239 research outputs found

    L'institut des forêts et des pâturages de Karad

    Get PDF

    Condom-use Skills Checklist: A Proxy for Assessing Condom-use Knowledge and Skills When Direct Observation Is Not Possible

    Get PDF
    Because of the continued importance of correct condom-use in controlling the HIV epidemic and the limited availability of tools for assessing correct condom-use, methods for assessing condom-application skills, especially when direct observation is not feasible, are needed. Accordingly, in the context of a high-risk population (The Bahamas) for HIV, a 17-item scale—the Condom-use Skills Checklist (CUSC)—was developed for use among young adolescents and adults. The rationale and approach to developing the scale and some measures of internal consistency, construct validity, and criterion-related validity have been described. It is concluded that the scale offers a reasonable alternative to direct observation among older subjects and that further development may make it more useful among pre-adolescents

    Condom- use Skills Checklist: A Proxy for Assessing Condom-use Knowledge and Skills When Direct Observation Is Not Possible

    Get PDF
    Because of the continued importance of correct condom-use in controlling the HIV epidemic and the limited availability of tools for assessing correct condom-use, methods for assessing condom-application skills, especially when direct observation is not feasible, are needed. Accordingly, in the context of a high-risk population (The Bahamas) for HIV, a 17-item scale-the Condom-use Skills Checklist (CUSC)-was developed for use among young adolescents and adults. The rationale and approach to developing the scale and some measures of internal consistency, construct validity, and criterion-related validity have been described. It is concluded that the scale offers a reasonable alternative to direct observation among older subjects and that further development may make it more useful among pre-adolescents

    The Λp\bf{\Lambda p} interaction studied via femtoscopy in p + Nb reactions at sNN=3.18 GeV\mathbf{\sqrt{s_{NN}}=3.18} ~\mathrm{\bf{GeV}}

    Full text link
    We report on the first measurement of pΛp\Lambda and pppp correlations via the femtoscopy method in p+Nb reactions at sNN=3.18 GeV\mathrm{\sqrt{s_{NN}}=3.18} ~\mathrm{GeV}, studied with the High Acceptance Di-Electron Spectrometer (HADES). By comparing the experimental correlation function to model calculations, a source size for pppp pairs of r0,pp=2.02±0.01(stat)0.12+0.11(sys) fmr_{0,pp}=2.02 \pm 0.01(\mathrm{stat})^{+0.11}_{-0.12} (\mathrm{sys}) ~\mathrm{fm} and a slightly smaller value for pΛp\Lambda of r0,Λp=1.62±0.02(stat)0.08+0.19(sys) fmr_{0,\Lambda p}=1.62 \pm 0.02(\mathrm{stat})^{+0.19}_{-0.08}(\mathrm{sys}) ~\mathrm{fm} is extracted. Using the geometrical extent of the particle emitting region, determined experimentally with pppp correlations as reference together with a source function from a transport model, it is possible to study different sets of scattering parameters. The pΛp\Lambda correlation is proven sensitive to predicted scattering length values from chiral effective field theory. We demonstrate that the femtoscopy technique can be used as valid alternative to the analysis of scattering data to study the hyperon-nucleon interaction.Comment: 12 pages, 11 figure

    Passive Prophylactic Administration with a Single Dose of Anti-Fel d 1 Monoclonal Antibodies REGN1908-1909 in Cat Allergen-Induced Allergic Rhinitis: A Randomized, Double-blind, Placebo Controlled Trial

    Get PDF
    RATIONALE: Sensitization to Felis domesticus allergen 1 (Fel d 1) contributes to persistent allergic rhinitis and asthma. Existing treatment options for cat allergy, including allergen immunotherapy (AIT) are only moderately effective, and AIT has limited use due to safety concerns. OBJECTIVES: To explore the relationship among the pharmaokinteic, clinical, and immunological effects of REGN1908-1909 (anti-Fel d 1 monoclonal antibodies) in patients after treatment. METHODS: Patients received REGN1908-1909 (n=36) or placebo (n=37) in a phase 1b study. Fel d 1-induced basophil and IgE-facilitated allergen binding responses were evaluated at baseline and days 8, 29 and 85. Cytokine and chemokine levels in nasal fluids were measured. REGN1908-1909 inhibition of allergen-IgE binding in patient serum was evaluated. MEASUREMENTS AND MAIN RESULTS: Peak serum drug concentrations were concordant with maximal observed clinical response. The anti-Fel d 1 IgE/cat-dander IgE ratio in pretreatment serum correlated with Total Nasal Symptom Score improvement. The allergen neutralizing capacity of REGN1908-1909 was observed in serum and nasal fluid, and was detected in an inhibition assay. Type-2 cytokines (IL-4, IL-5 and IL-13) and chemokines (CCL17/TARC, CCL5/RANTES) in nasal fluid were inhibited in REGN1908-1909-treated patients compared to placebo (all P < 0.05); IL-13 and IL-5 levels correlated with TNSS improvement. Ex vivo assays demonstrated that REGN1908 and REGN1909 combined was more potent than each alone for inhibiting FcεRI- and FcεRII (CD23)-mediated allergic responses and subsequent T-cell activation. CONCLUSION: Single passive dose administration of Fel d 1-neutralizing IgG antibodies improved nasal symptoms in cat-allergic patients, and was underscored by suppression of FcεRI-, FcεRII- and Th2-mediated allergic responses. Clinical trial registration available at www.clinicaltrials.gov, ID: NCT02127801

    ECSA's Characteristics of Citizen Science: Explanation Notes

    Get PDF
    This explanation document provides an interpretation of and explanation for the characteristics document, which was kept short to make it useful to different stakeholders. In this document, the characteristics document is represented, with the original text in blue and an explanation in black

    Measurements of π±\pi^\pm, K±^\pm, p and pˉ\bar{\textrm{p}} spectra in proton-proton interactions at 20, 31, 40, 80 and 158 GeV/c with the NA61/SHINE spectrometer at the CERN SPS

    Get PDF
    Measurements of inclusive spectra and mean multiplicities of π±\pi^\pm, K±^\pm, p and pˉ\bar{\textrm{p}} produced in inelastic p+p interactions at incident projectile momenta of 20, 31, 40, 80 and 158 GeV/c (s=\sqrt{s} = 6.3, 7.7, 8.8, 12.3 and 17.3 GeV, respectively) were performed at the CERN Super Proton Synchrotron using the large acceptance NA61/SHINE hadron spectrometer. Spectra are presented as function of rapidity and transverse momentum and are compared to predictions of current models. The measurements serve as the baseline in the NA61/SHINE study of the properties of the onset of deconfinement and search for the critical point of strongly interacting matter

    Multiplicity and transverse momentum fluctuations in inelastic proton-proton interactions at the CERN Super Proton Synchrotron

    Get PDF
    Measurements of multiplicity and transverse momentum fluctuations of charged particles were performed in inelastic p+p interactions at 20, 31, 40, 80 and 158 GeV/c beam momentum. Results for the scaled variance of the multiplicity distribution and for three strongly intensive measures of multiplicity and transverse momentum fluctuations \$\Delta[P_{T},N]\$, \$\Sigma[P_{T},N]\$ and \$\Phi_{p_T}\$ are presented. For the first time the results on fluctuations are fully corrected for experimental biases. The results on multiplicity and transverse momentum fluctuations significantly deviate from expectations for the independent particle production. They also depend on charges of selected hadrons. The string-resonance Monte Carlo models EPOS and UrQMD do not describe the data. The scaled variance of multiplicity fluctuations is significantly higher in inelastic p+p interactions than in central Pb+Pb collisions measured by NA49 at the same energy per nucleon. This is in qualitative disagreement with the predictions of the Wounded Nucleon Model. Within the statistical framework the enhanced multiplicity fluctuations in inelastic p+p interactions can be interpreted as due to event-by-event fluctuations of the fireball energy and/or volume.Comment: 18 pages, 12 figure
    corecore