105 research outputs found

    Sizes and shapes of 10-Ma Distal fall pyroclasts in the Ogallala gGroup, Nebraska

    Get PDF
    Size distributions of distal ashfall particles from correlated 10-Ma layers in Nebraska, measured using laser diffraction methods, are lognormal with mode diameters of ∼90 mm. This ashfall is ∼100% bubble-wall shards of rhyolite glass and apparently represents a distal ashfall from an eruption 1400 km away. Measured terminal velocities of these ash particles are 0.2–18 cm/s, consistent with Stokes Law settling of spherical particles with diameters of 9–50 mm. Surface area of the ash particles, measured with gas adsorption, is 20–30 times the surface area of equivalent Stokes spheres. These results highlight the effects of shape and atmospheric drag in distal ashfalls. They also highlight atmospheric transport and fallout of distal ashfall particles, because these deposits resemble many other ashfalls preserved in the Great Plains of North America throughout the Tertiary and Quaternary. Because the ashfalls preserve major mammalian death assemblages, they demonstrate that deposits with modes of optical diameters 1100 mm are still hazardous by aerodynamic definitions of lung disease risk and include particles substantially within hazardous PM10 ranges. The aerodynamically fine particle size may lead to substantial aeolian redistribution, causing local thicknesses of 12 m. Overall, the ashfall thicknesses observed are at least several times larger than would be expected based on exponential thinning from the volcano. Shape measurements of distal ash particles may be necessary to assess risk. The possible health risks in the central United States from a future rhyolitic eruption in the western United States may be significant

    Endothelial cell apoptosis in chronically obstructed and reperfused pulmonary artery

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Endothelial dysfunction is a major complication of pulmonary endarterectomy (PTE) that can lead to pulmonary edema and persistent pulmonary hypertension. We hypothesized that endothelial dysfunction is related to increased endothelial-cell (EC) death.</p> <p>Methods</p> <p>In piglets, the left pulmonary artery (PA) was ligated to induce lung ischemia then reimplanted into the main PA to reperfuse the lung. Animals sacrificed 5 weeks after ligation (n = 5), 2 days after reperfusion (n = 5), or 5 weeks after reperfusion (n = 5) were compared to a sham-operated group (n = 5). PA vasoreactivity was studied and eNOS assayed. EC apoptosis was assessed by TUNEL in the proximal and distal PA and by caspase-3 activity assay in the proximal PA. Gene expression of pro-apoptotic factors (thrombospondin-1 (Thsp-1) and plasminogen activator inhibitor 1 (PAI-1)) and anti-apoptotic factors vascular endothelial growth factor (VEGF) and basic fibroblast growth factor (bFGF) was investigated by QRT-PCR.</p> <p>Results</p> <p>Endothelium-dependent relaxation was altered 5 weeks after ligation (<it>p </it>= 0.04). The alterations were exacerbated 2 days after reperfusion (p = 0.002) but recovered within 5 weeks after reperfusion. EC apoptosis was increased 5 weeks after PA ligation (<it>p </it>= 0.02), increased further within 2 days after reperfusion (<it>p </it>< 0.0001), and returned to normal within 5 weeks after reperfusion. Whereas VEGF and bFGF expressions remained unchanged, TSP and PAI-1 expressions peaked 5 weeks after ligation (<it>p </it>= 0.001) and returned to normal within 2 days after reperfusion.</p> <p>Conclusion</p> <p>Chronic lung ischemia induces over-expression of pro-apoptotic factors. Lung reperfusion is followed by a dramatic transient increase in EC death that may explain the development of endothelial dysfunction after PE. Anti-apoptotic agents may hold considerable potential for preventing postoperative complications.</p

    Numerical simulation of blood flow and pressure drop in the pulmonary arterial and venous circulation

    Get PDF
    A novel multiscale mathematical and computational model of the pulmonary circulation is presented and used to analyse both arterial and venous pressure and flow. This work is a major advance over previous studies by Olufsen et al. (Ann Biomed Eng 28:1281–1299, 2012) which only considered the arterial circulation. For the first three generations of vessels within the pulmonary circulation, geometry is specified from patient-specific measurements obtained using magnetic resonance imaging (MRI). Blood flow and pressure in the larger arteries and veins are predicted using a nonlinear, cross-sectional-area-averaged system of equations for a Newtonian fluid in an elastic tube. Inflow into the main pulmonary artery is obtained from MRI measurements, while pressure entering the left atrium from the main pulmonary vein is kept constant at the normal mean value of 2 mmHg. Each terminal vessel in the network of ‘large’ arteries is connected to its corresponding terminal vein via a network of vessels representing the vascular bed of smaller arteries and veins. We develop and implement an algorithm to calculate the admittance of each vascular bed, using bifurcating structured trees and recursion. The structured-tree models take into account the geometry and material properties of the ‘smaller’ arteries and veins of radii ≥ 50 μ m. We study the effects on flow and pressure associated with three classes of pulmonary hypertension expressed via stiffening of larger and smaller vessels, and vascular rarefaction. The results of simulating these pathological conditions are in agreement with clinical observations, showing that the model has potential for assisting with diagnosis and treatment for circulatory diseases within the lung

    Development and Evaluation of Two Simple, Rapid Immunochromatographic Tests for the Detection of Yersinia pestis Antibodies in Humans and Reservoirs

    Get PDF
    Plague is due to the bacterium Yersinia pestis. It is accidentally transmitted to humans by the bite of infected fleas. Currently, approximately 20 developing countries with very limited infrastructure are still affected. A plague case was defined according to clinical, epidemiological and biological features. Rapid diagnosis and surveillance of the disease are essential for its control. Indeed, the delay of treatment is often rapidly fatal for patients and outbreaks may occur. Bubo aspirate is the most appropriate specimen in case of bubonic plague, but its collection is not always feasible. The main current biological approaches for the diagnosis of human plague are F1 antigen detection, serology for antibody detection by ELISA and Y. pestis isolation. The biological diagnosis of plague remains a challenge because the clinical signs are not specific. In this study, we developed some simple, rapid and affordable tests able to detect specific plague antibodies. These tests can be used as alternative methods for plague diagnosis in the field and for plague surveillance

    Dipstick Test for Rapid Diagnosis of Shigella dysenteriae 1 in Bacterial Cultures and Its Potential Use on Stool Samples

    Get PDF
    International audienceBACKGROUND: We describe a test for rapid detection of S. dysenteriae 1 in bacterial cultures and in stools, at the bedside of patients. METHODOLOGY/PRINCIPAL FINDINGS: The test is based on the detection of S. dysenteriae 1 lipopolysaccharide (LPS) using serotype 1-specific monoclonal antibodies coupled to gold particles and displayed on a one-step immunochromatographic dipstick. A concentration as low as 15 ng/ml of LPS was detected in distilled water and in reconstituted stools in 10 minutes. In distilled water and in reconstituted stools, an unequivocal positive reaction was obtained with 1.6×10⁶ CFU/ml and 4.9×10⁶ CFU/ml of S. dysenteriae 1, respectively. Optimal conditions to read the test have been determined to limit the risk of ambiguous results due to appearance of a faint yellow test band in some negative samples. The specificity was 100% when tested with a battery of Shigella and unrelated strains in culture. When tested on 328 clinical samples in India, Vietnam, Senegal and France by laboratory technicians and in Democratic Republic of Congo by a field technician, the specificity (312/316) was 98.7% (95% CI:96.6-99.6%) and the sensitivity (11/12) was 91.7% (95% CI:59.8-99.6%). Stool cultures and the immunochromatographic test showed concordant results in 98.4 % of cases (323/328) in comparative studies. Positive and negative predictive values were 73.3% (95% CI:44.8-91.1%) and 99.7% (95% CI:98-100%). CONCLUSION: The initial findings presented here for a simple dipstick-based test to diagnose S. dysenteriae 1 demonstrates its promising potential to become a powerful tool for case management and epidemiological surveys
    corecore