179 research outputs found
Wakefield-Induced Ionization injection in beam-driven plasma accelerators
We present a detailed analysis of the features and capabilities of
Wakefield-Induced Ionization (WII) injection in the blowout regime of beam
driven plasma accelerators. This mechanism exploits the electric wakefields to
ionize electrons from a dopant gas and trap them in a well-defined region of
the accelerating and focusing wake phase, leading to the formation of
high-quality witness-bunches [Martinez de la Ossa et al., Phys. Rev. Lett. 111,
245003 (2013)]. The electron-beam drivers must feature high-peak currents
() and a duration comparable to the plasma
wavelength to excite plasma waves in the blowout regime and enable WII
injection. In this regime, the disparity of the magnitude of the electric field
in the driver region and the electric field in the rear of the ion cavity
allows for the selective ionization and subsequent trapping from a narrow phase
interval. The witness bunches generated in this manner feature a short duration
and small values of the normalized transverse emittance (). In addition, we show that the amount of injected
charge can be adjusted by tuning the concentration of the dopant gas species,
which allows for controlled beam loading and leads to a reduction of the total
energy spread of the witness beams. Electron bunches, produced in this way,
fulfil the requirements to drive blowout regime plasma wakes at a higher
density and to trigger WII injection in a second stage. This suggests a
promising new concept of self-similar staging of WII injection in steps with
increasing plasma density, giving rise to the potential of producing electron
beams with unprecedented energy and brilliance from plasma-wakefield
accelerators
ArgoNeuT and the Neutrino-Argon Charged Current Quasi-Elastic Cross Section
ArgoNeuT, a Liquid Argon Time Projection Chamber in the NuMI beamline at
Fermilab, has recently collected thousands of neutrino and anti-neutrino events
between 0.1 and 10 GeV. The experiment will, among other things, measure the
cross section of the neutrino and anti-neutrino Charged Current Quasi-Elastic
interaction and analyze the vertex activity associated with such events. These
topics are discussed along with ArgoNeuT's automated reconstruction software,
currently capable of fully reconstructing the muon and finding the event vertex
in neutrino interactions.Comment: 6 pages, 4 figures, presented at the International Nuclear Physics
Conference, Vancouver, Canada, July 4-9, 2010, to be published in Journal of
Physics: Conference Series (JPCS
The FLASHForward Facility at DESY
The FLASHForward project at DESY is a pioneering plasma-wakefield
acceleration experiment that aims to produce, in a few centimetres of ionised
hydrogen, beams with energy of order GeV that are of quality sufficient to be
used in a free-electron laser. The plasma wave will be driven by high-current
density electron beams from the FLASH linear accelerator and will explore both
external and internal witness-beam injection techniques. The plasma is created
by ionising a gas in a gas cell with a multi-TW laser system, which can also be
used to provide optical diagnostics of the plasma and electron beams due to the
<30 fs synchronisation between the laser and the driving electron beam. The
operation parameters of the experiment are discussed, as well as the scientific
program.Comment: 19 pages, 9 figure
Energy-Spread Preservation and High Efficiency in a Plasma-Wakefield Accelerator
Energy-efficient plasma-wakefield acceleration of particle bunches with low energy spread is a promising path to realizing compact free-electron lasers and particle colliders. High efficiency and low energy spread can be achieved simultaneously by strong beam loading of plasma wakefields when accelerating bunches with carefully tailored current profiles [M. Tzoufras et al., Phys. Rev. Lett. 101, 145002 (2008)PRLTAO0031-900710.1103/PhysRevLett.101.145002]. We experimentally demonstrate such optimal beam loading in a nonlinear electron-driven plasma accelerator. Bunches with an initial energy of 1 GeV were accelerated by 45 MeV with an energy-transfer efficiency of (42±4)% at a gradient of 1.3ââGV/m while preserving per-mille energy spreads with full charge coupling, demonstrating wakefield flattening at the few-percent level
Cosmological anti-deSitter space-times and time-dependent AdS/CFT correspondence
We study classes of five-dimensional cosmological solutions with negative
curvature, which are obtained from static solutions by an exchange of a spatial
and temporal coordinate, and in some cases by an analytic continuation. Such
solutions provide a suitable laboratory to address the time-dependent AdS/CFT
correspondence. For a specific example we address in detail the calculation of
the boundary stress-energy and the Wilson line and find disagreement with the
standard AdS/CFT correspondence. We trace these discrepancies to the
time-dependent effects, such as particle creation, which we further study for
specific backgrounds. We also identify specific time-dependent backgrounds that
reproduce the correct conformal anomaly. For such backgrounds the calculation
of the Wilson line in the adiabatic approximation indicates only a Coulomb
repulsion.Comment: LaTeX file, 47 pages, discussion is extended, version to appear in
PR
Possible Origin of Fermion Chirality and Gut Structure From Extra Dimensions
The fundamental chiral nature of the observed quarks and leptons and the
emergence of the gauge group itself are most puzzling aspects of the standard
model. Starting from general considerations of topological properties of gauge
field configurations in higher space-time dimensions, it is shown that the
existence of non-trivial structures in ten dimensions would determine a class
of models corresponding to a grand unified GUT structure with complex fermion
representations with respect to . The
discussion is carried out within the framework of string theories with
characteristic energy scales below the Planck mass. Avoidance of topological
obstructions upon continuous deformation of field configurations leads to
global chiral symmetry breaking of the underlying fundamental theory, imposes
rigorous restrictions on the structure of the vacuum and space-time itself and
determines uniquely the gauge structure and matter content.Comment: final version to appear in Phys. Rev.
Overview of Plasma Lens Experiments and Recent Results at SPARC_LAB
Beam injection and extraction from a plasma module is still one of the
crucial aspects to solve in order to produce high quality electron beams with a
plasma accelerator. Proper matching conditions require to focus the incoming
high brightness beam down to few microns size and to capture a high divergent
beam at the exit without loss of beam quality. Plasma-based lenses have proven
to provide focusing gradients of the order of kT/m with radially symmetric
focusing thus promising compact and affordable alternative to permanent magnets
in the design of transport lines. In this paper an overview of recent
experiments and future perspectives of plasma lenses is reported
Bose-Einstein correlations in hadron-pairs from lepto-production on nuclei ranging from hydrogen to xenon
Bose-Einstein correlations of like-sign charged hadrons produced in
deep-inelastic electron and positron scattering are studied in the HERMES
experiment using nuclear targets of H, H, He, He, N, Ne, Kr,
and Xe. A Gaussian approach is used to parametrize a two-particle correlation
function determined from events with at least two charged hadrons of the same
sign charge. This correlation function is compared to two different empirical
distributions that do not include the Bose-Einstein correlations. One
distribution is derived from unlike-sign hadron pairs, and the second is
derived from mixing like-sign pairs from different events. The extraction
procedure used simulations incorporating the experimental setup in order to
correct the results for spectrometer acceptance effects, and was tested using
the distribution of unlike-sign hadron pairs. Clear signals of Bose-Einstein
correlations for all target nuclei without a significant variation with the
nuclear target mass are found. Also, no evidence for a dependence on the
invariant mass W of the photon-nucleon system is found when the results are
compared to those of previous experiments
Sex and gender differences in acute stroke care: metrics, access to treatment and outcome. A territorial analysis of the Stroke Code System of Catalonia
Introduction: Previous studies have reported differences in the management and outcome of women stroke patients in comparison with men. We aim to analyze sex and gender differences in the medical assistance, access to treatment and outcome of acute stroke patients in Catalonia. Patients and methods: Data were obtained from a prospective population-based registry of stroke code activations in Catalonia (CICAT) from January/2016 to December/2019. The registry includes demographic data, stroke severity, stroke subtype, reperfusion therapy, and time workflow. Centralized clinical outcome at 90 days was assessed in patients receiving reperfusion therapy. Results: A total of 23,371 stroke code activations were registered (54% men, 46% women). No differences in prehospital time metrics were observed. Women more frequently had a final diagnosis of stroke mimic, were older and had a previous worse functional situation. Among ischemic stroke patients, women had higher stroke severity and more frequently presented proximal large vessel occlusion. Women received more frequently reperfusion therapy (48.2% vs 43.1%, p < 0.001). Women tended to present a worse outcome at 90 days, especially for the group receiving only IVT (good outcome 56.7% vs 63.8%; p < 0.001), but not for the group of patients treated with IVT + MT or MT alone, although sex was not independently associated with clinical outcome in logistic regression analysis (OR 1.07; 95% CI, 0.94â1.23; p = 0.27) nor in the analysis after matching using the propensity score (OR 1.09; 95% CI, 0.97â1.22). Discussion and conclusion: We found some differences by sex in that acute stroke was more frequent in older women and the stroke severity was higher. We found no differences in medical assistance times, access to reperfusion treatment and early complications. Worse clinical outcome at 90 days in women was conditioned by stroke severity and older age, but not by sex itself
- âŠ