, including dilated and congested orbital blood vessels, were visually apparent. Immunization with control plasmids failed to show any orbital pathology. Overall, these findings support TSHR as the pathogenic antigen in GO. Development of a new preclinical model will facilitate molecular investigations on GO and evaluation of new therapeutic interventions.</jats:p

    Modeling positioning uncertainties of prostate cancer external beam radiation therapy using pre-treatment data

    No full text
    PURPOSE: To investigate the influence of treatment plan data and image guidance (IG) on positioning uncertainty during prostate cancer (PCa) radiotherapy (RT). METHODS: Body mass index (BMI), planning target volume (PTV), bladder volume (BV), and rectal cross section area (RCS) were collected for 267 consecutive PCa patients undergoing daily IGRT. Radiographic isocenter corrections to intra-prostatic fiducials for 12,490 treatment fractions were used to derive random (RE) and systematic (SE) inter-fraction uncertainties for the cardinal axes. These data were used to simulate RE and SE for weekly IG and Action Level (AL)-IG treatment protocols. RESULTS: SE and RE were 2–5 and 3–4 mm in the cardinal axes, respectively, during simulation of no IG. Without IG, positive correlations (p < 0.01) were noted for (1) anterior-posterior RE vs. RCS and BV and (2) cranio-caudal RE vs. RCS, BV and BMI. The RE increase was 3 mm for the highest quartile of RCS, BV and BMI. Daily IGRT eliminated this relationship. 3D IG corrections of 1 cm or more occured in 27% of treatment fractions and in 97% of patients. CONCLUSION: PCa patients with elevated pre-treatment BV, RCS and BMI have increased inter-fractionation positioning uncertainty and appear the primary candidates for daily IGRT

    Image-guided radiotherapy reduces the risk of under-dosing high-risk prostate cancer extra-capsular disease and improves biochemical control

    No full text
    Abstract Background To determine if reduced dose delivery uncertainty is associated with daily image-guidance (IG) and Prostate Specific Antigen Relapse Free Survival (PRFS) in intensity-modulated radiotherapy (IMRT) of high-risk prostate cancer (PCa). Methods Planning data for consecutive PCa patients treated with IMRT (n = 67) and IG-IMRT (n = 35) was retrieved. Using computer simulations of setup errors, we estimated the patient-specific uncertainty in accumulated treatment dose distributions for the prostate and for posterolateral aspects of the gland that are at highest risk for extra-capsular disease. Multivariate Cox regression for PRFS considering Gleason score, T-stage, pre-treatment PSA, number of elevated clinical risk factors (T2c+, GS7+ and PSA10+), nomogram-predicted risk of extra-capsular disease (ECD), and dose metrics was performed. Results For IMRT vs. IG-IMRT, plan dosimetry values were similar, but simulations revealed uncertainty in delivered dose external to the prostate was significantly different, due to positioning uncertainties. A patient-specific interaction term of the risk of ECD and risk of low dose to the ECD (p = 0.005), and the number of elevated clinical risk factors (p = 0.008), correlate with reduced PRFS. Conclusions Improvements in PSA outcomes for high-risk PCa using IG-IMRT vs. IMRT without IG may be due to improved dosimetry for ECD

    Additional file 1: of Image-guided radiotherapy reduces the risk of under-dosing high-risk prostate cancer extra-capsular disease and improves biochemical control

    No full text
    Table S1. The patient characteristics, for patients experiencing PSA relapse and control, respectively. Table S2. UNIVARIATE COX MODELS FOR THE CANDIDATE ECE DESCRIPTOR. The selected candidate with the strongest association with PSA relapse is marked (*). Table S3. Univariate and Multivariate Cox model analysis data predicting for PRFS for Non-IGRT patients ONLY. The multivariate model improved by the inclusion of the ECD descriptor (p=0.036). (ZIP 487 kb
    corecore