271 research outputs found
Search for Event Rate Modulation in XENON100 Electronic Recoil Data
We have searched for periodic variations of the electronic recoil event rate
in the (2-6) keV energy range recorded between February 2011 and March 2012
with the XENON100 detector, adding up to 224.6 live days in total. Following a
detailed study to establish the stability of the detector and its background
contributions during this run, we performed an un-binned profile likelihood
analysis to identify any periodicity up to 500 days. We find a global
significance of less than 1 sigma for all periods suggesting no statistically
significant modulation in the data. While the local significance for an annual
modulation is 2.8 sigma, the analysis of a multiple-scatter control sample and
the phase of the modulation disfavor a dark matter interpretation. The
DAMA/LIBRA annual modulation interpreted as a dark matter signature with
axial-vector coupling of WIMPs to electrons is excluded at 4.8 sigma.Comment: 6 pages, 4 figure
Employer requirements and COVID-19 vaccination and attitudes among healthcare personnel in the U.S.: Findings from National Immunization Survey Adult COVID Module, August – September 2021
Introduction: Employer vaccination requirements have been used to increase vaccination uptake among healthcare personnel (HCP). In summer 2021, HCP were the group most likely to have employer requirements for COVID-19 vaccinations as healthcare facilities led the implementation of such requirements. This study examined the association between employer requirements and HCP's COVID-19 vaccination status and attitudes about the vaccine. Methods: Participants were a national representative sample of United States (US) adults who completed the National Immunization Survey Adult COVID Module (NIS-ACM) during August–September 2021. Respondents were asked about COVID-19 vaccination and intent, requirements for vaccination, place of work, attitudes surrounding vaccinations, and sociodemographic variables. This analysis focused on HCP respondents. We first calculated the weighted proportion reporting COVID-19 vaccination for HCP by sociodemographic variables. Then we computed unadjusted and adjusted prevalence ratios for vaccination coverage and key indicators on vaccine attitudes, comparing HCP based on individual self-report of vaccination requirements. Results: Of 12,875 HCP respondents, 41.5% reported COVID-19 vaccination employer requirements. Among HCP with vaccination requirements, 90.5% had been vaccinated against COVID-19, as compared to 73.3% of HCP without vaccination requirements—a pattern consistent across sociodemographic groups. Notably, the greatest differences in uptake between HCP with and without employee requirements were seen in sociodemographic subgroups with the lowest vaccination uptake, e.g., HCP aged 18–29 years, HCP with high school or less education, HCP living below poverty, and uninsured HCP. In every sociodemographic subgroup examined, vaccine uptake was more equitable among HCP with vaccination requirements than in HCP without. Finally, HCP with vaccination requirements were also more likely to express confidence in the vaccine's safety (68.3% vs. 60.1%) and importance (89.6% vs 79.6%). Conclusion: In a large national US sample, employer requirements were associated with higher and more equitable HCP vaccination uptake across all sociodemographic groups examined. Our findings suggest that employer requirements can contribute to improving COVID-19 vaccination coverage, similar to patterns seen for other vaccines
Search for Two-Neutrino Double Electron Capture of Xe with XENON100
Two-neutrino double electron capture is a rare nuclear decay where two
electrons are simultaneously captured from the atomic shell. For Xe
this process has not yet been observed and its detection would provide a new
reference for nuclear matrix element calculations. We have conducted a search
for two-neutrino double electron capture from the K-shell of Xe using
7636 kgd of data from the XENON100 dark matter detector. Using a
Bayesian analysis we observed no significant excess above background, leading
to a lower 90 % credibility limit on the half-life
yr. We also evaluated the sensitivity of the XENON1T experiment, which is
currently being commissioned, and find a sensitivity of
yr after an exposure of 2 tyr.Comment: 6 pages, 4 figure
Removing krypton from xenon by cryogenic distillation to the ppq level
The XENON1T experiment aims for the direct detection of dark matter in a
cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired
sensitivity, the background induced by radioactive decays inside the detector
has to be sufficiently low. One major contributor is the -emitter
Kr which is an intrinsic contamination of the xenon. For the XENON1T
experiment a concentration of natural krypton in xenon Kr/Xe < 200
ppq (parts per quadrillion, 1 ppq = 10 mol/mol) is required. In this
work, the design of a novel cryogenic distillation column using the common
McCabe-Thiele approach is described. The system demonstrated a krypton
reduction factor of 6.410 with thermodynamic stability at process
speeds above 3 kg/h. The resulting concentration of Kr/Xe < 26 ppq
is the lowest ever achieved, almost one order of magnitude below the
requirements for XENON1T and even sufficient for future dark matter experiments
using liquid xenon, such as XENONnT and DARWIN
Search for dinucleon decay into pions at Super-Kamiokande
A search for dinucleon decay into pions with the Super-Kamiokande detector
has been performed with an exposure of 282.1 kiloton-years. Dinucleon decay is
a process that violates baryon number by two units. We present the first search
for dinucleon decay to pions in a large water Cherenkov detector. The modes
O C, O
N, and O
O are investigated. No significant excess in the
Super-Kamiokande data has been found, so a lower limit on the lifetime of the
process per oxygen nucleus is determined. These limits are:
years,
years, and
years. The lower
limits on each mode are about two orders of magnitude better than previous
limits from searches for dinucleon decay in iron.Comment: 20 pages, 17 figures. Accepted for publication in Physical Review D
on March 30, 201
Systematic review of cost and cost-effectiveness of different TB-screening strategies
<p>Abstract</p> <p>Background</p> <p>Interferon-γ release assays (IGRAs) for TB have the potential to replace the tuberculin skin test (TST) in screening for latent tuberculosis infection (LTBI). The higher per-test cost of IGRAs may be compensated for by lower post-screening costs (medical attention, chest x-rays and chemoprevention), given the higher specificity of the new tests as compared to that of the conventional TST. We conducted a systematic review of all publications that have addressed the cost or cost-effectiveness of IGRAs. The objective of this report was to undertake a structured review and critical appraisal of the methods used for the model-based cost-effectiveness analysis of TB screening programmes.</p> <p>Methods</p> <p>Using Medline and Embase, 75 publications that contained the terms "IGRA", "tuberculosis" and "cost" were identified. Of these, 13 were original studies on the costs or cost-effectiveness of IGRAs.</p> <p>Results</p> <p>The 13 relevant studies come from five low-to-medium TB-incidence countries. Five studies took only the costs of screening into consideration, while eight studies analysed the cost-effectiveness of different screening strategies. Screening was performed in high-risk groups: close contacts, immigrants from high-incidence countries and healthcare workers. Two studies used the T-SPOT.TB as an IGRA and the other studies used the QuantiFERON-TB Gold and/or Gold In-Tube test. All 13 studies observed a decrease in costs when the IGRAs were used. Six studies compared the use of an IGRA as a test to confirm a positive TST (TST/IGRA strategy) to the use of an IGRA-only strategy. In four of these studies, the two-step strategy and in two the IGRA-only strategy was more cost-effective. Assumptions about TST specificity and progression risk after a positive test had the greatest influence on determining which IGRA strategy was more cost-effective.</p> <p>Conclusion</p> <p>The available studies on cost-effectiveness provide strong evidence in support of the use of IGRAs in screening risk groups such as HCWs, immigrants from high-incidence countries and close contacts. So far, only two studies provide evidence that the IGRA-only screening strategy is more cost-effective.</p
- …