    Understanding adaptive gait in lower-limb amputees: insights from multivariate analyses.

    Get PDF
    BACKGROUND: In this paper we use multivariate statistical techniques to gain insights into how adaptive gait involving obstacle crossing is regulated in lower-limb amputees compared to able-bodied controls, with the aim of identifying underlying characteristics that differ between the two groups and consequently highlighting gait deficits in the amputees. METHODS: Eight unilateral trans-tibial amputees and twelve able-bodied controls completed adaptive gait trials involving negotiating various height obstacles; with amputees leading with their prosthetic limb. Spatiotemporal variables that are regularly used to quantify how gait is adapted when crossing obstacles were determined and subsequently analysed using multivariate statistical techniques. RESULTS AND DISCUSSION: There were fundamental differences in the adaptive gait between the two groups. Compared to controls, amputees had a reduced approach velocity, reduced foot placement distance before and after the obstacle and reduced foot clearance over it, and reduced lead-limb knee flexion during the step following crossing. Logistic regression analysis highlighted the variables that best distinguished between the gait of the two groups and multiple regression analysis (with approach velocity as a controlling factor) helped identify what gait adaptations were driving the differences seen in these variables. Getting closer to the obstacle before crossing it appeared to be a strategy to ensure the heel of the lead-limb foot passed over the obstacle prior to the foot being lowered to the ground. Despite adopting such a heel clearance strategy, the lead-foot was positioned closer to the obstacle following crossing, which was likely a result of a desire to attain a limb/foot angle and orientation at instant of landing that minimised loads on the residuum (as evidenced by the reduced lead-limb knee flexion during the step following crossing). These changes in foot placement meant the foot was in a different part of swing at point of crossing and this explains why foot clearance was considerably reduced in amputees. CONCLUSIONS: These results highlight that trans-tibial amputees use quite different gait adaptations to cross obstacles compared with controls (at least when leading with their prosthetic limb), indicating they are governed by different constraints; seemingly related to how they land on/load their prosthesis after crossing the obstacle

    Which prosthetic foot to prescribe?

    Get PDF
    Introduction: Clinicians typically use findings from cohort studies to objectively inform judgements regarding the potential (dis)advantages of prescribing a new prosthetic device. However, before finalising prescription a clinician will typically ask a patient to 'try out' a change of prosthetic device while the patient is at the clinic. Observed differences in gait when using the new device should be the result of the device’s mechanical function, but could also conceivably be due to patient related factors which can change from day-to-day and can thus make device comparisons unreliable. To determine whether a device’s mechanical function consistently has a more meaningful impact on gait than patient-related factors, the present study undertook quantitative gait analyses of a trans-tibial amputee walking using two different foot-ankle devices on two occasions over a year apart. If the observed differences present between devices, established using quantitative gait analysis, were in the same direction and of similar magnitude on each of the two occasions, this would indicate that device-related factors were more important than patient-related factors. Methods: One adult male with a unilateral trans-tibial amputation completed repeated walking trials using two different prosthetic foot devices on two separate occasions, 14 months apart. Walking speed and sagittal plane joint kinematics and kinetics for both limbs were assessed on each occasion. Clinically meaningful differences in these biomechanical outcome variables were defined as those with an effect size difference (d) between prosthetic conditions of at least 0.4 (i.e. 'medium' effect size). Results: Eight variables namely, walking speed, prosthetic 'ankle' peak plantar- and dorsi-flexion and peak positive power, and residual knee loading response flexion, peak stance-phase extension and flexion moments and peak negative power, displayed clinically meaningful differences (d > 0.4) between foot devices during the first session. All eight of these showed similar effect size differences during the second session despite the participant being heavier and older. Conclusions: Findings suggest that a prosthetic device's mechanical function consistently has a more meaningful impact on gait than patient-related factors. These findings support the current clinical practice of making decisions regarding prosthetic prescription for an individual, based on a single session evaluation of their gait using two different devices. However, to confirm this conclusion, a case series using the same approach as the present study could be undertaken

    Manipulation of visual biofeedback during gait with a time delayed adaptive Virtual Mirror Box.

    Get PDF
    A mirror placed in the mid-sagittal plane of the body has been used to reduce phantom limb pain and improve movement function in medical conditions characterised by asymmetrical movement control. The mirrored illusion of unimpaired limb movement during gait might enhance the effect, but a physical mirror is only capable of showing parallel movement of limbs in real time typically while sitting. We aimed to overcome the limitations of physical mirrors by developing and evaluating a Virtual Mirror Box which delays the mirrored image of limbs during gait to ensure temporal congruency with the impaired physical limb

    Individuals with unilateral transtibial amputation exhibit reduced accuracy and precision during a targeted stepping task

    Get PDF
    Accurate foot placement is important for dynamic balance during activities of daily living. Disruption of sensory information and prosthetic componentry characteristics may result in increased locomotor task difficulty for individuals with lower limb amputation. This study investigated the accuracy and precision of prosthetic and intact foot placement during a targeted stepping task in individuals with unilateral transtibial amputation (IUTAs; N=8, 47±13 yrs), compared to the preferred foot of control participant’s (N=8, 33±15 yrs). Participants walked along a 10-metre walkway, placing their foot into a rectangular floor-based target with dimensions normalised to a percentage of participant’s foot length and width; ‘standard’ = 150%x150%, ‘wide’ = 150%x200%, ‘long’ = 200%x150%. Foot placement accuracy (relative distance between foot and target centre), precision (between-trial variability), and foot-reach kinematics were determined for each limb and target, using three-dimensional motion capture. A significant foot-by-target interaction revealed less mediolateral foot placement accuracy for IUTAs in the wide target, which was significantly less accurate for the intact (28±12mm) compared to prosthetic foot (16±14mm). Intact peak foot velocity (4.6±0.8m.s-1) was greater than the prosthetic foot (4.5±0.8m.s-1) for all targets. Controls were more accurate and precise than IUTAs, regardless of target size. Less accurate and precise intact foot placement in IUTAs, coupled with a faster moving intact limb, is likely due to several factors including reduced proprioceptive feedback and active control during prosthetic limb single stance. This could affect activities of daily living where foot placement is critical, such as negotiating cluttered travel paths or obstacles whilst maintaining balance

    The effects of walking speed on minimum toe clearance and on the temporal relationship between minimum clearance and peak swing-foot velocity in unilateral trans-tibial amputees

    Get PDF
    yesBackground: Minimum toe clearance is a critical gait event because it coincides with peak forward velocity of the swing foot, and thus, there is an increased risk of tripping and falling. Trans-tibial amputees have increased risk of tripping compared to able-bodied individuals. Assessment of toe clearance during gait is thus clinically relevant. In able-bodied gait, minimum toe clearance increases with faster walking speeds, and it is widely reported that there is synchronicity between when peak swing-foot velocity and minimum toe clearance occur. There are no such studies involving lower-limb amputees. Objectives: To determine the effects of walking speed on minimum toe clearance and on the temporal relationship between clearance and peak swing-foot velocity in unilateral trans-tibial amputees. Study design: Cross-sectional. Methods: A total of 10 trans-tibial participants walked at slow, customary and fast speeds. Minimum toe clearance and the timings of minimum toe clearance and peak swing-foot velocity were determined and compared between intact and prosthetic sides. Results: Minimum toe clearance was reduced on the prosthetic side and, unlike on the intact side, did not increase with walking speed increase. Peak swing-foot velocity consistently occurred (~0.014 s) after point of minimum toe clearance on both limbs across all walking speeds, but there was no significant difference in the toe–ground clearance between the two events. Conclusion: The absence of speed related increases in minimum toe clearance on the prosthetic side suggests that speed related modulation of toe clearance for an intact limb typically occurs at the swing-limb ankle. The temporal consistency between peak foot velocity and minimum toe clearance on each limb suggests that swing-phase inter-segmental coordination is unaffected by trans-tibial amputation. Clinical relevance The lack of increase in minimum toe clearance on the prosthetic side at higher walking speeds may potentially increase risk of tripping. Findings indicate that determining the instant of peak swing-foot velocity will also consistently identify when/where minimum toe clearance occurs

    Spring-mass behavioural adaptations to acute changes in prosthetic blade stiffness during submaximal running in unilateral transtibial prosthesis users

    Get PDF
    Background: Individuals with lower-limb amputation can use running specific prostheses (RSP) that store and then return elastic energy during stance. However, it is unclear whether varying the stiffness category of the same RSP affects spring-mass behaviour during self-selected, submaximal speed running in individuals with unilateral transtibial amputation. Research question: The current study investigates how varying RSP stiffness affects limb stiffness, running performance, and associated joint kinetics in individuals with a unilateral transtibial amputation. Methods: Kinematic and ground reaction force data were collected from eight males with unilateral transtibial amputation who ran at self-selected submaximal speeds along a 15 m runway in three RSP stiffness conditions; recommended habitual stiffness (HAB) and, following 10-minutes of familiarisation, stiffness categories above (+1) and below (-1) the HAB. Stance-phase centre of mass velocity, contact time, limb stiffness’ and joint/RSP work were computed for each limb across RSP stiffness conditions. Results: With increased RSP stiffness, prosthetic limb stiffness increased, whilst intact limb stiffness decreased slightly (p<0.03). Centre of mass forward velocity during stance-phase (p<0.02) and contact time (p<0.04) were higher in the intact limb and lower in the prosthetic limb but were unaffected by RSP stiffness. Intact limb hip joint positive work increased for both the +1 and -1 conditions but remained unchanged across conditions in the prosthetic limb (p<0.02). Significance: In response to changes in RSP stiffness, there were acute increased mechanical demands on the intact limb, reflecting a reliance on the intact limb during running. However, overall running speed was unaffected, suggesting participants acutely adapted to an RSP of a non-prescribed stiffness

    Individuals with unilateral transtibial amputation and lower activity levels walk more quickly when using a hydraulically articulating versus rigidly attached prosthetic ankle-foot device

    Get PDF
    Introduction: Prosthetic ankle-foot devices incorporating a hydraulic articulation between the pylon and prosthetic foot have been shown to be beneficial to the gait of more active individuals with unilateral transtibial amputation (UTA). However, the functional benefits of using hydraulic ankle-foot devices to less active individuals with UTA are yet to be determined. The aim of the current study was to investigate the effects on gait performance of using a non-ESR foot with a hydraulic attachment, compared to an identical, rigidly attached foot during overground walking in less active individuals with UTA. Materials and Methods: Kinematic and kinetic data were recorded while five individuals with UTA, deemed K2 activity level by their prescribing physician, performed two-minute walk tests (2MWT) and ten overground gait trials, in two conditions; using a hydraulically articulating ankle foot device (HYD) and using a rigidly attached ankle foot device (RIG). Results: Walking speed during the 2MWT was increased by 6.5% on average, in the HYD (1.07 m/s) condition, compared to the RIG (1.01 m/s) condition (Cohen’s d = 0.4). Participants displayed more symmetrical inter-limb loading (d = 0.8), increased minimum forward centre of pressure velocity (d = 0.8), increased peak shank rotational velocity (d = 1.0) and decreased prosthetic energy efficiency (d = 0.7) when using the HYD compared to RIG device. Conclusions: Individuals with lower activity levels walk faster and therefore further when, using a foot with a hydraulically articulating attachment, in comparison to a rigid attachment. A reduced braking effect in early stance phase, as a result of the action of the hydraulic component present in the articulating attachment, partially explains the improvement in walking performance

    Energy cost of ambulation in trans-tibial amputees using a dynamic-response foot with hydraulic versus rigid 'ankle': insights from body centre of mass dynamics.

    Get PDF
    BACKGROUND:Previous research has shown that use of a dynamic-response prosthetic foot (DRF) that incorporates a small passive hydraulic ankle device (hyA-F), provides certain biomechanical benefits over using a DRF that has no ankle mechanism (rigA-F). This study investigated whether use of a hyA-F in unilateral trans-tibial amputees (UTA) additionally provides metabolic energy expenditure savings and increases the symmetry in walking kinematics, compared to rigA-F. METHODS:Nine active UTA completed treadmill walking trials at zero gradient (at 0.8, 1.0, 1.2, 1.4, and 1.6 of customary walking speed) and for customary walking speed only, at two angles of decline (5° and 10°). The metabolic cost of locomotion was determined using respirometry. To gain insights into the source of any metabolic savings, 3D motion capture was used to determine segment kinematics, allowing body centre of mass dynamics (BCoM), differences in inter-limb symmetry and potential for energy recovery through pendulum-like motion to be quantified for each foot type. RESULTS:During both level and decline walking, use of a hyA-F compared to rigA-F significantly reduced the total mechanical work and increased the interchange between the mechanical energies of the BCoM (recovery index), leading to a significant reduction in the metabolic energy cost of locomotion, and hence an associated increase in locomotor efficiency (p < 0.001). It also increased inter-limb symmetry (medio-lateral and progression axes, particularly when walking on a 10° decline), highlighting the improvements in gait were related to a lessening of the kinematic compensations evident when using the rigA-F. CONCLUSIONS:Findings suggest that use of a DRF that incorporates a small passive hydraulic ankle device will deliver improvements in metabolic energy expenditure and kinematics and thus should provide clinically meaningful benefits to UTAs' everyday locomotion, particularly for those who are able to walk at a range of speeds and over different terrains

    BRIT1/MCPH1 Is Essential for Mitotic and Meiotic Recombination DNA Repair and Maintaining Genomic Stability in Mice

    Get PDF
    BRIT1 protein (also known as MCPH1) contains 3 BRCT domains which are conserved in BRCA1, BRCA2, and other important molecules involved in DNA damage signaling, DNA repair, and tumor suppression. BRIT1 mutations or aberrant expression are found in primary microcephaly patients as well as in cancer patients. Recent in vitro studies suggest that BRIT1/MCPH1 functions as a novel key regulator in the DNA damage response pathways. To investigate its physiological role and dissect the underlying mechanisms, we generated BRIT1−/− mice and identified its essential roles in mitotic and meiotic recombination DNA repair and in maintaining genomic stability. Both BRIT1−/− mice and mouse embryonic fibroblasts (MEFs) were hypersensitive to γ-irradiation. BRIT1−/− MEFs and T lymphocytes exhibited severe chromatid breaks and reduced RAD51 foci formation after irradiation. Notably, BRIT1−/− mice were infertile and meiotic homologous recombination was impaired. BRIT1-deficient spermatocytes exhibited a failure of chromosomal synapsis, and meiosis was arrested at late zygotene of prophase I accompanied by apoptosis. In mutant spermatocytes, DNA double-strand breaks (DSBs) were formed, but localization of RAD51 or BRCA2 to meiotic chromosomes was severely impaired. In addition, we found that BRIT1 could bind to RAD51/BRCA2 complexes and that, in the absence of BRIT1, recruitment of RAD51 and BRCA2 to chromatin was reduced while their protein levels were not altered, indicating that BRIT1 is involved in mediating recruitment of RAD51/BRCA2 to the damage site. Collectively, our BRIT1-null mouse model demonstrates that BRIT1 is essential for maintaining genomic stability in vivo to protect the hosts from both programmed and irradiation-induced DNA damages, and its depletion causes a failure in both mitotic and meiotic recombination DNA repair via impairing RAD51/BRCA2's function and as a result leads to infertility and genomic instability in mice

    Synergies, Strengths and Challenges: Findings on Community Capability from a Systematic Health Systems Research Literature Review

    Get PDF
    Background: Community capability is the combined influence of a community’s social systems and collective resources that can address community problems and broaden community opportunities. We frame it as consisting of three domains that together support community empowerment: what communities have; how communities act; and for whom communities act. We sought to further understand these domains through a secondary analysis of a previous systematic review on community participation in health systems interventions in low and middle income countries (LMICs). Methods: We searched for journal articles published between 2000 and 2012 related to the concepts of “community”, “capability/participation”, “health systems research” and “LMIC.” We identified 64 with rich accounts of community participation involving service delivery and governance in health systems research for thematic analysis following the three domains framing community capability. Results: When considering what communities have, articles reported external linkages as the most frequently gained resource, especially when partnerships resulted in more community power over the intervention. In contrast, financial assets were the least mentioned, despite their importance for sustainability. With how communities act, articles discussed challenges of ensuring inclusive participation and detailed strategies to improve inclusiveness. Very little was reported about strengthening community cohesiveness and collective efficacy despite their importance in community initiatives. When reviewing for whom communities act, the importance of strong local leadership was mentioned frequently, while conflict resolution strategies and skills were rarely discussed. Synergies were found across these elements of community capability, with tangible success in one area leading to positive changes in another. Access to information and opportunities to develop skills were crucial to community participation, critical thinking, problem solving and ownership. Although there are many quantitative scales measuring community capability, health systems research engaged with community participation has rarely made use of these tools or the concepts informing them. Overall, the amount of information related to elements of community capability reported by these articles was low and often of poor quality. Conclusions: Strengthening community capability is critical to ensuring that community participation leads to genuine empowerment. Our simpler framework to define community capability may help researchers better recognize, support and assess it
    corecore