193 research outputs found

    hbim in a semantic 3d gis database

    Get PDF
    Abstract. This work describes the different attempts and the consequent results derived from the integration of an HBIM model into an already structured spatial database (DB) and its 3D visualisation in a GIS project.This study is connected to the European ResCult (Increasing Resilience of Cultural Heritage) project where a DB for multiscale analyses was defined. To test the methodology proposed, the case study of Santa Maria dei Miracoli church in Venice was chosen since it represents a complex architectural heritage piece in a risk zone, it has been subject to a vast restoration intervention in the recent past but a digital documentation and model concerning it was missing.The 3D model of the church was structured in Revit as a HBIM, with the association of different kind of information and data related to the architectural elements by means of 'shared parameters' and 'system families'. This procedure allows to reach an even higher Level of Detail (LOD4), but lead to some issues related to the semantic and software interoperability. To solve these problems the existing DB for the resilience of cultural heritage was extended adding a new entity representing the architectural elements designed in the BIM project.The aim of the test is to understand how the data and attributes inserted in the HBIM are converted and handled when dealing with a GIS DB, stepping from the IFC to the CityGML standard, through the FME software.</p

    effectiveness of aquatic therapy in post-surgery rehabilitation of the rotator cuff

    Get PDF
    Introduction: rotator cuff injuries very often require surgical repair and subsequent rehabilitation. The aim of this study was to compare the effectiveness of a traditional and an aquatic post-surgery rehabilitation program of the rotator cuff in 20 adult (60±5y) patients. Methods:patients were randomly assigned to a traditional (TR; n=10) and to an aquatic (WR; n=10) rehabilitation group. Both programs started 15 days after the surgery, lasted 3 months (3 times-a-week), and consisted in passive mobilization followed by strengthening exercises. The only WR group underwent to an adjunctive aquatic mobilization program. Before (pre-intervention) and after (post-intervention) the programs, patients underwent the following assessments: shoulder range of motion (ROM), in both flexion and extra rotation positions; pain perception (visual analogue scale); simple shoulder test. Results: pre vs. post-intervention results were compared in each group by means of a dependent-samples t-Test on each variables. An independent-samples t-Test was used to analyze pre-intervention differences between TR and WR groups; since no significant differences were found, the same test was used to analyze post-intervention differences. Pre- vs post-intervention results showed significant improvements in all variables in both groups (p 0,005) Discussion: although the water-based program did not result more effective than the traditional program at the end of the three months, the aquatic rehabilitation seemed to improve shoulder ROM faster than the traditional one and to be better tolerated by the patients. It’s authors’ opinion that both evidences may increase the adherence to the program during the rest of the rehabilitation programUniversidad de Málaga. Campus de Excelencia Internacional Andalucía Tech

    Economic impact of remote monitoring on ordinary follow-up of implantable cardioverter defibrillators as compared with conventional in-hospital visits: a single-center prospective and randomized study

    Get PDF
    Few data are available on actual follow-up costs of remote monitoring (RM) of implantable defibrillators (ICD). Our study aimed at assessing current direct costs of 1-year ICD follow-up based on RM compared with conventional quarterly in-hospital follow-ups. Methods and results Patients (N=233) with indications for ICD were consecutively recruited and randomized at implant to be followed up for 1 year with standard quarterly inhospital visits or by RM with one in-hospital visit at 12 months, unless additional in-hospital visits were required due to specific patient conditions or RM alarms. Costs were calculated distinguishing between provider and patient costs, excluding RM device and service cost. The frequency of scheduled in-hospital visits was lower in the RM group than in the control arm. Follow-up required 47 min per patient/year in the RM arm versus 86 min in the control arm (p=0.03) for involved physicians, generating cost estimates for the provider of USD 45 and USD 83 per patient/- year, respectively. Costs for nurses were comparable. Overall, the costs associated with RM and standard follow-up were USD 103±27 and 154±21 per patient/year, respectively (p=0.01). RM was cost-saving for the patients: USD 97±121 per patient/year in the RM group versus 287± 160 per patient/year (p=0.0001). Conclusion The time spent by the hospital staff was significantly reduced in the RM group. If the costs for the device and service are not charged to patients or the provider, patients could save about USD 190 per patient/year while the hospital could save USD 51 per patient/year

    RIP1-HAT1-SirT complex identification and targeting in treatment and prevention of cancer

    Get PDF
    Purpose: Alteration in cell death is a hallmark of cancer. A functional role regulating survival, apoptosis, and necroptosis has been attributed to RIP1/3 complexes.Experimental Design: We have investigated the role of RIP1 and the effects of MC2494 in cell death induction, using different methods as flow cytometry, transcriptome analysis, immunoprecipitation, enzymatic assays, transfections, mutagenesis, and in vivo studies with different mice models.Results: Here, we show that RIP1 is highly expressed in cancer, and we define a novel RIP1/3-SIRT1/2-HAT1/4 complex. Mass spectrometry identified five acetylations in the kinase and death domain of RIP1. The novel characterized pan-SIRT inhibitor, MC2494, increases RIP1 acetylation at two additional sites in the death domain. Mutagenesis of the acetylated lysine decreases RIP1-dependent cell death, suggesting a role for acetylation of the RIP1 complex in cell death modulation. Accordingly, MC2494 displays tumor-selective potential in vitro, in leukemic blasts ex vivo, and in vivo in both xenograft and allograft cancer models. Mechanistically, MC2494 induces bona fide tumor-restricted acetylated RIP1/caspase-8-mediated apoptosis. Excitingly, MC2494 displays tumor-preventive activity by blocking 7,12-dimethylbenz(α)anthracene-induced mammary gland hyperproliferation in vivoConclusions: These preventive features might prove useful in patients who may benefit from a recurrence-preventive approach with low toxicity during follow-up phases and in cases of established cancer predisposition. Thus, targeting the newly identified RIP1 complex may represent an attractive novel paradigm in cancer treatment and prevention

    The imaging properties of the Gas Pixel Detector as a focal plane polarimeter

    Full text link
    X-rays are particularly suited to probe the physics of extreme objects. However, despite the enormous improvements of X-ray Astronomy in imaging, spectroscopy and timing, polarimetry remains largely unexplored. We propose the photoelectric polarimeter Gas Pixel Detector (GPD) as an instrument candidate to fill the gap of more than thirty years of lack of measurements. The GPD, in the focus of a telescope, will increase the sensitivity of orders of magnitude. Moreover, since it can measure the energy, the position, the arrival time and the polarization angle of every single photon, allows to perform polarimetry of subsets of data singled out from the spectrum, the light curve or the image of source. The GPD has an intrinsic very fine imaging capability and in this work we report on the calibration campaign carried out in 2012 at the PANTER X-ray test facility of the Max-Planck-Institut f\"ur extraterrestrische Physik of Garching (Germany) in which, for the first time, we coupled it to a JET-X optics module with a focal length of 3.5 m and an angular resolution of 18 arcsec at 4.5 keV. This configuration was proposed in 2012 aboard the X-ray Imaging Polarimetry Explorer (XIPE) in response to the ESA call for a small mission. We derived the imaging and polarimetric performance for extended sources like Pulsar Wind Nebulae and Supernova Remnants as case studies for the XIPE configuration, discussing also possible improvements by coupling the detector with advanced optics, having finer angular resolution and larger effective area, to study with more details extended objects.Comment: Accepted for publication in The Astrophysical Journal Supplemen

    Reproducibility of acute pulmonary vein isolation guided by the ablation index.

    Get PDF
    BACKGROUND: Atrial fibrillation (AF) ablation outcome is still operator dependent. Ablation Index (AI) is a new lesion quality marker that has been demonstrated to allow acute durable pulmonary vein (PV) isolation followed by a high single-procedure arrhythmia-free survival. This prospective, multicenter study was designed to evaluate the reproducibility of acute PV isolation guided by the AI. METHODS: A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV encircling and were divided in four study groups according to operator preference in choosing the ablation catheter (a contact force [ST] or contact force surround flow [STSF] catheter) and the AI setting (330 at posterior and 450 at anterior wall or 380 at posterior and 500 at anterior wall). Radiofrequency was delivered targeting interlesion distance ≤6 mm. RESULTS: The rate of first-pass PV isolation (ST330 90 ± 16%, ST380 87 ± 19%, STSF330 90 ± 17%, STSF380 91 ± 15%, P = .585) was similar among the four study groups, whereas procedure (ST330 129 ± 44 minutes, ST380 144 ± 44 minutes, STSF330 120 ± 72 minutes, STSF380 125 ± 73 minutes, P < .001) and fluoroscopy time (ST330 542 ± 285 seconds, ST380 540 ± 416 seconds, STSF330 257 ± 356 seconds, STSF380 379 ± 454 seconds, P < 0.001) significantly differed. The difference in the rate of first-pass isolation was not statistical different (P = .06) among the 12 operators that performed at least 15 procedures. CONCLUSIONS: An ablation protocol respecting strict criteria for contiguity and quality lesion results in high and comparable rate of acute PV isolation among operator performing ablation with different catheters, AI settings, procedure, and fluoroscopy times
    • …
    corecore